Mohammad Vajdi

Dr. Mohammad Vajdi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Renewable Energy
Verified
Journal Article
Closed access
TGTowhid Gholizadeh
Towhid Gholizadeh
Mohammad VajdiMohammad Vajdi
Mohammad Vajdi
HRHadi Rostamzadeh
Hadi Rostamzadeh


22 June 2023 in Entropy
Verified
Journal Article
Open access
PDF file
Kourosh VaferiKourosh Vaferi
Kourosh Vaferi
Mohammad VajdiMohammad Vajdi
Mohammad Vajdi
ASAmir Shadian
Amir Shadian
HAHamed Ahadnejad
Hamed Ahadnejad
FMFarhad Sadegh Moghanlou
Farhad Sadegh Moghanlou
HJHaleh Jafarzadeh
Haleh Jafarzadeh
The Tesla valve is a non-moving check valve used in various industries to control fluid flow. It is a passive flow control device that does not require external power to operate. Due to its unique geometry, it causes more pressure drop in the reverse direction than in the forward direction. This device’s optimal performance in heat transfer applications has led to the use of Tesla valve designs in heat sinks and heat exchangers. This study investigated a Tesla valve with unconventional geometry through numerical analysis. Two geometrical parameters and inlet velocity were selected as input variables. Also, the pressure drop ratio (PDR) and temperature difference ratio (TDR) parameters were chosen as the investigated responses. By leveraging numerical data, artificial neural networks were trained to construct precise prediction models for responses. The optimal designs of the Tesla valve for different conditions were then reported using the genetic algorithm method and prediction models. The results indicated that the coefficient of determination for both prediction models was above 0.99, demonstrating high accuracy. The most optimal PDR value was 4.581, indicating that the pressure drop in the reverse flow direction is 358.1% higher than in the forward flow direction. The best TDR response value was found to be 1.862.

17 October 2023 in Heliyon
Verified
Journal Article
Open access
Kourosh VaferiKourosh Vaferi
Kourosh Vaferi
Mohammad VajdiMohammad Vajdi
Mohammad Vajdi
SNSahar Nekahi
Sahar Nekahi
AHAmir Heydari
Amir Heydari
FMFarhad Sadegh Moghanlou
Farhad Sadegh Moghanlou
HJHaleh Jafarzadeh
Haleh Jafarzadeh
The current research focuses on optimizing the Nusselt number (Nu) and pressure drop (ΔP) in a bionic fractal heat sink. The artificial neural network (ANN) and response surface methodology (RSM) were used to model the thermos-hydraulic behavior of the MCHS. The aspect ratios of t/b (cavities' upper side to bottom side ratio) and h/b (cavities’ height to bottom side ratio), as well as the Reynolds number, were set as the independent variables in both ANN and RSM models. After finding the optimum state for the copper-made MCHS (containing the optimum design of the cavities along with the best applied velocity), different materials were tested and compared with the base case (heat sink made of copper). The obtained results indicated that both ANN and RSM models (with determination coefficient of 99.9 %) could exactly anticipate heat transfer and ΔP to a large extent. To achieve the optimal design of the microchannel heat sink (MCHS) with the objective of maximizing Nu and minimizing ΔP, the efficiency index of the device was evaluated. The analysis revealed that the highest efficiency index (1.070 by RSM and 1.067 by ANN methods) was attained when the aspect ratios were t/b = 0.2, h/b = 0.2, and the Reynolds number was 1000. Next, the effect of the different materials on heat sink performance was investigated, and it was observed that by reducing the thermal conductivity, the thermal resistance of the heat sink increased and its overall performance decreased.

24 March 2020 in BioImpacts
Verified
Journal Article
Open access
PDF file
ZHZahra Hajati
Zahra Hajati
FMFarhad Sadegh Moghanlou
Farhad Sadegh Moghanlou
Mohammad VajdiMohammad Vajdi
Mohammad Vajdi
SRSeyed Esmail Razavi
Seyed Esmail Razavi
SMSomaieh Matin
Somaieh Matin
Introduction: Venous valves are a type of one-way valves which conduct blood flow toward the heart and prevent its backflow. Any malfunction of these organs may cause serious problems in the circulatory system. Numerical simulation can give us detailed information and point to point data such as velocity, wall shear stress, and von Mises stress from veins with small diameters, as obtaining such data is almost impossible using current medical devices. Having detailed information about fluid flow and valves' function can help the treatment of the related diseases. Methods: In the present work, the blood flow through a venous valve considering the flexibility of the vein wall and valve leaflets is investigated numerically. The governing equations of fluid flow and solid domain are discretized and solved by the Galerkin finite element method. Results: The obtained results showed that the blood velocity increases from inlet to the leaflets and then decreases passing behind the valve. A pair of vortices and the trapped region was observed just behind the valves. These regions have low shear stresses and are capable of sediment formation. Conclusion: The von Mises stress which is a criterion for the breakdown of solid materials was obtained. It was also observed that a maximum value occurred at the bottom of the leaflets.

31 August 2023 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
KVKourosh Vaferi
Kourosh Vaferi
SNSanam Nekahi
Sanam Nekahi
Mohammad VajdiMohammad Vajdi
Mohammad Vajdi
FMFarhad Sadegh Moghanlou
Farhad Sadegh Moghanlou
NBNilgun Baydogan
Nilgun Baydogan
MAMehdi Shahedi Asl
Mehdi Shahedi Asl