Jiping Ge

Dr. Jiping Ge

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2014 in Frontiers of Structural and Civil Engineering
Verified
Journal Article
Closed access
PDF file
ZWZhiqiang Wang
Zhiqiang Wang
JGJiping Ge
Jiping Ge
HWHongyi Wei
Hongyi Wei

21 May 2018 in Frontiers of Structural and Civil Engineering
Verified
Journal Article
Closed access
PDF file
JGJiping Ge
Jiping Ge
MSM. Saiid Saiidi
M. Saiid Saiidi
SVSebastian Varela
Sebastian Varela

14 August 2023 in Engineering Structures
Verified
Journal Article
Closed access
PZPenghui Zhang
Penghui Zhang
ZWZhiqiang Wang
Zhiqiang Wang
JGJiping Ge
Jiping Ge
XYXingfei Yan
Xingfei Yan
SLSide Liu
Side Liu

1 January 2018 in Shock and Vibration
Verified
Journal Article
Open access
JGJiping Ge
Jiping Ge
MSM. Saiid Saiidi
M. Saiid Saiidi
The seismic performance of the SR99 Bridge with conventional and advanced details in Seattle, Washington, was studied via a nonlinear, time history analysis of a multidegree of freedom model. The bridge consists of three spans supported on two single‐column piers and will be the first built bridge in the world in which superelastic shape memory alloy (SMA) and engineered cementitious composite (ECC) are implemented to reduce damage at plastic hinges and minimize residual displacements. Existing finite‐element formulations in the finite‐element software OpenSees are used to capture the response of the advanced materials used in the bridge. The earthquake induced by strike‐slip fault was assumed to produce a surface rupture across the SR99 Bridge. The effect of the rupture was modeled by a static, differential ground displacement in the fault‐parallel direction across the rupture. The synthetic suite of scaled bidirectional near‐fault ground motions used in the analysis contains common near‐fault features including a directivity pulse in the fault‐normal direction and a fling step in the fault‐parallel direction. Comparisons are made on behavior of two different bridge types. The first is a conventional reinforced concrete bridge and the second is a bridge with Nickel‐Titanium (NiTi) SMA reinforcing bar at the plastic hinge zone and ECC in the whole column. Fault‐parallel near‐fault earthquakes typically exhibit a static permanent ground displacement caused by the relative movement of the two sides of the fault. When the fault is located between piers, the pier shows a higher demand. Fault‐normal analysis results show effectiveness of the innovative interventions on the bridges in providing excellent recentering capabilities with minimal damage to the columns. But the maximum drift computed in the SMA bridge is slightly higher than reinforced concrete (RC) bridges, contributed by comparatively low stiffness of the superelastic SMA bars compared to the steel reinforcing bars.

21 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
JGJiping Ge
Jiping Ge
LLLuqi Lai
Luqi Lai
SLSide Liu
Side Liu
XYXingfei Yan
Xingfei Yan
Socket connection need a groove reserved in the cap to accommodate a bridge pier, which greatly weaken the vertical bearing capacity of the cap. The conventional treatment measure is to increase the thickness of the cap, and the corresponding cost will increase. The measures to enhance the vertical bearing capacity of socket caps without increasing the thickness of the cap were discussed in this paper, including a rough interface at the bottom of the pier, additional hanging bars, high-strength grouting material in the seam, and large-diameter metal corrugated pipes, etc. Based on a previous test, the finite element analysis of the vertical bearing capacity of pile caps with new socket connections was carried out. The analysis parameters included the construction method, steel bar diameter in the bottom of the cap, socket depth, thickness of the bottom plate, pile length, and friction coefficient, etc. The bearing capacity M–N relation of the full-scale model was also analyzed. Research indicated the vertical bearing capacity of the cap is mainly provided by rough interfaces, the bottom plate, and the additional hanging bars, and the contribution of the three parts was about 40%, 34%, and 26%; the vertical bearing capacity was proportional to the areas of steel bars on the cap and the thickness of the bottom plate, and was inversely proportional to the length of the pile. To obtain the vertical bearing capacity of the overall cast-in-place plan for the socket cap, the thickness of the cap needs to be increased by 27%. At last, a design formula for the calculation of the vertical bearing capacity was proposed.

17 January 2026 in Transportation Research Record: Journal of the Transportation Research Board
Verified
Journal Article
Closed access
JGJiping Ge
Jiping Ge
SGSheng Gong
Sheng Gong
SXShuai Xie
Shuai Xie
To study the mechanical properties of large-diameter rebar grouting sleeves (GS) in prefabricated bridge piers, 40 mm diameter GS specimens were designed and subjected to high-stress cyclic and large-deformation cyclic axial tension tests. The influences of the anchorage length and loading method on the failure mode, structural performance, and bond strength were analyzed. The results show that the specimens are in an elastic state under high-stress loading and exhibit plastic characteristics under large-deformation loading. As the anchorage length decreases, the failure mode changes from rebar fracture to slip failure, and an anchorage length of 7d can meet the seismic requirements. The eccentricity of the rebar has no significant effect on the ultimate bearing capacity. The test reveals that the average bond stress decreases with the increase of the anchorage length, and the longitudinal and transverse strain values on the sleeve surface decrease from the middle to the ends. A calculation formula for the bond strength between the rebar and the grouting material with a safety factor was established through data fitting. The research confirms that the large-diameter rebar GS connection has reliable seismic performance and can be used as an effective connection method for prefabricated bridge piers.