Yinghua Zhao

Dr. Yinghua Zhao


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2021 in European Radiology
Verified
Journal Article
Closed access
PDF file
HCHaimei Chen
Haimei Chen
XZXiao Zhang
Xiao Zhang
XWXiaohong Wang
Xiaohong Wang
XQXianyue Quan
Xianyue Quan
YDYu Deng
Yu Deng
YZYinghua Zhao
Yinghua Zhao


10 October 2024 in Cancer Imaging
Verified
Journal Article
Open access
PDF file
LSLiwen Song
Liwen Song
CLChuanpu Li
Chuanpu Li
LTLilian Tan
Lilian Tan
MWMenghong Wang
Menghong Wang
XCXiaqing Chen
Xiaqing Chen
YZYinghua Zhao
Yinghua Zhao
Background: Accurately classifying primary bone tumors is crucial for guiding therapeutic decisions. The National Comprehensive Cancer Network guidelines recommend multimodal images to provide different perspectives for the comprehensive evaluation of primary bone tumors. However, in clinical practice, most patients’ medical multimodal images are often incomplete. This study aimed to build a deep learning model using patients’ incomplete multimodal images from X-ray, CT, and MRI alongside clinical characteristics to classify primary bone tumors as benign, intermediate, or malignant. Methods: In this retrospective study, a total of 1305 patients with histopathologically confirmed primary bone tumors (internal dataset, n = 1043; external dataset, n = 262) were included from two centers between January 2010 and December 2022. We proposed a Primary Bone Tumor Classification Transformer Network (PBTC-TransNet) fusion model to classify primary bone tumors. Areas under the receiver operating characteristic curve (AUC), accuracy, sensitivity, and specificity were calculated to evaluate the model’s classification performance. Results: The PBTC-TransNet fusion model achieved satisfactory micro-average AUCs of 0.847 (95% CI: 0.832, 0.862) and 0.782 (95% CI: 0.749, 0.817) on the internal and external test sets. For the classification of benign, intermediate, and malignant primary bone tumors, the model respectively achieved AUCs of 0.827/0.727, 0.740/0.662, and 0.815/0.745 on the internal/external test sets. Furthermore, across all patient subgroups stratified by the distribution of imaging modalities, the PBTC-TransNet fusion model gained micro-average AUCs ranging from 0.700 to 0.909 and 0.640 to 0.847 on the internal and external test sets, respectively. The model showed the highest micro-average AUC of 0.909, accuracy of 84.3%, micro-average sensitivity of 84.3%, and micro-average specificity of 92.1% in those with only X-rays on the internal test set. On the external test set, the PBTC-TransNet fusion model gained the highest micro-average AUC of 0.847 for patients with X-ray + CT. Conclusions: We successfully developed and externally validated the transformer-based PBTC-Transnet fusion model for the effective classification of primary bone tumors. This model, rooted in incomplete multimodal images and clinical characteristics, effectively mirrors real-life clinical scenarios, thus enhancing its strong clinical practicability.


22 February 2023 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
WLWenya Li
Wenya Li
RLRongtian Li
Rongtian Li
QYQiang Ye
Qiang Ye
YZYiming Zou
Yiming Zou
XLXing Lu
Xing Lu
YZYinghua Zhao
Yinghua Zhao

18 February 2019 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JLJin Liu
Jin Liu
ANAmin Nazaran
Amin Nazaran
YMYajun Ma
Yajun Ma
HCHaimei Chen
Haimei Chen
YZYanchun Zhu
Yanchun Zhu
YZYinghua Zhao
Yinghua Zhao
The collagen density is not detected in the patellar tendon (PT), posterior cruciate ligament (PCL), and anterior cruciate ligament (ACL) in clinic. We assess the technical feasibility of three-dimension multiecho fat saturated ultrashort echo time cones (3D FS-UTE-Cones) acquisitions for single- and bicomponent T2⁎analysis of bound and free water pools in PT, PCL, and ACL in clinic. The knees of five healthy volunteers and six knee joint samples from cadavers were scanned via 3D multiecho FS-UTE-Cones acquisitions on a clinical scanner. Single-component fitting of T2⁎Mand bicomponent fitting of short T2⁎(T2⁎S), long T2⁎(T2⁎L), short T2⁎fraction (Frac_S), and long T2⁎fraction (Frac_L) were performed within tendons and ligaments. Our results showed that biexponential fitting was superior to single-exponential fitting in PT, PCL, and ACL. For knee joint samples, there was no statistical difference among all data in PT, PCL, and ACL. For volunteers, all parameters of bicomponent fitting were statistically different across PT, PCL, and ACL, except for T2⁎S, T2⁎L, and T2⁎Mresulting in flawed measurements due to the magic angle effect. 3D multiecho FS-UTE-Cones acquisition allows high resolution T2⁎mapping in PT, PCL, and ACL of keen joint samples and PT and PCL of volunteers. The T2⁎values and their fractions can be characterized by bicomponent T2⁎analysis that is superior to single-component T2⁎analysis, except for ACL of volunteers.