Non-contact vibration measurements are relevant for non-invasively characterizing the mechanical behavior of structures. This paper presents a novel methodology for full-field vibrational analysis at high frequencies using the three-dimensional digital image correlation technique combined with the projection of a speckle pattern. The method includes stereo calibration and image processing routines for accurate three-dimensional data acquisition. Quantitative analysis allows the extraction of several deformation parameters, such as the cross-correlation coefficients, shape and intensity, as well as the out-of-plane displacement fields and mode shapes. The potential of the methodology is demonstrated on an Unmanned Aerial Vehicle wing made of composite material, followed by experimental validation with reference accelerometers. The results obtained with the projected three-dimensional digital image correlation show a percentage of error below 5% compared with the measures of accelerometers, achieving, therefore, high sensitivity to detect the dynamic modes in structures made of composite material.
To develop a novel algorithm based on ray tracing, simulated visual performance and through-focus optimization for an accurate intraocular lens (IOL) power calculation. Custom-developed algorithms for ray tracing optimization (RTO) were used to combine the natural corneal higher-order aberrations (HOAs) with multiple sphero-cylindrical corrections in 210 higher order statistical eye models for developing keratoconus. The magnitude of defocus and astigmatism producing the maximum Visual Strehl was considered as the optimal sphero-cylindrical target for IOL power calculation. Corneal astigmatism and the RMS HOAs ranged from − 0.64 ± 0.35D and 0.10 ± 0.04 μm (0-months) to − 3.15 ± 1.38D and 0.82 ± 0.47 μm (120-months). Defocus and astigmatism target was close to neutral for eyes with low amount of HOAs (0 and 12-months), where 91.66% of eyes agreed within ± 0.50D in IOL power calculation (RTO vs. SRK/T). However, corneas with higher amounts of HOAs presented greater visual improvement with an optimized target. In these eyes (24- to 120-months), only 18.05% of eyes agreed within ± 0.50D (RTO vs. SRK/T). The power difference exceeded 3D in 42.2% while the cylinder required adjustments larger than 3D in 18.4% of the cases. Certain amounts of lower and HOAs may interact favourably to improve visual performance, shifting therefore the refractive target for IOL power calculation.
Intraocular lens (IOL) power calculation is normally performed using theoretical Gaussian formulas. Paraxial calculation renders clinically acceptable outcomes in normal eyes with regular corneal shape and optics but leads to refractive error whenever the cornea is irregular in terms of anterior surface shape or anterior to posterior curvature proportions. The most prevalent conditions are keratoconus, keratoplasty, or corneas that have undergone refractive surgery, especially with old techniques. In this chapter, a more robust calculation methodology is proposed based on a three-dimensional model of the cornea constructed from tomographic data. Optical calculations are done by exact ray tracing, overcoming the limitations of the paraxial constraints and managing adequately the effect of higher-order aberrations. Image quality metrics that correlates with subjective vision will be used as a target to determine the best IOL sphere and cylinder power.
To develop a novel algorithm based on ray tracing, simulated visual performance and through-focus optimization for an accurate intraocular lens (IOL) power calculation. Custom-developed algorithms for ray tracing optimization (RTO) were used to combine the natural corneal higher-order aberrations (HOAs) with multiple sphero-cylindrical corrections in 210 higher order statistical eye models for developing keratoconus. The magnitude of defocus and astigmatism producing the maximum Visual Strehl was considered as the optimal sphero-cylindrical target for IOL power calculation. Corneal astigmatism and the RMS HOAs ranged from − 0.64 ± 0.35D and 0.10 ± 0.04 µm (0-months) to -3.15 ± 1.38D and 0.82 ± 0.47 µm (120-months). Defocus and astigmatism target was close to neutral for eyes with low amount of HOAs (0 and 12-months), where 91.66% of eyes agreed within ± 0.50D in IOL power calculation (RTO vs. SRK/T). However, corneas with higher amounts of HOAs presented greater visual improvement with an optimized target. In these eyes (24- to 120-months), only 18.05% of eyes agreed within ± 0.50D (RTO vs. SRK/T). The power difference exceeded 3D in 42.2% while the cylinder required adjustments larger than 3D in 18.4% of the cases. Certain amounts of lower and HOAs may interact favourably to improve visual performance, shifting therefore the refractive target for IOL power calculation.