Elazer R. Edelman

Prof. Elazer R. Edelman

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2007 in JACC
Verified
Journal Article
Closed access
YCYiannis S. Chatzizisis
Yiannis S. Chatzizisis
ACAhmet Umit Coskun
Ahmet Umit Coskun
MJMichael Jonas
Michael Jonas
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
CFCharles L. Feldman
Charles L. Feldman
PSPeter H. Stone
Peter H. Stone

5 April 2011 in Circulation
Verified
Journal Article
Closed access
PDF file
KKKumaran Kolandaivelu
Kumaran Kolandaivelu
RSRajesh Swaminathan
Rajesh Swaminathan
WGWilliam J. Gibson
William J. Gibson
VKVijaya B Kolachalama
Vijaya B Kolachalama
KNKim-Lien Nguyen-Ehrenreich
Kim-Lien Nguyen-Ehrenreich
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
Background—: Stent thrombosis is a lethal complication of endovascular intervention. Concern has been raised about the inherent risk associated with specific stent designs and drug-eluting coatings, yet clinical and animal support is equivocal. Methods and Results—: We examined whether drug-eluting coatings are inherently thrombogenic and if the response to these materials was determined to a greater degree by stent design and deployment with custom-built stents. Drug/polymer coatings uniformly reduce rather than increase thrombogenicity relative to matched bare metal counterparts (0.65-fold; P =0.011). Thick-strutted (162 μm) stents were 1.5-fold more thrombogenic than otherwise identical thin-strutted (81 μm) devices in ex vivo flow loops ( P <0.001), commensurate with 1.6-fold greater thrombus coverage 3 days after implantation in porcine coronary arteries ( P =0.004). When bare metal stents were deployed in malapposed or overlapping configurations, thrombogenicity increased compared with apposed, length-matched controls (1.58-fold, P =0.001; and 2.32-fold, P <0.001). The thrombogenicity of polymer-coated stents with thin struts was lowest in all configurations and remained insensitive to incomplete deployment. Computational modeling–based predictions of stent-induced flow derangements correlated with spatial distribution of formed clots. Conclusions—: Contrary to popular perception, drug/polymer coatings do not inherently increase acute stent clotting; they reduce thrombosis. However, strut dimensions and positioning relative to the vessel wall are critical factors in modulating stent thrombogenicity. Optimal stent geometries and surfaces, as demonstrated with thin stent struts, help reduce the potential for thrombosis despite complex stent configurations and variability in deployment.

1 March 2018 in Cell Stem Cell
Verified
Journal Article
Closed access
HSH.-H. Greco Song
H.-H. Greco Song
RRRowza T. Rumma
Rowza T. Rumma
COC. Keith Ozaki
C. Keith Ozaki
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
CCChristopher S. Chen
Christopher S. Chen

31 July 2001 in Circulation
Verified
Journal Article
Closed access
PDF file
CHChao-Wei Hwang
Chao-Wei Hwang
DWDavid Wu
David Wu
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
Background The first compounds considered for stent-based delivery, such as heparin, were chosen on the basis of promising tissue culture and animal experiments, and yet they have failed to stop restenosis clinically. More recent compounds, such as paclitaxel, are of a different sort, being hydrophobic in nature, and their effects after local release seem far more profound. This dichotomy raises the question of whether drugs that have an effect when released from a stent do so because of differences in biology or differences in physicochemical properties and targeting. Methods and Results We applied continuum pharmacokinetics to examine the effects of transport forces and device geometry on the distribution of stent-delivered hydrophilic and hydrophobic drugs. We found that stent-based delivery invariably leads to large concentration gradients, with drug concentrations ranging from nil to several times the mean tissue concentration over a few micrometers. Concentration variations were a function of the Peclet number (Pe), the ratio of convective to diffusive forces. Although hydrophobic drugs exhibited greater variability than hydrophilic drugs, they achieved higher mean concentrations and remained closer to the intima. Inhomogeneous strut placement influenced hydrophilic drugs more negatively than hydrophobic drugs, dramatically affecting local concentrations without changing mean concentrations. Conclusions Because local concentrations and gradients are inextricably linked to biological effect, our results provide a potential explanation for the variable success of stent-based delivery. We conclude that mere proximity of delivery devices to tissues does not ensure adequate targeting, because physiological transport forces cause local concentrations to deviate significantly from mean concentrations.

26 February 2008 in Circulation
Verified
Journal Article
Closed access
PDF file
YCYiannis S. Chatzizisis
Yiannis S. Chatzizisis
MJMichael Jonas
Michael Jonas
ACAhmet U. Coskun
Ahmet U. Coskun
RBRoy Beigel
Roy Beigel
BSBenjamin V. Stone
Benjamin V. Stone
PSPeter H. Stone
Peter H. Stone
Background— Low endothelial shear stress (ESS) promotes the development of atherosclerosis; however, its role in the progression of atherosclerotic plaques and evolution to inflamed high-risk plaques has not been studied. Our hypothesis was that the lowest values of ESS are responsible for the development of high-risk coronary atherosclerotic plaques associated with excessive expansive remodeling. Methods and Results— Twenty-four swine, treated with streptozotocin to induce diabetes and fed a high-fat diet, were allocated into early (n=12) and late (n=12) atherosclerosis groups. Intima-media thickness was assessed by intravascular ultrasound in the coronary arteries at weeks 4 and 8 in the early group and weeks 23 and 30 in the late group. Plaques started to develop after week 8, leading to marked heterogeneity in plaque severity at week 30. ESS was calculated in plaque-free subsegments of interest (n=142) in the late group at week 23. Coronary arteries (n=31) of this group were harvested at week 30, and the subsegments of interest were identified and analyzed histopathologically. Low ESS was an independent predictor of the development of high-risk plaques, characterized by intense lipid accumulation, inflammation, thin fibrous cap, severe internal elastic lamina degradation, and excessive expansive remodeling. The severity of high-risk plaque characteristics at week 30 was significantly correlated with the magnitude of low ESS at week 23. Conclusions— The magnitude of low ESS determines the complexity and heterogeneity of atherosclerotic lesions and predicts the development of high-risk plaque.

9 July 2019 in Circulation
Verified
Journal Article
Closed access
PDF file
AKAditya S. Kalluri
Aditya S. Kalluri
SVShamsudheen K. Vellarikkal
Shamsudheen K. Vellarikkal
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
LNLan Nguyen
Lan Nguyen
ASAyshwarya Subramanian
Ayshwarya Subramanian
RGRajat M. Gupta
Rajat M. Gupta
Background: The cells that form the arterial wall contribute to multiple vascular diseases. The extent of cellular heterogeneity within these populations has not been fully characterized. Recent advances in single-cell RNA-sequencing make it possible to identify and characterize cellular subpopulations. Methods: We validate a method for generating a droplet-based single-cell atlas of gene expression in a normal blood vessel. Enzymatic dissociation of 4 whole mouse aortas was followed by single-cell sequencing of >10 000 cells. Results: Clustering analysis of gene expression from aortic cells identified 10 populations of cells representing each of the main arterial cell types: fibroblasts, vascular smooth muscle cells, endothelial cells (ECs), and immune cells, including monocytes, macrophages, and lymphocytes. The most significant cellular heterogeneity was seen in the 3 distinct EC populations. Gene set enrichment analysis of these EC subpopulations identified a lymphatic EC cluster and 2 other populations more specialized in lipoprotein handling, angiogenesis, and extracellular matrix production. These subpopulations persist and exhibit similar changes in gene expression in response to a Western diet. Immunofluorescence for Vcam1 and Cd36 demonstrates regional heterogeneity in EC populations throughout the aorta. Conclusions: We present a comprehensive single-cell atlas of all cells in the aorta. By integrating expression from >1900 genes per cell, we are better able to characterize cellular heterogeneity compared with conventional approaches. Gene expression signatures identify cell subpopulations with vascular disease–relevant functions.