Ozzy Mermut

Prof. Ozzy Mermut


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2025 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
CHCoral Hillel
Coral Hillel
SCSarah Collins
Sarah Collins
APAmanpreet Parihar
Amanpreet Parihar
OMOzzy Mermut
Ozzy Mermut
CBChristopher Barrett
Christopher Barrett
LRLinda Reven
Linda Reven
The hydrazone form of two azo food dyes, as revealed by NMR with DFT, predominates in solution and solid chitosan films, having important implications for development of these dye-polymer films into light-triggered recyclable bioplastics.

1 November 2024 in Communications Chemistry
Verified
Journal Article
Open access
PDF file
CHCoral Hillel
Coral Hillel
SRSara Rough
Sara Rough
CBChristopher Barrett
Christopher Barrett
WPWilliam J. Pietro
William J. Pietro
OMOzzy Mermut
Ozzy Mermut
Many studies of azobenzene photoswitches are carried out in polar aprotic solvents as a first principles characterization of thermal isomerization. Among the most convenient polar aprotic solvents are chlorinated hydrocarbons, such as DCM. However, studies of azobenzene thermal isomerization in such solvents have led to spurious, inconclusive, and irreproducible results, even when scrupulously cleaned and dried, a phenomenon not well understood. We present the results of a comprehensive investigation into the root cause of this problem. We explain how irradiation of an azopyridine photoswitch with UV in DCM acts not just as a trigger for photoisomerization, but protonation of the pyridine moiety through photodecomposition of the solvent. Protonation markedly accelerates the thermal isomerization rate, and DFT calculations demonstrate that the singlet-triplet rotation mechanism assumed for many azo photoswitches is surprisingly abolished. This study implies exploitative advantages of photolytically-generated protons and finally explains the warning against using chlorinated solvent with UV irradiation in isomerization experiments.

8 December 2020 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
SKSperydon Koumarianos
Sperydon Koumarianos
RKRohith Kaiyum
Rohith Kaiyum
CBChristopher Barrett
Christopher Barrett
NMNeal Madras
Neal Madras
OMOzzy Mermut
Ozzy Mermut
We study here the role of polyelectrolyte chain length, that is number of repeat units (mers), in the competitive adsorption of a simple model polyanion, poly(acrylic acid), onto 85 nm spherical silica particles capped with a model polycation, poly(allylamine hydrochloride). Performing fluorescence spectroscopy experiments, we measured chain-length dependence of dilute aqueous polyelectrolyte adsorption, at full surface coverage, onto an oppositely charged polyelectrolyte overtop spherical silica nanoparticles (10−3 g L−1). Preferential adsorption was determined by comparing the characteristic fluorescence intensities of the two fluorophore-labeled and narrowly disperse polyacrylic acid samples (NMA–PAA450k and Dan–PAA2k) of 450k- and 2k-molecular weight (6250- and 28-mers), respectively. To compare and validate experimental results, a lattice model was developed for computing the probabilities of the different arrangements of two polymer chain lengths of polyacrylic acid on the surface of the silica nanosphere. We then determined which numbers of long and short adsorbed chains corresponded to the most configurations in our model. Both spectroscopic experiment results and the combinatorial model demonstrated that there is an entropic preference for complete adsorption of the longer 450k polyacrylic acid chain vs. 2k. This study provides insights on entropy driven chain-length dependence of polyelectrolyte adsorption onto spherical nanoparticle surfaces for directing and optimizing their layer-by-layer self-assembly in organic films.

29 March 2022 in Medical Physics
Verified
Journal Article
Open access
RKRohith Kaiyum
Rohith Kaiyum
CSChristopher W. Schruder
Christopher W. Schruder
OMOzzy Mermut
Ozzy Mermut
ARAlexandra Rink
Alexandra Rink
Purpose: Radiochromic material used in recent commercial films has been suggested as a candidate for in vivo dosimetry because of its dose sensitivity, real‐time response, and atomic composition. It was observed that its sensitive material, lithium pentacosa‐10,12‐diynoate (LiPCDA), can have two distinct forms, with main absorbance peaks at ∼635 and ∼674 nm. The spectrum of the latter is similar to that of pentacosa‐10,12‐diynoic acid (PCDA) used in the commercial predecessor, obtained through desiccation of the commercial film. Water was suggested to be a part of the crystal structure and thus its presence or absence would affect dosimetric parameters. The objective of this study is to: (a) investigate how desiccated commercial films compared to the native form in terms of macroscopic crystal structure, dose–response, signal linearity, and post‐exposure kinetics; (b) demonstrate proof‐of‐concept that the two versions can be combined into one optical dosimeter and measured simultaneously.Methods: Commercial radiochromic film, EBT‐3, was desiccated for 10 days at 45°C. Using a 6 MV LINAC beam and standard setup of 100 Source to Axis Distance (SAD), 10 cm × 10 cm field size, and 1.5 cm depth, commercial and desiccated films were irradiated to 50, 100, 200, 500, 1000, 2000, 3000 cGy and the latter to 4000, 5000, and 7000 cGy. A custom phantom equipped with optical fibers for real‐time read‐out was used for all measurements. Absorbance spectra were collected at ∼1 Hz before, during, and after irradiation. Data were collected for ∼1 h after the end of irradiation for 200 cGy experiments. The radiation‐induced change in optical density (∆OD) was calculated with a 10 nm band around the primary absorbance peak. The post‐exposure percent optical density change was calculated and compared to ∆OD at the end of irradiation. Both commercial and desiccated films were also irradiated and measured simultaneously as proof‐of‐concept for using two materials within one optical path. For electron microscopy imaging, active materials from commercial and desiccated films were imaged on a scanning electron microscope at an accelerating voltage of 10 kV.Results: Scanning electron microscope images showed that desiccated film was similar in topographical structure to the commercial EBT‐3 form. It maintained a non‐linear ∆OD with dose but resulted in ∼1/3 signal compared to the commercial film. Evaluation of post‐exposure response showed significantly lower percent increase in ∆OD for desiccated film initially, with no statistically significant difference at 1 h after the end of irradiation. Combining both films and simultaneously measuring their absorbance illustrated that the two absorbance peaks were identifiable and resolvable to allow for an independent determination of dose from each.Conclusions: Water is implicated in the crystal structure of the EBT‐3 radiochromic film, with its removal through desiccation affecting both dosimetric and spectroscopic characteristics of the material. The two forms of radiochromic material (with and without water) are spectrally resolvable allowing for independent dose determination from each, opening up possibilities for dose measurements at different locations along a single fiber.

2 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
WPWilliam J. Pietro
William J. Pietro
OMOzzy Mermut
Ozzy Mermut
A portable and sensitive time-resolved biosensor for capturing very low intensity light emission is a promising avenue to study plant delayed fluorescence. These weak emissions provide insight on plant health and can be useful in plant science as well as in the development of accurate feedback indicators for plant growth and yield in applications of agricultural crop cultivation. A field-based delayed fluorescence device is also desirable to enable monitoring of plant stress response to climate change. Among basic techniques for the detection of rapidly fluctuating low intensity light is photon counting. Despite its vast utility, photon counting techniques often relying on photomultiplier tube (PMT) technology, having restricted use in agricultural and environment measurements of plant stress outside of the laboratory setting, mainly due to the prohibitive cost of the equipment, high voltage nature, and the complexity of its operation. However, recent development of the new generation solid-state silicon photomultiplier (SiPM) single photon avalanche diode array has enabled the availability of high quantum efficiency, easy-to-operate, compact, photon counting systems which are not constrained to sophisticated laboratories, and are accessible owing to their low-cost. In this contribution, we have conceived, fabricated and validated a novel SiPM-based photon counting device with integrated plug-and-play excitation LED, all housed inside a miniaturized sample chamber to record weak delayed fluorescence lifetime response from plant leaves subjected to varying temperature condition and drought stress. Findings from our device show that delayed fluorescence reports on the inactivation to the plant’s photosystem II function in response to unfavorable acute environmental heat and cold shock stress as well as chronic water deprivation. Results from our proof-of-concept miniaturized prototype demonstrate a new, simple and effective photon counting instrument is achieved, one which can be deployed in-field to rapidly and minimally invasively assess plant physiological growth and health based on rapid, ultra-weak delayed fluorescence measurements directly from a plant leaf.

21 October 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
RBRobert B. Brown
Robert B. Brown
SDSuzie Dufour
Suzie Dufour
PDPascal Deladurantaye
Pascal Deladurantaye
NBNolwenn Le Bouch
Nolwenn Le Bouch
PGPascal Gallant
Pascal Gallant
OMOzzy Mermut
Ozzy Mermut
Photoacoustic sensing can be a powerful technique to obtain real-time feedback of laser energy dose in treatments of biological tissue. However, when laser therapy uses pulses with microsecond duration, they are not optimal for photoacoustic pressure wave generation. This study examines a programmable fiber laser technique using pulse modulation in order to optimize the photoacoustic feedback signal to noise ratio (SNR) in a context where longer laser pulses are employed, such as in selective retinal therapy. We have demonstrated with a homogeneous tissue phantom that this method can yield a greater than seven-fold improvement in SNR over non-modulated square pulses of the same duration and pulse energy. This technique was further investigated for assessment of treatment outcomes in leporine retinal explants by photoacoustic mapping around the cavitation-induced frequency band.