In this paper, a linearly chirped fiber Bragg grating (CFBG) inscribed in a microstructured polymer optical fiber (mPOF) has been demonstrated for detecting temperature profiles during thermal treatments. A CFBG of 10-mm length and 0.98-nm bandwidth has been inscribed in an mPOF fiber by means of a KrF laser and uniform phase mask. The CFBG has a high temperature sensitivity of -191.4 pm/°C. The CFBG has been used as a semi-distributed temperature sensor, capable of detecting the temperature profile along the grating length, for scenarios that account minimally invasive biomedical treatments. Two experiments have been designed to validate the CFBG temperature reconstruction, using a linear gradient, and a research-grade radiofrequency ablation setup to apply Gaussian-shaped temperature spatial profiles. The result is that the higher sensitivity of the CFBG supports the detection of spatially nonuniform temperature fields by means of spectral reconstruction.
In this paper, we present the design and experiments of a fiber Bragg grating (FBG) sensing network for nanoparticle-enhanced microwave ablation (MWA). MWA is an emerging minimally invasive treatment for cancer care, making use of a miniaturized applicator; it is possible to deliver a cytotoxic thermal treatment in situ with high spatial confinement. Cells' death is nearly instantaneous at 60 °C. The use of magnetite nanoparticles enhances the amount of ablated tissue, and reshapes the thermal distribution during the treatment. In order to measure the thermal maps (temperature as a function of space and time) instantaneously and in situ, a set of three arrays of five FBG sensors has been designed, mapping the thermal distribution of the tissue and estimating the ablated tissue in real time. Experiments carried out with different nanoparticle densities show that the extension of the ablated region is the highest for a density of 5 mg/mL. The results are displayed in the form of thermal maps, over the ablation plane.
Thermal ablation is achieved by delivering heat directly to tissue through a minimally invasive applicator. The therapy requires a temperature control between 50–100 °C since the mortality of the tumor is directly connected with the thermal dosimetry. Existing temperature monitoring techniques have limitations such as single-point monitoring, require costly equipment, and expose patients to X-ray radiation. Therefore, it is important to explore an alternative sensing solution, which can accurately monitor temperature over the whole ablated region. The work aims to propose a distributed fiber optic sensor as a potential candidate for this application due to the small size, high resolution, bio-compatibility, and temperature sensitivity of the optical fibers. The working principle is based on spatial multiplexing of optical fibers to achieve 3D temperature monitoring. The multiplexing is achieved by high-scattering, nanoparticle-doped fibers as sensing fibers, which are spatially separated by lower-scattering level of single-mode fibers. The setup, consisting of twelve sensing fibers, monitors tissue of 16 mm × 16 mm × 25 mm in size exposed to a gold nanoparticle-mediated microwave ablation. The results provide real-time 3D thermal maps of the whole ablated region with a high resolution. The setup allows for identification of the asymmetry in the temperature distribution over the tissue and adjustment of the applicator to follow the allowed temperature limits.
In this work, we report a fiber Bragg grating (FBG) sensing system for a real-time temperature monitoring during a high-intensity focused ultrasound (HIFU) treatment of breast fibroadenoma. Temperature monitoring of the HIFU procedure within the treated area contributes to a successful outcome of a thermal ablation procedure by providing a valid feedback to the clinician. The unique characteristics of the FBG sensors make them a valid alternative to traditional sensing techniques for a variety of biomedical applications, including thermotherapies. The experiments were conducted on ex vivo breast fibroadenoma tissues. Results confirm that proposed setup is able to perform multipoint temperature measurements and to distinguish between consecutive ultrasound pulses.