Biqin Dong

Prof. Dr. Biqin Dong

Academy for Engineering and Technology, Fudan University, Shanghai, China

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2015 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
YZYafeng Zhang
Yafeng Zhang
BDBiqin Dong
Biqin Dong
ACAng Chen
Ang Chen
XLXiaohan Liu
Xiaohan Liu
LSLei Shi
Lei Shi
JZJian Zi
Jian Zi

24 June 2013 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
LSLei Shi
Lei Shi
YZYafeng Zhang
Yafeng Zhang
BDBiqin Dong
Biqin Dong
TZTianrong Zhan
Tianrong Zhan
XLXiaohan Liu
Xiaohan Liu
JZJian Zi
Jian Zi

28 March 2014 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HLHao Li
Hao Li
BDBiqin Dong
Biqin Dong
ZZZhen Zhang
Zhen Zhang
HZHao F. Zhang
Hao F. Zhang
CSCheng Sun
Cheng Sun
Photoacoustic microscopy (PAM) does not rely on contrast agent to image the optical absorption contrast in biological tissue. It is uniquely suited for measuring several tissue physiological parameters, such as hemoglobin oxygen saturation, that would otherwise remain challenging. Researchers are designing new clinical diagnostic tools and multimodal microscopic systems around PAM to fully unleash its potential. However, the sizeable and opaque piezoelectric ultrasonic detectors commonly used in PAM impose a serious constraint. Our solution is a coverslip-style optically transparent ultrasound detector based on a polymeric optical micro-ring resonator (MRR) with a total thickness of 250 μm. It enables highly-sensitive ultrasound detection over a wide receiving angle with a bandwidth of 140 MHz, which corresponds to a photoacoustic saturation limit of 287 cm−1, at an estimated noise-equivalent pressure (NEP) of 6.8 Pa. We also established a theoretical framework for designing and optimizing the MRR for PAM.

1 September 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
BDBiqin Dong
Biqin Dong
CSCheng Sun
Cheng Sun
HZHao F. Zhang
Hao F. Zhang
Objective: Photoacoustic (PA) imaging emerges as a unique tool to study biological samples based on optical absorption contrast. In PA imaging, piezoelectric transducers are commonly used to detect laser-induced ultrasonic waves. However, they typically lack adequate broadband sensitivity at ultrasonic frequency higher than 100 MHz, whereas their bulky size and optically opaque nature cause technical difficulties in integrating PA imaging with conventional optical imaging modalities. To overcome these limitations, optical methods of ultrasound detection were developed and shown their unique applications in PA imaging. Methods: We provide an overview of recent technological advances in optical methods of ultrasound detection and their applications in PA imaging. A general theoretical framework describing sensitivity, bandwidth, and angular responses of optical ultrasound detection is also introduced. Results: Optical methods of ultrasound detection can provide improved detection angle and sensitivity over significantly extended bandwidth. In addition, its versatile variants also offer additional advantages, such as device miniaturization, optical transparency, mechanical flexibility, minimal electrical/mechanical crosstalk, and potential noncontact PA imaging. Conclusion: The optical ultrasound detection methods discussed in this review and their future evolution may play an important role in PA imaging for biomedical study and clinical diagnosis.

25 July 2016 in Nature Communications
Verified
Journal Article
Open access
PDF file
BDBiqin Dong
Biqin Dong
LALuay Almassalha
Luay Almassalha
BUBen E. Urban
Ben E. Urban
TNThe-Quyen Nguyen
The-Quyen Nguyen
SKSatya Khuon
Satya Khuon
HZHao F. Zhang
Hao F. Zhang
Traditional photon localization microscopy analyses only the spatial distributions of photons emitted by individual molecules to reconstruct super-resolution optical images. Unfortunately, however, the highly valuable spectroscopic information from these photons have been overlooked. Here we report a spectroscopic photon localization microscopy that is capable of capturing the inherent spectroscopic signatures of photons from individual stochastic radiation events. Spectroscopic photon localization microscopy achieved higher spatial resolution than traditional photon localization microscopy through spectral discrimination to identify the photons emitted from individual molecules. As a result, we resolved two fluorescent molecules, which were 15 nm apart, with the corresponding spatial resolution of 10 nm—a four-fold improvement over photon localization microscopy. Using spectroscopic photon localization microscopy, we further demonstrated simultaneous multi-colour super-resolution imaging of microtubules and mitochondria in COS-7 cells and showed that background autofluorescence can be identified through its distinct emission spectra.

27 August 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
FLF. Liu
F. Liu
BDBiqin Dong
Biqin Dong
XLX. H. Liu
X. H. Liu
YZY. M. Zheng
Y. M. Zheng
JZJ. Zi
J. Zi
The elytra of longhorn beetles Tmesisternus isabellae show iridescent golden coloration which stems from long and flat scales imbricated densely on the elytral surface. The scales are able to change coloration from golden in the dry state to red in the wet state with water absorption. Structural characterizations revealed that the iridescent coloration of scales originates from a multilayer in the scale interior. Measurements on both water contact angle and chemical composition indicated that scales are hydrophilic. The change in scale coloration to red in the wet state is due to both the swelling of the multilayer period and water infiltration. The unraveled structural color change and its strategy may not only help us get insight into the biological functionality of structural coloration but also inspire the designs of artificial photonic devices.