Zhongjun Mo

Prof. Zhongjun Mo

National Research Center for Rehabilitation Technical Aids, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Journal of Dentistry
Verified
Journal Article
Closed access
JLJingyin Liu
Jingyin Liu
SPShaoxia Pan
Shaoxia Pan
JDJing Dong
Jing Dong
ZMZhongjun Mo
Zhongjun Mo
YFYubo Fan
Yubo Fan
HFHailan Feng
Hailan Feng

14 May 2014 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
CDChengfei Du
Chengfei Du
ZMZhongjun Mo
Zhongjun Mo
STShan Tian
Shan Tian
LWLizhen Wang
Lizhen Wang
JFJie Fan
Jie Fan
Yubo FanYubo Fan
Yubo Fan

15 April 2015 in Spine
Verified
Journal Article
Closed access
ZMZhongjun Mo
Zhongjun Mo
YZYanbin Zhao
Yanbin Zhao
CDChengfei Du
Chengfei Du
YSYu Sun
Yu Sun
MZMing Zhang
Ming Zhang
Yubo FanYubo Fan
Yubo Fan
Study Design. A 3-dimensional finite element investigation. Objective. To compare the biomechanical performances of different rotation centers (RCs) in the prevalent artificial cervical discs. Summary of Background Data. Various configurations are applied in artificial discs. Design parameters may influence the biomechanics of implanted spine. The RC is a primary variation in the popular artificial discs. Methods. Implantation of 5 prostheses was simulated at C5–C6 on the basis of a validated finite element cervical model (C3–C7). The prostheses included ball-in-socket design with a fixed RC located on the inferior endplate (BS-FI) and on the superior endplate (BS-FS), with a mobile RC at the inferior endplate (BS-MI), dual articulation with a mobile RC between the endplates (DA-M), and sliding articulation with various RCs (SA-V). The spinal motions in flexion and extension served as a displacement loading at the C3 vertebrae. Results. Total disc replacements reduced extension moment. The ball-in-socket designs required less flexion moment, whereas the flexion stiffness of the spines with DA-M and SA-V was similar to that of the healthy model. The contributions of the implanted level to the global motions increased in the total disc replacements, except in the SA-V and DA-M models (in flexion). Ball-in-socket designs produced severe stress distributions in facet cartilage, whereas DA-M and SA-V produced more severe stress distribution on the bone-implant interface. Conclusion. Cervical stability was extremely affected in extension and partially affected in flexion by total disc replacement. With the prostheses with mobile RC, cervical curvature was readjusted under a low follower load. The SA-V and BS-FS designs exhibited better performances in the entire segmental stiffness and in the stability of the operative level than the BS-MI and BS-FI designs in flexion. The 5 designs demonstrated varying advantages relative to the stress distribution in the facet cartilages and on the bone-implant interface. Level of Evidence: 5

8 June 2014 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
ZJZhiwei Jia
Zhiwei Jia
ZMZhongjun Mo
Zhongjun Mo
FDFan Ding
Fan Ding
QHQing He
Qing He
Yubo FanYubo Fan
Yubo Fan
DRDike Ruan
Dike Ruan

1 January 2017 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
SSShonglun Su
Shonglun Su
ZMZhongjun Mo
Zhongjun Mo
JGJunchao Guo
Junchao Guo
Yubo FanYubo Fan
Yubo Fan
Flat foot is one of the common deformities in the youth population, seriously affecting the weight supporting and daily exercising. However, there is lacking of quantitative data relative to material selection and shape design of the personalized orthopedic insole. This study was to evaluate the biomechanical effects of material hardness and support height of personalized orthopedic insole on foot tissues, by in vivo experiment and finite element modeling. The correction of arch height increased with material hardness and support height. The peak plantar pressure increased with the material hardness, and these values by wearing insoles of 40° were apparently higher than the bare feet condition. Harder insole material results in higher stress in the joint and ligament stress than softer material. In the calcaneocuboid joint, the stress increased with the arch height of insoles. The material hardness did not apparently affect the stress in the ankle joints, but the support heights of insole did. In general, insole material and support design are positively affecting the correction of orthopedic insole, but negatively resulting in unreasonable stress on the stress in the joint and ligaments. There should be an integration of improving correction and reducing stress in foot tissues.

24 October 2013 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
ZMZhongjun Mo
Zhongjun Mo
YZYan Bin Zhao
Yan Bin Zhao
LWLi Zhen Wang
Li Zhen Wang
YSYu Sun
Yu Sun
MZMing Zhang
Ming Zhang
Yubo FanYubo Fan
Yubo Fan