Miguel Louro

Mr. Miguel Louro

E-REDES, Lisbon, Lisboa, Portugal

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2022 in IEEE Access
Verified
Journal Article
Open access
JAJosé Andrade
José Andrade
CRC. Rocha
C. Rocha
RSRicardo Silva
Ricardo Silva
JVJ. P. Viana
J. P. Viana
Ricardo BessaRicardo Bessa
Ricardo Bessa
ARA. F. Ribeiro
A. F. Ribeiro
Network human operators’ decision-making during grid outages requires significant attention and the ability to perceive real-time feedback from multiple information sources to minimize the number of control actions required to restore service, while maintaining the system and people safety. Data-driven event and alarm management have the potential to reduce human operator cognitive burden. However, the high complexity of events, the data semantics, and the large variety of equipment and technologies are key barriers for the application of Artificial Intelligence (AI) to raw SCADA data. In this context, this paper proposes a methodology to convert a large volume of alarm events into data mining terminology, creating the conditions for the application of modern AI techniques to alarm data. Moreover, this work also proposes two novel data-driven applications based on SCADA data: (i) identification of anomalous behaviors regarding the performance of the protection relays of primary substations, during circuit breaker tripping alarms in High Voltage (HV) and Medium Voltage (MV) lines; (ii) unsupervised learning to cluster similar events in HV line panels, classify new event logs based on the obtained clusters and membership grade with a control parameter that helps to identify rare events. Important aspects associated with data handling and pre-processing are also covered. The results for real data from a Distribution System Operator (DSO) showed: (i) that the proposed method can detect unexpected relay pickup events, e.g., one substation with nearly 41% of the circuit breaker alarms had an ‘atypical’ event in their context (revealed an overlooked problem on the electrification of a protection relay); (ii) capability to automatically detect and group issues into specific clusters, e.g., SF6 low-pressure alarms and blocks with abnormal profiles caused by event time-delay problems.

9 August 2010 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JSJosé L. Pinto de Sa
José L. Pinto de Sa
MLMiguel Louro
Miguel Louro
The minimum phase-to-ground fault current required to be sensed by protection systems in medium-voltage (MV) networks can be as low as 0.7 A in a few countries, leading to a lot of undesired relay trips and poor service quality to costumers. However, these settings raise the protection threshold above the minimum fault current that concerns network operators regarding human safety, although they cannot be practiced when grounding is distributed. The purpose of this paper is to present a risk assessment foundation to determine the required protection sensitivity to ensure human safety in MV distribution networks. The proposed approach is based on a biophysical model included in IEC standards, the consideration of current paths models for typical faults and Monte Carlo methods to deal with nonlinearity, and the many involved random variables. Downed conductors and line-to-concrete pole faults are investigated and sensitivity analysis performed to highlight some important determinants of the results.

23 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
TATiago Abreu
Tiago Abreu
TSTiago Soares
Tiago Soares
LCLeonel Magalhães Carvalho
Leonel Magalhães Carvalho
Hugo MoraisHugo Morais
Hugo Morais
TSTiago Simão
Tiago Simão
MLMiguel Louro
Miguel Louro
Challenges in the coordination between the transmission system operator (TSO) and the distribution system operator (DSO) have risen continuously with the integration of distributed energy resources (DER). These technologies have the possibility to provide reactive power support for system operators. Considering the Portuguese reactive power policy as an example of the regulatory framework, this paper proposes a methodology for proactive reactive power management of the DSO using the renewable energy sources (RES) considering forecast uncertainty available in the distribution system. The proposed method applies a stochastic sequential alternative current (AC)-optimal power flow (SOPF) that returns trustworthy solutions for the DSO and optimizes the use of reactive power between the DSO and DER. The method is validated using a 37-bus distribution network considering real data. Results proved that the method improves the reactive power management by taking advantage of the full capabilities of the DER and by reducing the injection of reactive power by the TSO in the distribution network and, therefore, reducing losses.

29 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
MLMiguel Louro
Miguel Louro
LFLuís Ferreira
Luís Ferreira
Electrical utilities performance is measured by various indicators, of which the most important are very dependent on the interruption time after a failure in the network has occurred, such as SAIDI. Therefore, they are constantly looking for new techniques to decrease the fault location and repair times. A possibility to innovate in this field is to estimate the failed network component when a fault occurs. This paper presents the conclusion of an analysis carried out by the authors with the aim to estimate failure types of underground MV networks based on observable indirect variables. The variables needed to carry out the analysis must be available shortly after the failure occurrence, which is facilitated by a smart-grid infrastructure, to allow for a quick estimation. This paper uses the groundwork already carried out by the authors on ambient variables, historical variables, and disturbance recordings to design an estimator to predict between four MV cable network failure types. The paper presents relevant analyses on the design and performance of various machine learning classification algorithms for estimation of the types of MV cable network failures using real-world data. Optimization of performance was carried out, resulting in an estimator with an overall 68% accuracy rate. Accuracy rates of 94% for cable failure, 63% for excavations, and 79% secondary busbar failures were achieved; as for cable joints, the accuracy was poor due to the difficulty to identify a feature that can be used to separate this failure type from cable failures. Future work to improve that accuracy is discussed.

24 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
MLMiguel Louro
Miguel Louro
LFLuís Ferreira
Luís Ferreira
The authors seek to investigate the characteristics of outage-causing faults that can be observed in a short time frame after their occurrence: waveform of the voltages and currents. The aim is to identify which characteristics can be used to estimate the failure type immediately after its occurrence. This paper lays the groundwork to determine which features display a stronger relation to four failure types with the aim of using this information in a later work, not presented in this paper, aimed at designing a reliable failure type estimator from readily available data. This paper focuses on the most common failures of the underground cable MV networks in Portugal: cable insulation; cable joint; secondary substation busbar; and excavation-motivated failures. A set of 206 waveform records of real underground MV network failures was available for analysis. After investigating the waveforms, the authors identified seven waveform characteristics which can be used for failure type estimation. Fault type characteristics can be used to distinguish secondary substation failures from the remaining failure types. Fault evolution does not yield relevant information. Fault self-extinction phenomenon was not observed in excavation-caused failures. There are differences for self-extinction characteristics between secondary substation busbar failures and the cable insulation and joint failures. Fault inception instant and arc voltage are two characteristics which are shown to have a promising merit to the identification process of failure types. Finally, fault intra-cycle repetitive extinction results have been found to be very similar for cable insulation failures and joint failures, but otherwise different regarding the remaining failure types.

13 December 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MLMiguel Louro
Miguel Louro
LFLuís Ferreira
Luís Ferreira
Electrical utilities are continuously searching for new ways to cut costs and effectively increase the quality of service being supplied to their clients, which is closely related to the number of failures and the time it takes to locate and repair them. A helpful input for this continuing effort would be to have an estimate of the type of failure when it occurs. The analysis presented in this paper is part of an effort being carried out to estimate failure types based on an analysis of observable indirect variables. These indirect variables must be readily available after the failure detection, through a Smart Grid infrastructure, to enable a future application to carry out the estimation. This paper lays the groundwork on ambient and historical variables that display a relationship with various types of MV cable network failures. The paper presents relevant data and analyses the relationship between the various failure types and indirect variables, such as date and time, loading, historical data, daily rainfall, accumulated rainfall, dew point and ambient temperature. Relationships between indirect variables and failure types are established to help identifying the most relevant variables for the design of the estimator.