JINYI LI

Dr. JINYI LI

Tiangong University
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZDZhenhui Du
Zhenhui Du
SZShuai Zhang
Shuai Zhang
JINYI LIJINYI LI
JINYI LI
NGNan Gao
Nan Gao
KTKebin Tong
Kebin Tong
The vast majority of gaseous chemical substances exhibit fundamental rovibrational absorption bands in the mid-infrared spectral region (2.5–25 μm), and the absorption of light by these fundamental bands provides a nearly universal means for their detection. A main feature of optical techniques is the non-intrusive in situ detection of trace gases. We reviewed primarily mid-infrared tunable laser-based broadband absorption spectroscopy for trace gas detection, focusing on 2008–2018. The scope of this paper is to discuss recent developments of system configuration, tunable lasers, detectors, broadband spectroscopic techniques, and their applications for sensitive, selective, and quantitative trace gas detection.

26 August 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
JINYI LIJINYI LI
JINYI LI
ZYZiwei Yu
Ziwei Yu
ZDZhenhui Du
Zhenhui Du
YJYue Ji
Yue Ji
CLChang Liu
Chang Liu
Remote chemical detection in the atmosphere or some specific space has always been of great interest in many applications for environmental protection and safety. Laser absorption spectroscopy (LAS) is a highly desirable technology, benefiting from high measurement sensitivity, improved spectral selectivity or resolution, fast response and capability of good spatial resolution, multi-species and standoff detection with a non-cooperative target. Numerous LAS-based standoff detection techniques have seen rapid development recently and are reviewed herein, including differential absorption LiDAR, tunable laser absorption spectroscopy, laser photoacoustic spectroscopy, dual comb spectroscopy, laser heterodyne radiometry and active coherent laser absorption spectroscopy. An update of the current status of these various methods is presented, covering their principles, system compositions, features, developments and applications for standoff chemical detection over the last decade. In addition, a performance comparison together with the challenges and opportunities analysis is presented that describes the broad LAS-based techniques within the framework of remote sensing research and their directions of development for meeting potential practical use.

12 October 2022 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JINYI LIJINYI LI
JINYI LI
XYXue Yang
Xue Yang
LLLianhui Li
Lianhui Li
ZWZebin Wang
Zebin Wang
LHLingui He
Lingui He
ZDZhenhui Du
Zhenhui Du

1 February 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JINYI LIJINYI LI
JINYI LI
CZChenge Zhang
Chenge Zhang
YWYingying Wei
Yingying Wei
ZDZhenhui Du
Zhenhui Du
FSFushuang Sun
Fushuang Sun
CLChang Liu
Chang Liu

1 November 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
BXBo Xiong
Bo Xiong
ZDZhenhui Du
Zhenhui Du
JINYI LIJINYI LI
JINYI LI
Optical fringes constitute one of the major obstacles in the gas detection based on wavelength modulation spectroscopy (WMS). In order to suppress optical fringes, a convenient method of modulation index optimization was presented, using the signal-fringe ratio as a criterion. In addition to suppressing optical fringes, the optimized modulation index enables the detection of gas absorption. This method was demonstrated in a WMS based oxygen sensor. By comparing the sensor performances with and without the use of the optimized modulation index, we showed that the optical fringes are reduced by using the optimized modulation index; furthermore, the system stability and detection limit are improved. More specifically, the long-term fluctuation of the sensor measurement is dramatically reduced by a factor of 8, and a detection limit of as low as 120 ppm (with effective optical path length of 32 cm and integral time of 2.6 s), characterized by the Allan variance, was derived. This method can be applied in other existing WMS systems without the need for additional devices or complex algorithms and has the potential to be used in both laboratory and industrial settings.

14 August 2015 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
JINYI LIJINYI LI
JINYI LI
ZDZhenhui Du
Zhenhui Du
YAYing An
Ying An