A label-free and selective aptamer beacon-based Love-wave biosensing device was developed for prostate specific antigen (PSA) detection. The device consists of the following parts: LiTaO3 substrate with SiO2 film as wave guide layer, two set of inter-digital transducers (IDT), gold film for immobilization of the biorecongniton layer and a polydimethylsiloxane (PDMS) microfluidic channels. DNA aptamer, or “artificial antibody”, was used as the specific biorecognition probe for PSA capture. Some nucleotides were added to the 3'-end of the aptamer to form a duplex with the 3'-end, turning the aptamer into an aptamer-beacon. Taking advantage of the selective target-induced assembly changes arising from the “aptamer beacon”, highly selective and specific detection of PSA was achieved. Furthermore, PDMS microfluidic channels were designed and fabricated to realize automated quantitative sample injection. After optimization of the experimental conditions, the established device showed good performance for PSA detection between 10 ng/mL to 1 μg/mL, with a detection limit of 10 ng/mL. The proposed sensor might be a promising alternative for point of care diagnostics.
Artificial nano‐ and microswimmers are promising as versatile nanorobots for applications in biomedicine, environmental chemistry, and materials science. Herein, a hybrid micromotor containing a conjugated polymer (poly(3,4‐ethylenedioxythiophene) (PEDOT), and a catalytic structure composed of platinum (Pt) synthesized using a template‐supported electrochemical deposition process is reported. The movement of this PEDOT/Pt micromotor is characterized under chemical power generated by hydrogen peroxide catalysis, and acoustic power generated by surface acoustic waves (SAWs). The acoustic radiation force acting between the bubbles, the secondary Bjerknes force, is shown to increase the micromotor speed. The movement of the micromotor is precisely controllable using the acoustic field, providing excellent response time and reproducibility over a wide dynamic range. A theoretical model is developed to understand and predict the micromotor propulsion under the hybrid chemical and acoustic power. Predicted micromotor speeds are in excellent agreement with experiment as a function of peroxide fuel concentration, SAW field strength, and SAW frequency. The model allows for design of micromotor geometries and acoustic field strengths to achieve desired speed with excellent on/off control.
Achieving low power consumption and high sensitivity is a major obstacle in realizing the potential of surface acoustic wave (SAW) devices in portable sensing applications. In this paper, we demonstrate that an optimal combination of a microcavity structure filled with a low acoustic impedance material in the delay path combined with a suitable wave guide lowers power consumption substantially and improves sensitivity. 3-D finite-element method (FEM) simulations were employed to systematically evaluate the effect of various filling and waveguide materials for ~100 MHz devices in ST quartz. Based on the simulated device designs, trends in device performance, and ease of fabrication, SAW sensors were fabricated in ST quartz with tantalum filling of the microcavity array along with an optimal SiO 2 wave guide to achieve improvements on the order of 5 dB in insertion loss and nearly ten times the sensitivity compared with an SAW device without these modifications. This paper allows for the possibility of designing and realizing robust SAW sensors for detection at concentration levels of relevance to clinical diagnosis, i.e., sub-ng to ng/mL levels.
Love wave sensors have been widely used for sensing applications. In this work, we introduce the theoretical analysis of the monolayer and double-layer waveguide Love wave sensors. The velocity, particle displacement and energy distribution of Love waves were analyzed. Using the variations of the energy repartition, the sensitivity coefficients of Love wave sensors were calculated. To achieve a higher sensitivity coefficient, a thin gold layer was added as the second waveguide on top of the silicon dioxide (SiO2) waveguide–based, 36 degree–rotated, Y-cut, X-propagating lithium tantalate (36° YX LiTaO3) Love wave sensor. The Love wave velocity was significantly reduced by the added gold layer, and the flow of wave energy into the waveguide layer from the substrate was enhanced. By using the double-layer structure, almost a 72-fold enhancement in the sensitivity coefficient was achieved compared to the monolayer structure. Additionally, the thickness of the SiO2 layer was also reduced with the application of the gold layer, resulting in easier device fabrication. This study allows for the possibility of designing and realizing robust Love wave sensors with high sensitivity and a low limit of detection.