Ye Liu

Dr. Ye Liu

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZWZhihong Wu
Zhihong Wu
HPHaoying Pang
Haoying Pang
ZWZhuo Wang
Zhuo Wang
WFWenfeng Fan
Wenfeng Fan
LFLiu Feng
Liu Feng
WQWei Quan
Wei Quan
A new design method is proposed for a triaxial magnetic field gradient compensation system based on ferromagnetic boundary for atomic sensors. The target field method and the whale optimization algorithm are combined to design magnetic field coils thus transforming the complex analytical solution process into an intelligent optimization problem, while the boundary mirror method is introduced to decouple the coil from the magnetic shield. Magnetic field gradient coils are designed according to the coil design method and combined with the divergence and rotation theorems to form the triaxial gradients compensation system to suppress the magnetic field inhomogeneity in nine directions. The simulation and experimental results are compared with the results before and after compensation by using the box line diagram representing the statistics of the magnetic field deviation, in which the median value is reduced by 65.87% and 85.16%, the minimum by 99.66% and 77.76%, the 25 th quantile by 97.89% and 79.94%, and the 75th quantile by 91.52% and 85.17%, respectively.

20 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YFYang Fu
Yang Fu
WFWenfeng Fan
Wenfeng Fan
JRJiasen Ruan
Jiasen Ruan
YLYe Liu
Ye Liu
ZLZhenglong Lu
Zhenglong Lu
WQWei Quan
Wei Quan
The probe laser intensity working point optimization of the co- magnetometer operated in the spin-exchange relaxation-free (SERF) regime is studied theoretically and experimentally in this article. Based on the steady-state solution of the Bloch equation, the error equation of output signal considering the probe laser pumping effect is established. A method for real-time measuring the pumping rate of the probe laser on SERF co- magnetometer is presented. Combined with the measurement results, a method for quickly finding the optimal working point for the probe laser intensity is presented. The signal noise and long-term stability of the co- magnetometer under different probe laser intensities are measured experimentally to verify the accuracy of the law deduced from the theory. The results show that the pumping effect of the probe laser significantly reduces the signal-to-noise ratio of the co- magnetometer, which verifies the necessity of supplementing to error equation in this article. In addition, selecting an appropriate probe laser intensity working point can effectively reduce signal noise and bias instability of the SERF co- magnetometer.

22 April 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YLYe Liu
Ye Liu
WFWenfeng Fan
Wenfeng Fan
YFYang Fu
Yang Fu
HPHaoying Pang
Haoying Pang
HPHongyu Pei
Hongyu Pei
WQWei Quan
Wei Quan
A spin-exchange relaxation-free comagnetometer is a promising high-precision gyroscope as its inertial measurement sensitivity can rival that of existing technologies. The magnetic field error is one of the main factors that limits the long-term stability of the comagnetometer. The steady-state response and frequency response models of a K-Rb- 21 Ne comagnetometer are modified by considering the spin-exchange rate between the electron spins and the nuclear spins. The modified models are used to redefine the bias magnetic sensitivity of the K-Rb- 21 Ne comagnetometer and the suppression method of low-frequency magnetic field error is proposed. We demonstrate the magnetic drift suppression method proposed in the article by optimizing the cell temperature and pump laser power density. This study is helpful to improve the rotation measurement performance of the K-Rb- 21 Ne comagnetometer.

21 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
YLYe Liu
Ye Liu
HGHang Gao
Hang Gao
LMLongyan Ma
Longyan Ma
JQJiale Quan
Jiale Quan
WFWenfeng Fan
Wenfeng Fan
WQWei Quan
Wei Quan
With the widespread use of magneto-sensitive elements, magnetic shields are an important part of electronic equipment, ultra-sensitive atomic sensors, and in basic physics experiments. Particularly in Spin-exchange relaxation-free (SERF) co-magnetometers, the magnetic shield is an important component for maintaining the SERF state. However, the inherent noise of magnetic shield materials is an important factor limiting the measurement sensitivity and accuracy of SERF co-magnetometers. In this paper, both amorphous and nanocrystalline materials were designed and applied as the innermost magnetic shield of an SERF co-magnetometer. Magnetic noise characteristics of different amorphous and nanocrystalline materials used as the internal magnetic shielding layer of the magnetic shielding system were analyzed. In addition, the effects on magnetic noise due to adding aluminum to amorphous and nanocrystalline materials were studied. The experimental results show that compared with an amorphous material, a nanocrystalline material as the inner magnetic shield layer can effectively reduce the magnetic noise and improve the sensitivity and precision of the rotation measurement. Nanocrystalline material is very promising for inner shield composition in SERF co-magnetometers. Furthermore, its ultra-thin structure and low cost have significant application value in the miniaturization of SERF co-magnetometers.

3 November 2015 in Quantum Information Processing
Verified
Journal Article
Closed access
PDF file
WSWen-Yang Sun
Wen-Yang Sun
JSJiadong Shi
Jiadong Shi
DWDong Wang
Dong Wang
YLYe Liu
Ye Liu

4 September 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LMLongyan Ma
Longyan Ma
HPHaoying Pang
Haoying Pang
XGXiaohan Ge
Xiaohan Ge
YLYe Liu
Ye Liu
JQJiale Quan
Jiale Quan
WQWei Quan
Wei Quan
This study investigates the impact of magneto-optical misalignment on atomic spin responses in a spin-exchange relaxation-free (SERF) comagnetometer and proposes a method to measure and compensate for misalignment angles. By analyzing nuclear spin precession under varying bias magnetic field strengths, both the nuclear spin equivalent magnetic field (Bn) and the misalignment angle θ between the pump beam and the main magnetic field are extracted. To suppress the identified misalignment, a novel alignment technique based on periodic strong magnetic field pulses is introduced. This method enables rapid in-situ adjustment of the pump beam direction, thereby enhancing nuclear spin self-compensation and overall system performance. Experimental validation demonstrates that the proposed approach improves the suppression of transverse magnetic field interference, with a 43.2 % enhancement in magnetic response attenuation. Additionally, magneto-optical alignment optimization results in marked improvements in system stability and sensitivity: the Allan deviation at 100 s is reduced by 34 %, and the inertial measurement noise at 1 Hz decreases by 43.3 %, achieving a sensitivity of 3.56 × 10−6°/s/ √ Hz.