Alon Skaat

Dr. Alon Skaat


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Ophthalmology
Verified
Journal Article
Closed access
ASAlon Skaat
Alon Skaat
CMCarlos Gustavo De Moraes
Carlos Gustavo De Moraes
CBChristopher Bowd
Christopher Bowd
PSPamela A. Sample
Pamela A. Sample
CGChristopher A. Girkin
Christopher A. Girkin
JLJeffrey M. Liebmann
Jeffrey M. Liebmann

1 March 2021 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
MGMordechai Goldenfeld
Mordechai Goldenfeld
MBMichael Belkin
Michael Belkin
MDMasha Dobkin-Bekman
Masha Dobkin-Bekman
ZSZachary Sacks
Zachary Sacks
SMSharon Blum Meirovitch
Sharon Blum Meirovitch
ASAlon Skaat
Alon Skaat
Purpose: Direct selective laser trabeculoplasty (DSLT) is a rapid, noncontact automated procedure performed directly through the limbus without gonioscopy. In this first nonrandomized clinical trial we assessed its safety and ability to reduce intraocular pressure (IOP). Methods: Fifteen patients (15 eyes: 10 with open-angle glaucoma [OAG], 4 with ocular hypertension, and 1 with pseudoexfoliation glaucoma), naive or after medication washout, with an IOP ≥22 mm Hg, underwent DSLT by irradiation with 100 or 120 sequential noncontact 532-nm, Q-switched laser shots (0.8−1.4 mJ) automatically applied during 1.5 or 2.3 seconds on the limbus, guided by image analysis and eye tracking. Results were assessed at 1 and 3 hours, 1 day, 1 week, and 1, 3, and 6 months. Results: The mean ± standard deviation baseline IOP (mm Hg) in all eyes was 26.7 ± 2.3. At 1, 3, and 6 months, this value was significantly reduced to 21.7 ± 4.2 (by 18.1%), to 20.8 ± 2.5 (by 21.4%), and to 21.5 ± 4.1 (by 18.8%), respectively. In six patients treated with 1.4 mJ/shot, the mean IOP at 6 months decreased from 26.7 ± 3.2 to 19.3 ± 2.0 (27.1%, P = 0.03). There was a significant reduction in hypotensive medications (from 1.6 ± 1.0 to 0.4 ± 0.7, P = 0.03). No serious adverse events occurred. Conclusions: Automated DSLT appears to be an effective and safe noncontact, rapid modality for reducing IOP in patients with OAG. Higher energy usage led to better results. Translational Relevance: Studying laser transmission through sclera enabled laser irradiation of the trabeculum without gonioscopy.

24 March 2020 in Journal of Glaucoma
Verified
Journal Article
Closed access
ALAri Leshno
Ari Leshno
YRYair Md Rubinstein
Yair Md Rubinstein
RSReut Singer
Reut Singer
ISIfat Sher
Ifat Sher
YRYgal Rotenstreich
Ygal Rotenstreich
ASAlon Skaat
Alon Skaat
Precis: Ultrasound Cyclo Plasty (UCP) treatment using high-intensity focused ultrasound (HIFU) is an effective and safe therapy to reduce intraocular pressure (IOP) in moderate glaucoma patients as was measured during a 2-year follow-up period. Purpose: The purpose of this study was to evaluate the long-term safety and efficacy of the UCP procedure using HIFU in moderate glaucoma patients. Patients and Methods: A prospective interventional noncomparative study was carried out. Fifteen patients (15 eyes) with moderate open-angle glaucoma were enrolled. All eyes were treated with UCP-HIFU. A thorough ophthalmic examination and IOP measurements were performed before the UCP-HIFU procedure and at 1 day, 1 week, 4 weeks, 3 months, 6 months, 1 year, and 2 years after the procedure. The primary outcome was defined as a surgical success (IOP reduction of 20% or ≥5 mm Hg) at the last follow-up visit. The secondary outcomes were the mean IOP at each follow-up visit, number of medications used, complications profile, and reinterventions. Results: The mean preoperative IOP at baseline was 26.8±5.0 mm Hg. All patients had a positive response and a lower IOP after treatment, with a relatively stable 31% reduction in IOP during the follow-up period. A significant reduction in IOP was observed at all postprocedure examination points (P<0.01), with a mean 17.6±4.4 mm Hg at 2 years after the procedure (P=0.005). Surgical success was achieved in 87% of the patients at their last follow-up visit. There was a nonsignificant decrease in the mean number of glaucoma medications from 2.5±0.8 to 2.0±1.0 at 2 years (P=0.48). No major intraoperative or postoperative complications were noted. Conclusion: UCP-HIFU treatment is an effective, safe, and well-tolerated method to reduce IOP in patients with moderate glaucoma.

9 June 2021 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
ALAri Leshno
Ari Leshno
OSOri Stern
Ori Stern
YBYaniv Barkana
Yaniv Barkana
NKNoa Kapelushnik
Noa Kapelushnik
RSReut Singer
Reut Singer
ASAlon Skaat
Alon Skaat
Accumulating evidence suggests that neuroinflammation and immune response are part of the sequence of pathological events leading to optic nerve damage in glaucoma. Changes in tissue temperature due to inflammation can be measured by thermographic imaging. We investigated the ocular surface temperature (OST) profile of glaucomatous eyes to better understand the pathophysiology of these conditions. Subjects diagnosed with glaucoma (primary open angle glaucoma [POAG] or pseudo exfoliation glaucoma [PXFG]) treated at the Sam Rothberg Glaucoma Center (11/2019–11/2020.) were recruited. Healthy subjects with no ocular disease served as controls. The Therm-App thermal imaging camera was used for OST acquisition. Room and body temperatures were recorded, and the mean temperatures of the medial cantus, lateral cantus, and cornea were calculated with image processing software. Thermographic images were obtained from 52 subjects (52 eyes: 25 POAG and 27 PXFG) and 66 controls (66 eyes). Eyes with glaucoma had a significantly higher OST compared to controls (mean 0.9 ± 0.3°C, p < 0.005). The difference between the two groups remained significant after adjustment for age, sex, intraocular pressure (IOP) and room and body temperatures. Lens status and topical IOP-lowering medication did not significantly affect OST. A subgroup analysis revealed that the OST was higher among eyes with POAG compared to eyes with PXFG, but not significantly. Differences in the OST between glaucomatous and normal eyes strengthens current thinking that inflammation affects the pathophysiology of glaucoma. Longitudinal studies are warranted to establish the prognostic value of thermographic evaluations in these patients.

27 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MFMichele Figus
Michele Figus
CPChiara Posarelli
Chiara Posarelli
MNmarco nardi
marco nardi
ISIngeborg Stalmans
Ingeborg Stalmans
EVEvelien Vandewalle
Evelien Vandewalle
LPLuis Abegão Pinto
Luis Abegão Pinto
Background: The purpose of this prospective study was to evaluate the efficacy and safety of the Ultrasound Cyclo Plasty (UCP) procedure using high-intensity focused ultrasound in surgery-naïve open-angle glaucoma patients. Methods: prospective, non-randomized, single-arm, multicenter clinical trial. Sixty-six eyes with primary open-angle glaucoma, intraocular pressure (IOP) ≥21 mmHg and with no history of filtering surgery were enrolled. Patients were treated by UCP with a therapy probe comprising six piezoelectric transducers, consecutively activated for 8 s each. Complete ophthalmic examination was performed before the procedure, 1 day after the procedure, and 1, 3, 6, 12, 18 and 24 months after the procedure. Primary outcomes were complete success (defined as IOP lowering from baseline ≥20% without additional glaucoma medications) and vision-threatening complications. Secondary outcomes were the presence of complications and the reduction of the number of medications used. Results: IOP was significantly reduced after one procedure (p < 0.05), from a mean pre-operative value of 24.3 ± 2.9 mmHg (n = 2.3 hypotensive medications) to a mean value of 15.9 ± 3.6 mmHg (n = 2.2 hypotensive medications) at 2 years (mean IOP lowering of 33%). Surgical success was achieved in 74% of eyes. Notwithstanding side effects such as transient anterior chamber inflammation, refractive error changes, transient hypotony and macular edema, no major intra or post-operative complications such as phthisis, induced cataract, neovascularization or significant vision loss were observed. Conclusions: Ultrasound Cyclo Plasty is a valuable, effective and well-tolerated procedure to lower IOP in patients with open-angle glaucoma without previous filtering surgery.

10 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
NKNoa kapelushnik
Noa kapelushnik
SBShahar Benyosef
Shahar Benyosef
ASAlon Skaat
Alon Skaat
AAAmir Abdelkader
Amir Abdelkader
DLDaphna Landau
Daphna Landau
ALAri Leshno
Ari Leshno
Due to the COVID-19 pandemic, the center for disease control and prevention (CDC) recommends face-mask wearing for all people above the age of two years. The wearing of face masks creates a unique airflow towards the ocular surface which may influence the normal physiological conditions of the ocular and periocular surface. Healthy subjects with no ocular history were enrolled in this cross-sectional study. The Therm-App thermal imaging camera was used for ocular surface temperature (OST) measurements during inspirium and expirium. Five regions of interest (ROIs) were used to measure OST: medial conjunctive, cornea, lateral conjunctive, upper eyelid and entire orbital area. Additional measurements in the same locations were made with the upper margin of the mask taped with micropore surgical tape. Thirty-one patients were included in this study. OST during expirium was significantly higher compared to the temperature during inspirium in all locations measured (p < 0.001, paired samples t-test). The temperature of the upper eyelid was higher by more than 0.5 °C during expirium. Taping the mask’s upper edges to the skin resulted in non-significant temperature changes in inspirium vs. expirium. In conclusion, wearing a face mask creates air flow towards the periocular and ocular surface, which changes the OST mostly on the eyelids.
1