In the paper, experimental analyses of the free convection heating transfer in a flat wavy-fin heat exchanger with the dimensions of 500 × 500 mm were investigated. The experimental reserch mainly included determining the average heat flux and heat-transfer coefficient for two selected types of finned heat exchangers. First, tests were conducted for exchangers without considering the so-called ’chimney’ effect; these tests will be treated as reference studies. Then, experiments for specially designed ’chimneys’ over the exchanger with heights of 350, 850, and 1350 mm, respectively, were carried out again. The analyses were performed for an average temperature difference between the heat-exchange surface and the environment in the range of 18 to 55 K. The experimental results demonstrated that, compared to the exchanger without a chimney, the addition of a chimney significantly affects the improvement in the thermal performance of the heat exchanger under natural convection conditions. Regarding the variant without a chimney, when a chimney is used with the highest height of 1350 mm and a maximum temperature difference of 55 K, the average heat flux increases by approximately 450% and the average heat-transfer coefficient is approximately 10 times higher. The heat exchanger characterised by lower airflow resistance showed higher values of average heat flux of 5 to 45% in the Rayleigh number range of 25 to 180. Studies have indicated that in some cases, a simple modification of the geometry of the heat exchanger leads to significant improvements in thermal performance and, in extreme cases, to the elimination of supporting equipment such as fans.

1 July 2025 in Energy Conversion and Management
Verified
Journal Article
Open access
DPDemis Pandelidis
Demis Pandelidis
MMMikołaj Matuszczak
Mikołaj Matuszczak
KDKrzysztof Dąbrowski
Krzysztof Dąbrowski
MMMichał Mirosław
Michał Mirosław
WWWilliam Worek
William Worek

28 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DPDemis Pandelidis
Demis Pandelidis
MMMikołaj Matuszczak
Mikołaj Matuszczak
PKPaweł Krowicki
Paweł Krowicki
BPBartosz Poskart
Bartosz Poskart
GIGrzegorz Iskierka
Grzegorz Iskierka
Sabri CetinSabri Cetin
Sabri Cetin
In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.