Aiming at improving the effectiveness and real‐time performance of the fault detection of the photovoltaic (PV) array under different outdoor conditions, a novel method based on Grubbs criterion and local outlier factor (G‐LOF) method is proposed in this study. The simulation model of the PV array is built to obtain the reference current of each PV string. The local outlier factor (LOF) is a ratio of the average local reachability density of sample neighbourhoods relative to its local reachability density. In this study, the LOF is used to quantify the abnormality by comparing the measured current and the simulated reference current. To reduce the false alarm probability of LOF, the Grubbs criterion is utilised as the test criterion to detect the abnormality of PV strings and it is merged with the LOF to derivate the G‐LOF. The experiments of partial shading, open‐circuit fault and short‐circuit fault of PV modules are implemented in sunny and cloudy days. Experimental results verify that the proposed G‐LOF method can sensitively detect above abnormalities, especially can detect the slight performance reduction caused by the partial shading or faults.
21 January 2023 in Energy Conversion and Management
The large scale application of the photovoltaic (PV) systems is significantly beneficial to the mitigation of energy crisis. The quality and performance of PV systems directly influence the energy yield. It is necessary to establish more scientific and effective methods to maximize the energy yield. In this paper, the concept of health status is proposed to describe the performance of PV systems within a certain period of time. A health status based performance evaluation model is built by the Gaussian mixture models (GMM) and the empirical mode decomposition (EMD). Then, the health index (HI) of PV array is defined. Under the outdoor ambient conditions, the proposed model can sensitively detect the slight performance reduction caused by faults or partial shadings of the PV array in real-time. At last, the proposed method is verified by the simulations and experiments. Experimental results show that on the sunny day the average daily HI is 1.2 and the average performance ratio (PR) is 0.85, which both show the PV array is healthy. When one of the PV modules in the PV array is partially shaded, the PR is still approximate 0.9. However, the calculated HI is greater than the threshold and the fault is reported. The results indicate that the proposed method can sensitively identify pseudo health status that cannot be identified by the PR. The proposed evaluation method based on health status provides an alternative option to assess the performance of the PV systems. Combining with the PR, the comprehensive performance of the PV systems can be reflected more accurately.
8 October 2018 in International Journal of Green Energy
This paper presents a novel global maximum power point tracking (MPPT) method based on the sorting particle swarm optimizer (PSO). At first, the output characteristics of photovoltaic (PV) array under the partial shading conditions are analyzed. As an artificial intelligence algorithm, the sorting PSO is proposed for global MPPT of PV array under partial shading conditions. The principle of the proposed algorithm is illustrated in detail. Second, a stand-alone PV system based on Z-source inverter (ZSI) is simulated to validate the proposed global MPPT method. Then, the experiments are implemented based on the established ZSI. Compared with the conventional PSO for MPPT, simulation and experimental results both reveal that the proposed global MPPT method based on the sorting PSO can reduce the fluctuation of voltage of PV array during MPPT. Simulation results reveal that 61.53% and 51.81% energy consumption during MPPT is reduced under two different typical partial shading conditions. The proposed MPPT method can also track the global maximum power point more rapidly. Approximately 21.21–39.96% time consumptions during MPPT are saved.