The vibrating mesh nebulizer (VMN) has gained popularity for its compactness and noiselessness. This study investigates the impact of different air inlet structures on the deposition fraction (DF) of droplets generated by VMNs in an idealized mouth–throat (MT) airway model. Three homemade VMNs with semi-circular inlet, symmetrical four-inlet, and multiple-orifice inlet structures were evaluated through simulations and experiments. The changes in droplet DF of 0.9% w/v concentration of nebulized sodium chloride (NaCl) droplets as a function of inertial parameters were acquired under different inhalation flow conditions. Additionally, flow field distributions in models with different inlet structures were analyzed at a steady inspiratory flow rate of 15 L/min. The results indicate that optimizing the VMN’s air inlet structure significantly enhances droplet delivery efficiency. The multiple–orifice inlet structure outperformed the other designs, directing the airflow from the inlet position to the center of the mouthpiece and then into the oral cavity, achieving a DF of up to 20% at an inhalation flow rate of 15 L/min. The region of high airflow velocity between the mouthpiece and oral cavity proved to be a favorable VMN inlet optimization, reducing direct droplet–wall collisions and improving delivery efficiency. These findings offer insights for VMN design and optimization to enhance pulmonary drug delivery effectiveness and therapeutic outcomes.
The surgery outcomes after fixing nasal airway obstruction (NAO) are sometimes not satisfactory in improving ventilations of airflow. A case study is presented in this paper with computational fluid dynamics applied to determine the key factors for successful septoplasty plans for a patient with a deviated nasal septum. Specifically, airflow, as well as particle transport and deposition were predicted in a pre-surgery nasal cavity model reconstructed from patient-specific Computer Tomography (CT) images and two post-surgery nasal cavity models (i.e., VS1 and VS2) with different virtual surgery plans A and B. Plan A corrected the deviated septal cartilage, the perpendicular plate of the ethmoid bone, vomer, and nasal crest of the maxilla. Plan B further corrected the obstruction in the nasal vestibule and caudal nasal septal deviation based on Plan A. Simulations were performed in the three nose-to-throat airway models to compare the airflow velocity distributions and local particle depositions. Numerical results indicate that the VS2 model has a better improvement in airflow allocation between the two sides than the VS1 model. In addition, the deposition fractions in the VS2 model are lower than that in both the original and VS1 models, up to 25.32%. The better surgical plan (i.e., Plan B) reduces the particle deposition on the convex side, but slightly increases the deposition on the concave side. However, the overall deposition in the nasal cavity is reduced.
Nebulizer is one of inhalation therapy’s most widely used aerosol generation devices. Nowadays, the vibrating mesh nebulizer has become popular owing to its compactness and noiselessness. In this study, an experimental system is proposed to measure the deposition fraction (DF) of nebulized sodium chloride (NaCl) droplets in an idealized mouth-throat airway model. The results show that before the DF increases to 58.6% with an increasing flow rate to 60 L/min, there is a decrease in DF from 42.4% to 15.5% when the inhalation flow rate increases from 15 to 22.5 L/min for a normal saline solution. These results substantially differ from the conclusions of dry powder or particle experiments and simulations, which monotonously increases with increasing inhalation flow rate. This suggests that droplet evaporation during aerosol generation and transport in the airway plays an important role. The experiment also showed that droplets generated from solutions with a higher NaCl concentration have higher DFs.