Shuo Yan

Dr. Shuo Yan

STEM|School of Engineering, RMIT University, Melbourne, VIC 3001, Australia

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2014 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Shuo YanShuo Yan
Shuo Yan
STSiew Chong Tan
Siew Chong Tan
CLChi-Kwan Lee
Chi-Kwan Lee
BCBalarko Chaudhuri
Balarko Chaudhuri
SHS. Y. Ron Hui
S. Y. Ron Hui
Electric springs have been used previously in stabilizing mains voltage fluctuation in power grid fed by intermittent renewable energy sources. This paper describes a new three-phase electric spring circuit and its new operation in reducing power imbalance in the three-phase power system of a building. Based on government energy use data for tall buildings, the electric loads are classified as critical and noncritical loads so that building energy model can be developed. The proposed electric spring is connected in series with the noncritical loads to form a new generation of smart loads. A control scheme for such smart loads to reduce power imbalance within the building's electric power system has been evaluated initially with an experimental prototype and then in a system simulation study. The results have confirmed the effectiveness of the new three-phase electric springs in reducing power imbalance and voltage fluctuation, making the building loads adaptive to internal load changes and external mains voltage changes.

2 April 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Shuo YanShuo Yan
Shuo Yan
YYYongheng Yang
Yongheng Yang
SHS. Y. Hui
S. Y. Hui
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Starting from the principle of instantaneous power theory, this article explores various direct power control (DPC) strategies for three-phase two-level pulsewidth modulation (PWM) converters. After summarizing the fundamental power formula of PWM rectifiers, this article studies the operating principle of the conventional table-based approach and its related improvements. It further looks into the advanced counterparts employing space vector modulation and different nonlinear control strategies. The emphasis is put on the prevailing predictive DPC. Besides, the voltage-sensorless and robust DPC methods based on the virtual flux concept and the state observer or estimator are investigated. Critical issues, including the sample delay, constant switching frequency, duty cycle optimization, objective function, and unbalanced operation are examined.

5 September 2016 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Shuo YanShuo Yan
Shuo Yan
CLChi-Kwan Lee
Chi-Kwan Lee
TYTianbo Yang
Tianbo Yang
KMKwan-Tat Mok
Kwan-Tat Mok
STSiew Chong Tan
Siew Chong Tan
SHS. Y. Ron Hui
S. Y. Ron Hui
This paper presents the first hardware implementation and control of an electric spring based on a back-to-back converter configuration. Because of its ability to provide both active and reactive power compensation, this back-to-back electric spring (ES-B2B) can substantially extend the operating range of the original version of the electric spring (ES-1) and provide enhanced voltage support and suppression functions. The hardware system and control of the ES-B2B have been successfully developed and tested. The experimental results have confirmed the effectiveness of the ES-B2B in supporting and suppressing the mains voltage. Particularly, the voltage suppression ability of the ES-B2B is superior over that of ES-1. The use of ES-B2B in a simulation study of a weak power grid has also been conducted. The ES-B2B has been found to be highly effective in mitigating voltage fluctuation caused by intermittent renewable power generation.

8 December 2016 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Open access
Shuo YanShuo Yan
Shuo Yan
STSiew Chong Tan
Siew Chong Tan
CLChi-Kwan Lee
Chi-Kwan Lee
BCBalarko Chaudhuri
Balarko Chaudhuri
SHS. Y. Ron Hui
S. Y. Ron Hui
Electric spring (ES) was originally proposed as a distributed demand-side management technology for making noncritical loads adaptive to the availability of intermittent renewable power generation. The second generation of ES, fed with batteries (ES-2) and associated with a noncritical load, can form a new kind of combined smart load and distributed energy storage technology for smart grids. With its four-quadrant operation, ES-2 is able to offer ancillary grid services in addition to its major functions of voltage and frequency regulation. This paper presents the operating principles and the input current control of ES-2 for power quality improvement such as power factor correction and harmonics reduction. The operating principles and the proposed input current control have been verified with the experimental results obtained from a small-scale power grid. Another weak single-phase power system fed by intermittent wind power is set up to prove the combined operation of ES-2 for power quality improvement and ES-1 (ES with capacitor storage) for voltage stabilization. The experimental results show that ES-2 with input current control can carry out power quality improvement as its ancillary function.

14 January 2016 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
XLXiao Luo
Xiao Luo
CLChi Kwan Lee
Chi Kwan Lee
WNWai Man Ng
Wai Man Ng
Shuo YanShuo Yan
Shuo Yan
BCBalarko Chaudhuri
Balarko Chaudhuri
SHShu Yuen Ron Hui
Shu Yuen Ron Hui
This paper describes how a large-scale ice-thermal storage can be turned into a smart load for fast voltage control and demand-side management in power systems with intermittent renewable power, while maintaining its existing function of load shaving. The possibility of modifying a conventional thermal load has been practically demonstrated in a refrigerator using power electronics technology. With the help of an electric spring, the modified thermal load can reduce power imbalance in buildings while providing active and reactive power compensation for the power grid. Based on practical data, a building energy model incorporating a large-scale ice-thermal storage system has been successfully used to demonstrate the advantageous demand-response features using computer simulation of both grid connected and isolated power systems. The results indicate the potential of using ice-thermal storage in tall buildings in reducing voltage and frequency fluctuations in weak power grids.

10 March 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Minghao WangMinghao Wang
Minghao Wang
Shuo YanShuo Yan
Shuo Yan
STSiew Chong Tan
Siew Chong Tan
SHShu Yuen (Ron) Hui
Shu Yuen (Ron) Hui
DC electric springs (DCES) are emerging technologies for the (i) regulation of mains voltage against the intermittent renewable generations and (ii) harmonic cancellation in dc microgrids. When conventional converter topologies (e.g., half-bridge or full-bridge converter) are adopted as DCES, the battery storage of the DCES has to process both the dc power and the ac harmonic power. The pulsating ac power can severely reduce the lifetime of the battery. To address this issue, a hybrid-DCES (H-DCES) is proposed in this paper to perform (i) and (ii) in a decoupled manner. With a modified topology and control method, the H-DCES can divert the ac current to the ground and retains the function of manipulating noncritical load for dc voltage regulation. The immediate benefits of this H-DCES are the reduction of storage capacity and a prolonged lifetime of the battery. Both the operating principle and the mathematical model of the proposed H-DCES are analyzed in this paper. A prototype of the H-DCES is practically tested in a 48-V dc grid. The experimental results show that the H-DCES can realize the decoupled operation of dc voltage regulation and harmonic cancellation. Simulation studies further demonstrate that the H-DCES requires less storage capacity than its counterparts.