Cesare Tiengo

Prof. Dr. Cesare Tiengo

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Elena StoccoElena Stocco
Elena Stocco
Silvia BarbonSilvia Barbon
Silvia Barbon
AEAron Emmi
Aron Emmi
CTCesare Tiengo
Cesare Tiengo
Veronica MacchiVeronica Macchi
Veronica Macchi
Andrea PorzionatoAndrea Porzionato
Andrea Porzionato
In peripheral nerve injuries (PNI) with substance loss, where tensionless end-to-end suture is not achievable, the positioning of a graft is required. Available options include autografts (e.g., sural nerve, medial and lateral antebrachial cutaneous nerves, superficial branch of the radial nerve), allografts (Avance®; human origin), and hollow nerve conduits. There are eleven commercial hollow conduits approved for clinical, and they consist of devices made of a non-biodegradable synthetic polymer (polyvinyl alcohol), biodegradable synthetic polymers (poly(DL-lactide-ε-caprolactone); polyglycolic acid), and biodegradable natural polymers (collagen type I with/without glycosaminoglycan; chitosan; porcine small intestinal submucosa); different resorption times are available for resorbable guides, ranging from three months to four years. Unfortunately, anatomical/functional nerve regeneration requirements are not satisfied by any of the possible alternatives; to date, focusing on wall and/or inner lumen organization/functionalization seems to be the most promising strategy for next-generation device fabrication. Porous or grooved walls as well as multichannel lumens and luminal fillers are the most intriguing options, eventually also including the addition of cells (Schwann cells, bone marrow-derived, and adipose tissue derived stem cells) to support nerve regeneration. This review aims to describe common alternatives for severe PNI recovery with a highlight of future conduits.

7 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RFRiccardo Fratti
Riccardo Fratti
NMNiccolo Marini
Niccolo Marini
Manfredo AtzoriManfredo Atzori
Manfredo Atzori
HMHenning Müller
Henning Müller
CTCesare Tiengo
Cesare Tiengo
Franco BassettoFranco Bassetto
Franco Bassetto
Advancements in neural network approaches have enhanced the effectiveness of surface Electromyography (sEMG)-based hand gesture recognition when measuring muscle activity. However, current deep learning architectures struggle to achieve good generalization and robustness, often demanding significant computational resources. The goal of this paper was to develop a robust model that can quickly adapt to new users using Transfer Learning. We propose a Multi-Scale Convolutional Neural Network (MSCNN), pre-trained with various strategies to improve inter-subject generalization. These strategies include domain adaptation with a gradient-reversal layer and self-supervision using triplet margin loss. We evaluated these approaches on several benchmark datasets, specifically the NinaPro databases. This study also compared two different Transfer Learning frameworks designed for user-dependent fine-tuning. The second Transfer Learning framework achieved a 97% F1 Score across 14 classes with an average of 1.40 epochs, suggesting potential for on-site model retraining in cases of performance degradation over time. The findings highlight the effectiveness of Transfer Learning in creating adaptive, user-specific models for sEMG-based prosthetic hands. Moreover, the study examined the impacts of rectification and window length, with a focus on real-time accessible normalizing techniques, suggesting significant improvements in usability and performance.

20 March 2023 in Life
Verified
Journal Article
Open access
PDF file
GAGiovanna Albertin
Giovanna Albertin
Laura AstolfiLaura Astolfi
Laura Astolfi
Caterina FedeCaterina Fede
Caterina Fede
ESEDI SIMONI
EDI SIMONI
MCMartina Contran
Martina Contran
CARLA STECCOCARLA STECCO
CARLA STECCO
Recently, the superficial fascia has been recognized as a specific anatomical structure between the two adipose layers—the superficial adipose tissue (SAT) and the deep adipose tissue (DAT). The evaluation of specific characteristics of cells, fibers, blood circulation, and innervation has shown that the superficial fascia has a clear and distinct anatomical identity, but knowledge about lymphatic vessels in relation to the superficial fascia has not been described. The aim of this study was to evaluate the presence of lymphatic vessels in the hypodermis, with a specific focus on the superficial fascia and in relation to the layered subdivision of the subcutaneous tissue into SAT and DAT. Tissue specimens were harvested from three adult volunteer patients during abdominoplasty and stained with D2-40 antibody for the lymphatic endothelium. In the papillary dermis, a huge presence of lymphatic vessels was highlighted, parallel to the skin surface and embedded in the loose connective tissue. In the superficial adipose tissue, thin lymphatic vessels (mean diameter of 11.6 ± 7.71 µm) were found, close to the fibrous septa connecting the dermis to the deeper layers. The deep adipose tissue showed a comparable overall content of lymphatic vessels with respect to the superficial layer; they followed the blood vessel and had a larger diameter. In the superficial fascia, the lymphatic vessels showed higher density and a larger diameter, in both the longitudinal and transverse directions along the fibers, as well as vessels that intertwined with one another, forming a rich network of vessels. This study demonstrated a different distribution of the lymphatic vessels in the various subcutaneous layers, especially in the superficial fascia, and the demonstration of the variable gauge of the vessels leads us to believe that they play different functional roles in the collection and transport of interstitial fluid—important factors in various surgical and rehabilitation fields.

14 December 2020 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
Andrea AngeliniAndrea Angelini
Andrea Angelini
CTCesare Tiengo
Cesare Tiengo
RSRegina Sonda
Regina Sonda
ABAntonio Berizzi
Antonio Berizzi
Franco BassettoFranco Bassetto
Franco Bassetto
Pietro RuggieriPietro Ruggieri
Pietro Ruggieri
Background and Objectives. Wide surgical resection is a relevant factor for local control in sarcomas. Plastic surgery is mandatory in demanding reconstructions. We analyzed patients treated by a multidisciplinary team to evaluate indications and surgical approaches, complications and therapeutic/functional outcomes. Methods. We analyzed 161 patients (86 males (53%), mean age 56 years) from 2006 to 2017. Patients were treated for their primary tumor (120, 75.5%) or after unplanned excision/recurrence (41, 25.5%). Sites included lower limbs (36.6%), upper limbs (19.2%), head/neck (21.1%), trunk (14.9%) and pelvis (8.1%). Orthoplasty has been considered for flaps (54), skin grafts (42), wide excisions (40) and other procedures (25). Results. At a mean follow-up of 5.3 years (range 2–10.5), patients continuously showed no evidence of disease (NED) in 130 cases (80.7%), were alive with disease (AWD) in 10 cases (6.2%) and were dead with disease (DWD) in 21 cases (13.0%). Overall, 62 patients (38.5%) developed a complication (56 minor (90.3%) and 6 major (9.7%)). Flap loss occurred in 5/48 patients (10.4%). The mean Musculoskeletal Tumor Society (MSTS) and Toronto Extremity Salvage Score (TESS) was 74.8 ± 14 and 79.1 ± 13, respectively. Conclusions. Orthoplasty is a combined approach effective in management of sarcoma patients, maximizing adequate surgical resection, limb salvaging and functional recovery. One-stage reconstructions are technically feasible and are not associated with increased risk of complications.

1 December 2010 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
BAB. Azzena
B. Azzena
AAA. Amabile
A. Amabile
CTCesare Tiengo
Cesare Tiengo

Verified
Journal Article
Open access
PDF file
Caterina FedeCaterina Fede
Caterina Fede
LPLucia Petrelli
Lucia Petrelli
Carmelo PirriCarmelo Pirri
Carmelo Pirri
CTCesare Tiengo
Cesare Tiengo
Raffaele De CaroRaffaele De Caro
Raffaele De Caro
CARLA STECCOCARLA STECCO
CARLA STECCO
The recent findings showed that the superficial fascia is a fibrous layer in the middle of hypodermis, richly innervated and vascularized, and more complex than so far demonstrated. This study showed the presence of mast cells in the superficial fascia of the human abdomen wall of three adult volunteer patients (mean age 42 ± 4 years; 2 females, 1 male), by Toluidine Blue and Safranin-O stains and Transmission Electron Microscopy. Mast cells are distributed among the collagen bundles and the elastic fibers, near the vessels and close to the nerves supplying the tissue, with an average density of 20.4 ± 9.4/mm2. The demonstration of the presence of mast cells in the human superficial fascia highlights the possible involvement of the tissue in the inflammatory process, and in tissue healing and regeneration processes. A clear knowledge of this anatomical structure of the hypodermis is fundamental for a good comprehension of some fascial dysfunctions and for a better-targeted clinical practice.