Dhrubo Jyoti

Dr. Dhrubo Jyoti


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DJDhrubo Jyoti
Dhrubo Jyoti
SGScott W. Gordon-Wylie
Scott W. Gordon-Wylie
DRDaniel Reeves
Daniel Reeves
KPKeith D. Paulsen
Keith D. Paulsen
JWJohn B Weaver
John B Weaver
Magnetic particle spectroscopy (MPS) in the Brownian relaxation regime, also termed magnetic spectroscopy of Brownian motion (MSB), can detect and quantitate very low, sub-nanomolar concentrations of molecular biomarkers. MPS/MSB uses the harmonics of the magnetization induced by a small, low-frequency oscillating magnetic field to provide quantitative information about the magnetic nanoparticles’ (mNPs’) microenvironment. A key application uses antibody-coated mNPs to produce biomarker-mediated aggregation that can be detected using MPS/MSB. However, relaxation changes can also be caused by viscosity changes. To address this challenge, we propose a metric that can distinguish between aggregation and viscosity. Viscosity changes scale the MPS/MSB harmonic ratios with a constant multiplier across all applied field frequencies. The change in viscosity is exactly equal to the multiplier with generality, avoiding the need to understand the signal explicitly. This simple scaling relationship is violated when particles aggregate. Instead, a separate multiplier must be used for each frequency. The standard deviation of the multipliers over frequency defines a metric isolating viscosity (zero standard deviation) from aggregation (non-zero standard deviation). It increases monotonically with biomarker concentration. We modeled aggregation and simulated the MPS/MSB signal changes resulting from aggregation and viscosity changes. MPS/MSB signal changes were also measured experimentally using 100 nm iron-oxide mNPs in solutions with different viscosities (modulated by glycerol concentration) and with different levels of aggregation (modulated by concanavalin A linker concentrations). Experimental and simulation results confirmed that viscosity changes produced small changes in the standard deviation and aggregation produced larger values of standard deviation. This work overcomes a key barrier to using MPS/MSB to detect biomarkers in vivo with variable tissue viscosity.

1 March 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DJDhrubo Jyoti
Dhrubo Jyoti
MMMatthew McGarry
Matthew McGarry
DCDiego A. Caban-Rivera
Diego A. Caban-Rivera
EHElijah Van Houten
Elijah Van Houten
CJCurtis L Johnson
Curtis L Johnson
KPKeith Paulsen
Keith Paulsen

5 April 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
DJDhrubo Jyoti
Dhrubo Jyoti
MMMatthew McGarry
Matthew McGarry
EHElijah Van Houten
Elijah Van Houten
DSDamian Radoslaw Sowinski
Damian Radoslaw Sowinski
PBPhilip V Bayly
Philip V Bayly
KPKeith Paulsen
Keith Paulsen
Easily computable quality metrics for measured medical data at point-of-care are important for imaging technologies involving offline reconstruction. Accordingly, we developed a new data quality metric for in vivo transversely-isotropic (TI) magnetic resonance elastography (MRE) based on a generalization of the widely accepted octahedral shear-strain calculation. The metric uses MRE displacement data and an estimate of the TI property field to yield a ‘stability map’ which predicts regions of low versus high accuracy in the resulting material property reconstructions. We can also calculate an average TI parameter stability (TIPS) score over all voxels in a region of interest for a given measurement to indicate how reliable the recovered mechanical property estimate for the region is expected to be. The calculation is rapid and places little demand on computing resources compared to the computationally intensive material property reconstruction from non-linear inversion (TI-NLI) of displacement fields, making it ideal for point-of-care evaluation of data quality. We test the predictions of the stability map for both simulated phantoms and in vivo human brain data. We used a range of different displacement datasets from vibrations applied in the anterior-posterior (AP), left-right (LR) and combined AP + LR directions. The TIPS and variability maps (noise sensitivity or variation from the mean of repeated MRE scans) were consistently anti-correlated. Notably, Spearman correlation coefficients ∣R∣>0.6 were found between variability and TIPS score for individual white matter tracts with in vivo data. These observations demonstrate the reliability and promise of this data quality metric to screen data rapidly in realistic clinical MRE applications.

23 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
DJDhrubo Jyoti
Dhrubo Jyoti
DRDaniel Reeves
Daniel Reeves
SGScott Gordon-Wylie
Scott Gordon-Wylie
CEClifford Joseph Eskey
Clifford Joseph Eskey
JWJohn B Weaver
John B Weaver
(1) Background: Mechanical thrombectomy (MT) successfully treats ischemic strokes by extracting the thrombus, or clot, using a stent retriever to pull it through the blood vessel. However, clot slippage and/or fragmentation can occur. Real-time feedback to a clinician about attachment between the stent and clot could enable more complete removal. We propose a system whereby antibody-targeted magnetic nanoparticles (NPs) are injected via a microcatheter to coat the clot, oscillating magnetic fields excite the particles, and a small coil attached to the catheter picks up a signal that determines the proximity of the clot to the stent. (2) Methods: We used existing simulation code to model the signal from NPs distributed on a hemispherical clot with three orthogonally applied magnetic fields. An in vitro apparatus was built that applied fields and read out signals from a 1.5 mm pickup coil at a variable distance and orientation angle from a sample of 100 nm iron oxide core/shell NPs. (3) Results: Our simulations suggest that the sum of the voltages induced in the pickup coil from three orthogonal applied fields could localize a clot to within 180 µm, regardless of the exact orientation of the pickup coil, with further precision added via rotation-correction formulae. Our experimental system validated simulations; we estimated an in vitro distance recovery precision of 41 µm with a pickup coil 1 mm from the clot. (4) Conclusions: Magnetic NP sensing could be a safe and real-time method to estimate whether a clot is attached to the stent retriever during MT.

30 October 2014 in arXiv
Verified
Preprint
Open access
PDF file
SAStephon Alexander
Stephon Alexander
DJDhrubo Jyoti
Dhrubo Jyoti
AKArthur Kosowsky
Arthur Kosowsky
AMAntonino Marciano
Antonino Marciano
We analyze the existence and stability of dynamical attractor solutions for cosmological inflation driven by the coupling between fermions and a gauge field. Assuming a spatially homogeneous and isotropic gauge field and fermion current, the interacting fermion equation of motion reduces to that of a free fermion up to a phase shift. Consistency of the model is ensured via the Stuckelberg mechanism. We prove the existence of exactly one stable solution, and demonstrate the stability numerically. Inflation arises without fine tuning, and does not require postulating any effective potential or non-standard coupling.