This paper firstly provides an overview of major efforts made over the past several decades on developing the test apparatus for the study of erosion-corrosion of ferrous-based steels. The merits and the application range of the set-ups, i.e., rotating disc/cylinder electrode system, slurry jet impingement rig, and test flow loop, are introduced. Secondly, the advantages and limitations of both non-electrochemical and electrochemical methods used for the measurement of erosion-corrosion are presented. Thereafter, the interaction between erosion and corrosion using a cyclic erosion-corrosion method was introduced. The synergy between erosion and corrosion for the steels under the passive state were analyzed on the basis of the breakdown and restoration of the passive film. In addition, the difference between the obtained erosion-enhanced corrosion and the corrosion-enhanced erosion using different experimental methods for steels under active corrosion was discussed. Finally, the interaction between the localized corrosion and erosion was studied through the dynamic change of the local current distribution revealed by the wire beam electrode.
In this paper, a new kind of carbon steel (CS) and stainless steel (SS) galvanic sensor system was developed for the study of rebar corrosion in different pore solution conditions. Through the special design of the CS and SS electronic coupons, the electronic resistance (ER) method and zero resistance ammeter (ZRA) technique were used simultaneously for the measurement of both the galvanic current and the corrosion depth. The corrosion processes in different solution conditions were also studied by linear polarization resistance (LPR) and the measurements of polarization curves. The test result shows that the galvanic current noise can provide detailed information of the corrosion processes. When localized corrosion occurs, the corrosion rate measured by the ER method is lower than the real corrosion rate. However, the value measured by the LPR method is higher than the real corrosion rate. The galvanic current and the corrosion current measured by the LPR method shows linear correlation in chloride-containing saturated Ca(OH)2 solution. The relationship between the corrosion current differences measured by the CS electronic coupons and the galvanic current between the CS and SS electronic coupons can also be used to evaluate the localized corrosion in reinforced concrete.
17 May 2016 in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
In this paper, a ring form electronic resistance (ER) sensor system was developed for the study of under-deposit corrosion (UDC) caused by mineral deposit in pipeline conditions. The corrosion status of different locations along the pipeline circle direction and the galvanic current between the deposit-covered area and the bare steel area were monitored by the conjunction of the ER method and electrochemical noise technique. The performance of inhibitor ethylene diamine tetra methylene phosphonic acid sodium (EDTMPS) on UDC was studied by both the electrochemical method and the ring form ER sensor system. The measurement results demonstrated that the inhomogeneous distribution of the rust layer will cause heterogeneous corrosion patterns in the pipeline. Though EDTMPS showed an excellent inhibition effect for the corrosion of both deposit-covered steel and bare steel in electrochemical tests, it failed for the inhibition of UDC in the pipeline working conditions and serious localised corrosion beneath the sand particle was monitored by the sensor system.
2 April 2016 in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
In this work, the evaluation of under deposit corrosion (UDC) behaviour of X65 pipeline steel and its inhibition in oxygen corrosion conditions were studied. In the fundamental experimental study, a three-electrode electrochemical system was used to measure the corrosion rates and polarisation curves by linear polarisation resistance and potentiodynamic polarisation methods. The galvanic effect caused by the deposit was also studied by the zero resistance ammeter technique. An 8 in X65 pipeline internal corrosion monitoring system based on the ring pair electrical resistance sensor (RPERS) was established for further research of UDC. The underdeposit corrosion rate and its inhibitory effect in the pipeline were also monitored by RPERS. Electrochemical test results showed that the corrosion inhibitor amino trimethylenephosphonic acid (ATMP) would result an accelerate corrosion for UDC. A nearly 1.7 times increase was found on the galvanic current when ATMP was introduced into the solution. The inhibitor imidazoline had a good performance on UDC for both corrosion inhibiting and the reduction of the galvanic current. Through the monitoring results of RPERS, the UDC status in the pipeline and the effect of the inhibitors were studied. The monitoring results have a consistency with the fundamental experiment.