Cariton Kubwabo

Dr. Cariton Kubwabo

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Science of The Total Environment
Verified
Journal Article
Closed access
XFXinghua Fan
Xinghua Fan
CKCariton Kubwabo
Cariton Kubwabo
PRPat Rasmussen
Pat Rasmussen
FWFang Wu
Fang Wu


28 April 2013 in Indoor Air
Verified
Journal Article
Closed access
PDF file
CKCariton Kubwabo
Cariton Kubwabo
PRPat Rasmussen
Pat Rasmussen
XFX. Fan
X. Fan
IKI. Kosarac
I. Kosarac
FWF. Wu
F. Wu
SKS. L. Kuchta
S. L. Kuchta
Phthalates have been used extensively as plasticizers to improve the flexibility of polymers, and they also have found many industrial applications. They are ubiquitous in the environment and have been detected in a variety of environmental and biological matrices. The goal of this study was to develop a method for the determination of 17 phthalate esters in house dust. This method involved sonication extraction, sample cleanup using solid phase extraction, and isotope dilution GC/MS/MS analysis. Method detection limits (MDLs) and recoveries ranged from 0.04 to 2.93 μg/g and from 84 to 117%, respectively. The method was applied to the analysis of phthalates in 38 paired household vacuum samples (HD) and fresh dust (FD) samples. HD and FD samples compared well for the majority of phthalates detected in house dust. Data obtained from 126 household dust samples confirmed the historical widespread use of bis(2‐ethylhexyl) phthalate (DEHP), with a concentration range of 36 μg/g to 3840 μg/g. Dibutyl phthalate (DBP), benzyl butyl phthalate (BzBP), diisononyl phthalate (DINP), and diisodecyl phthalate (DIDP) were also found in most samples at relatively high concentrations. Another important phthalate, diisobutyl phthalate (DIBP), was detected at a frequency of 98.4% with concentrations ranging from below its MDL of 0.51 μg/g to 69 μg/g.

1 May 2013 in Chemosphere
Verified
Journal Article
Closed access
CKCariton Kubwabo
Cariton Kubwabo
IKIvana Kosarac
Ivana Kosarac
KLKaela Lalonde
Kaela Lalonde

6 September 2010 in Journal of Environmental Monitoring
Verified
Journal Article
Closed access
PDF file
XFXinghua Fan
Xinghua Fan
CKCariton Kubwabo
Cariton Kubwabo
PRPat Rasmussen
Pat Rasmussen
HJHeather Jones-Otazo
Heather Jones-Otazo
An integrated analytical method for the simultaneous determination of five parabens (methyl-, ethyl-, propyl-, butyl-, and benzyl-), triclosan, and methyl triclosan in indoor house dust was developed based on gas chromatographic-mass spectrometric technique (GC/MS). Analytes were extracted from dust samples by sonication. After sample cleanup by solid-phase extraction (SPE), the extracts were derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) and then analyzed by gas chromatography coupled with ion trap mass spectrometry operated in multiple reaction monitoring (MRM) mode. For quantitation, isotope-labelled internal standards were used for each corresponding target analyte. Only 0.05 g of dust sample was needed for the analysis. Method detection limits ranged from 6.5 to 10 ng/g, and absolute recoveries from 74% to 92%. The developed method demonstrated good repeatability and reproducibility, with relative standard deviations (RSDs) less than 16% for all the analytes. The analytes were determined in dust samples collected using two vacuum sampling methods from 63 Canadian homes: a sample of fresh or “active” dust (FD) collected using a Pullman-Holt vacuum sampler, and a composite sample taken from the household vacuum cleaner (HD). Methyl paraben, propyl paraben, and triclosan were detected in all HD and FD samples. HD samples yielded median values for methyl paraben, propyl paraben, and triclosan of 1080, 463, and 378 ng/g, respectively, which were comparable to the FD sample medians of 1120, 618 and 571 ng/g. Ethyl paraben was detected at frequencies of 89% in FD and 73% in HD samples, with median values of 52 and 25 ng/g, respectively. Butyl paraben was detected at frequencies of 44% in FD and 75% in HD samples, with median values of <10 and 59 ng/g, respectively. Benzyl paraben and methyl triclosan were not detected in any of the samples collected by either method. Samples collected according to the fresh dust protocol agreed with the household vacuum samples 90% of the time. Widely scattered concentration levels were observed for target analytes from this preliminary set of 63 Canadian samples, which suggests a wide variability in Canadian household exposures to these chemicals.

3 September 2021 in Current Research in Food Science
Verified
Journal Article
Open access
SSShabana Siddique
Shabana Siddique
GZGong Zhang
Gong Zhang
KCKaela Coleman
Kaela Coleman
CKCariton Kubwabo
Cariton Kubwabo
Bisphenol A (BPA) is used as a monomer in a number of consumer products, including baby bottles and sippy cups. Some jurisdictions around the world (including Canada) have regulated the production, advertising or selling polycarbonate baby bottles with BPA. Following the ban, makers have opted for alternative materials to BPA [named BPA analogues, BPAAs], which may not be as safe as promoted. The objective of this project was to conduct a migration study in baby bottles and sippy cups, and analyze 16 BPAAs, as a follow-up on the BPA migration study conducted by Health Canada in 2009. Baby bottles (20 brands) and sippy cups (13 brands) were tested for migration of BPAAs. The most commonly detected analytes in baby bottles were BPS, BPA, BPF, BPAF, BPM and BPTMC with detection frequency (DF) of more than 50%. In sippy cups, only BPA, BPS and BPF were frequently detected. The mean concentration of BPA in baby bottle leachate was 31.5 ng/L in water simulant whereas a 1.4-fold increase was seen in 50% EtOH simulant. Similarly, a 1.4-fold increase was seen in the mean concentration of BPS in 50% EtOH simulant, when compared to the mean concentration of 2.33 ng/L in water simulant. Increasing median concentration was observed for BPA as the ethanol content of the simulant increased (water<10% EtOH<50% EtOH). The concentration of BPS and BPA was higher in sippy cups than that in their matched brand of baby bottles with the 50% EtOH simulant. Although most of the target analytes were detected in baby bottles, their concentrations were low and no migration was observed for any of the analytes with increasing incubation time. Therefore, it is likely that known BPA analogues are not present in the polymers used in the manufacture of most of the baby bottle brands sold in Canada.