Yinsu Zhu

Dr. Yinsu Zhu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2023 in European Radiology
Verified
Journal Article
Closed access
PDF file
CFChangjing Feng
Changjing Feng
RCRui Chen
Rui Chen
SDSiting Dong
Siting Dong
WDWei Deng
Wei Deng
SLShushen Lin
Shushen Lin
YZYinsu Zhu
Yinsu Zhu

20 March 2021 in Rheumatology
Verified
Journal Article
Closed access
PDF file
CFChangjing Feng
Changjing Feng
WLWangyan Liu
Wangyan Liu
XSXiaoxuan Sun
Xiaoxuan Sun
QWQiang Wang
Qiang Wang
XZXiaomei Zhu
Xiaomei Zhu
YZYinsu Zhu
Yinsu Zhu
Myocardial involvement is frequently observed in PM and DM but typically remains subclinical. This study aimed to investigate characteristics of myocardial involvement and compare differences between patients with PM and DM by cardiac MR (CMR) imaging. From March 2017 to December 2019, a total of 17 PM and 27 DM patients were enrolled in this retrospective study. In all patients, clinical assessment and CMR examination were performed. CMR parameters, including left ventricular (LV) morphologic and functional parameters, and CMR tissue characterization imaging parameters, such as native T1, T2, extracellular volume (ECV) and late gadolinium enhancement, were analysed. In patients in both PM and DM groups, elevated global native T1 and ECV values were observed. Global ECV values were higher in the PM group when compared with the DM group (33.24 ± 2.97% vs 30.36 ± 4.20%; P = 0.039). Furthermore, patients in the PM and DM groups showed a different positive segment distribution of late gadolinium enhancement, native T1 and ECV, whereas the number of positive segments in PM patients was greater compared with that in DM patients. No significant differences in LV morphological and functional parameters were observed between patients in PM and DM groups, and most were in normal range. CMR tissue characterization imaging could detect early myocardial involvement in PM and DM patients without overt LV dysfunction. Furthermore, characteristics of myocardial involvement were different between PM and DM patients with more serious myocardial involvement seen in PM patients.

1 January 2024 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
XXXiaodong Xie
Xiaodong Xie
HYHongwei Yan
Hongwei Yan
KLKaifang Liu
Kaifang Liu
WGWeizheng Guan
Weizheng Guan
KLKai Luo
Kai Luo
WSWenrong Shen
Wenrong Shen
Background: The accurate assessment of lymph node metastasis (LNM) is crucial for the staging, treatment, and prognosis of lung cancer. In this study, we explored the potential value of dual-layer spectral detector computed tomography (SDCT) quantitative parameters in the prediction of LNM in non-small cell lung cancer (NSCLC). Methods: In total, 91 patients presenting with solid solitary pulmonary nodules (8 mm < diameter ≤30 mm) with pathologically confirmed NSCLC (57 without LNM, and 34 with LNM) were enrolled in the study. The patients’ basic clinical data and the SDCT morphological features were analyzed using the chi-square test or Fisher’s exact test. The Mann-Whitney U-test and independent sample t-test were used to analyze the differences in multiple SDCT quantitative parameters between the non-LNM and LNM groups. The diagnostic efficacy of the corresponding parameters in predicting LNM in NSCLC was evaluated by plotting the receiver operating characteristic (ROC) curves. A multivariate logistic regression analysis was conducted to determine the independent predictive factors of LNM in NSCLC. Interobserver agreement was assessed using intraclass correlation coefficients (ICCs) and Bland-Altman plots. Results: There were no significant differences between the non-LNM and LNM groups in terms of age, sex, and smoking history. Lesion size and vascular convergence sign differed significantly between the two groups (P<0.05), but there were no significant differences in the six tumor markers. The SDCT quantitative parameters [SAR40keV, SAR70keV, Δ40keV, Δ70keV, CER40keV, CER70keV, NEF40keV, NEF70keV, λ, normalized iodine concentration (NIC) and NZeff] were significantly higher in the non-LNM group than the LNM group (P<0.05). The ROC analysis showed that CER40keV, NIC, and CER70keV had higher diagnostic efficacy than other quantitative parameters in predicting LNM [areas under the curve (AUCs) =0.794, 0.791, and 0.783, respectively]. The multivariate logistic regression analysis showed that size, λ, and NIC were independent predictive factors of LNM. The combination of size, λ, and NIC had the highest diagnostic efficacy (AUC =0.892). The interobserver repeatability of the SDCT quantitative and derived quantitative parameters in the study was good (ICC: 0.801–0.935). Conclusions: The SDCT quantitative parameters combined with the clinical data have potential value in predicting LNM in NSCLC. The size + λ + NIC combined parameter model could further improve the prediction efficacy of LNM.

3 May 2024 in Journal of Thoracic Imaging
Verified
Journal Article
Closed access
RCRui Chen
Rui Chen
XLXiaohu MD Li
Xiaohu MD Li
HJHan Jia
Han Jia
CFChangjing Feng
Changjing Feng
SDSiting Dong
Siting Dong
YZYinsu Zhu
Yinsu Zhu
Purpose: The relationship between plaque progression and pericoronary adipose tissue (PCAT) radiomics has not been comprehensively evaluated. We aim to predict plaque progression with PCAT radiomics features and evaluate their incremental value over quantitative plaque characteristics. Patients and Methods: Between January 2009 and December 2020, 500 patients with suspected or known coronary artery disease who underwent serial coronary computed tomography angiography (CCTA) ≥2 years apart were retrospectively analyzed and randomly stratified into a training and testing data set with a ratio of 7:3. Plaque progression was defined with annual change in plaque burden exceeding the median value in the entire cohort. Quantitative plaque characteristics and PCAT radiomics features were extracted from baseline CCTA. Then we built 3 models including quantitative plaque characteristics (model 1), PCAT radiomics features (model 2), and the combined model (model 3) to compare the prediction performance evaluated by area under the curve. Results: The quantitative plaque characteristics of the training set showed the values of noncalcified plaque volume (NCPV), fibrous plaque volume, lesion length, and PCAT attenuation were larger in the plaque progression group than in the nonprogression group (P < 0.05 for all). In multivariable logistic analysis, NCPV and PCAT attenuation were independent predictors of coronary plaque progression. PCAT radiomics exhibited significantly superior prediction over quantitative plaque characteristics both in the training (area under the curve: 0.814 vs 0.615, P < 0.001) and testing (0.736 vs 0.594, P = 0.007) data sets. Conclusions: NCPV and PCAT attenuation were independent predictors of coronary plaque progression. PCAT radiomics derived from baseline CCTA achieved significantly better prediction than quantitative plaque characteristics.

22 February 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Guanyu YangGuanyu Yang
Guanyu Yang
YHYuting He
Yuting He
YLYang Lv
Yang Lv
YCYang Chen
Yang Chen
JCJean-Louis Coatrieux
Jean-Louis Coatrieux
YZYinsu Zhu
Yinsu Zhu
Pulmonary arterial hypertension (PAH) prognosis prediction on 3D non-contrast CT images is one of the most important tasks for PAH treatment. It will help clinicians stratify patients into different groups for early diagnosis and timely intervention via automatically extracting the potential biomarkers of PAH to predict mortality. However, it is still a task of great challenges due to the large volume and low-contrast regions of interest in 3D chest CT images. In this paper, we propose the first multi-task learning-based PAH prognosis prediction framework, P$^{2}$-Net , which effectively optimizes the model and powerfully represents task-dependent features via our Memory Drift (MD) and Prior Prompt Learning (PPL) strategies. 1) Our MD maintains a large memory bank to provide a dense sampling of the deep biomarkers' distribution. Therefore, although the batch size is very small caused by our large volume, a reliable (negative log partial) likelihood loss is still able to be calculated on a representative probability distribution for robust optimization. 2) Our PPL simultaneously learns an additional manual biomarkers prediction task to embed clinical prior knowledge into our deep prognosis prediction task in hidden and explicit ways. Therefore, it will prompt the prediction of deep biomarkers and improve the perception of task-dependent features in our low-contrast regions. Our P $^{2}$ -Net achieves a high prognostic correlation of the prediction and great generalization with the highest 70.19% C-index and 2.14 HR. Extensive experiments with promising results on our PAH prognosis prediction reveal powerful prognosis performance and great clinical significance in PAH treatment. All of our code will be made publicly available online Opened source: https://github.com/YutingHe-list/P2-Net .

27 October 2022
Verified
Book Chapter
Closed access
PDF file
XYXiaohan Yuan
Xiaohan Yuan
YZYinsu Zhu
Yinsu Zhu