Yong Liu

Dr. Yong Liu

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Chinese Physics C
Verified
Journal Article
Closed access
PDF file
CZChuan Zhao
Chuan Zhao
SSSheng-Sen Sun
Sheng-Sen Sun
CLCheng Li
Cheng Li
XZXiao-Jie Zhang
Xiao-Jie Zhang
KHKang-Lin He
Kang-Lin He
JZJia-Xu Zuo
Jia-Xu Zuo
The time calibration for end cap TOF system of BES is studied in this paper.It has achieved about 110 ps time resolution for muons in dimu events.The pulse height correction using electronic scan curve and the predicted time calculated using Kalman filter method are introduced.This paper also describes the study of using electrons and muons as calibration samples.

1 November 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
JJJiechen Jiang
Jiechen Jiang
SZShensen Zhao
Shensen Zhao
YNYazhou Niu
Yazhou Niu
YSYukun Shi
Yukun Shi
YLYong Liu
Yong Liu
BYBoxiang Yu
Boxiang Yu

1 May 2022 in Journal of Instrumentation
Verified
Journal Article
Open access
YDY. Duan
Y. Duan
JJJ. Jiang
J. Jiang
JLJ. Li
J. Li
LLL. Li
L. Li
SLS. Li
S. Li
YZY. Zhang
Y. Zhang
Hadron calorimeter (HCAL) is an essential sub-detector of the baseline detector system for Circular Electron Positron Collider (CEPC). We plan to build an Analog Hadron CALorimeter (AHCAL) prototype based on the Particle Flow Algorithm (PFA). The AHCAL of CEPC uses steel as the absorber and scintillator tiles read out by Silicon Photo-Multipliers (SiPMs) as the sensitive medium. The energy linearity and resolution of the calorimeter depend on the light yield uniformity of the sensitive medium. It is essential to qualify the entire detector production in order to select scintillator tiles with the uniformity of light yield within 10%. An automated batch test platform has been designed with 144 channels and an automated 3D servo motor. The paper summarizes the tests performed on more than 15000 scintillator tiles, and the SiPMs work at 59 V (overvoltage: 5 V). The measured light yield, corrected for the set-up response non-uniformity, is around 12.9 p.e. About 91.6% of scintillators (14219 pieces) are qualified within 10% of the light yield window.

1 August 2023 in Journal of Instrumentation
Verified
Journal Article
Open access
BAB. Acar
B. Acar
GAG. Adamov
G. Adamov
CAC. Adloff
C. Adloff
SAS. Afanasiev
S. Afanasiev
NAN. Akchurin
N. Akchurin
XZX. Zhao
X. Zhao
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

15 September 2022 in Instruments
Verified
Journal Article
Open access
PDF file
BQBaohua Qi
Baohua Qi
YLYong Liu
Yong Liu
Future electron-positron collider experiments aim at the precise measurement of the Higgs boson, electroweak physics and the top quark. Based on the particle-flow paradigm, a novel highly granular crystal electromagnetic calorimeter (ECAL) is proposed to address major challenges from jet reconstruction and to achieve the optimal EM energy resolution of around 2–3%/E(GeV) with the homogeneous structure. Extensive R&D efforts have been carried out to evaluate the requirements and potentials of the crystal calorimeter concept from sensitive detection units to a full sub-detector system. The requirements on crystal candidates, photon sensors as well as readout electronics are parameterized and quantified in Geant4 full simulation. Experiments including characterizations of crystals and silicon photomultipliers (SiPMs) are performed to validate and improve the simulation results. The physics performance of the crystal ECAL is been studied with the particle flow algorithm “ArborPFA” which is also being optimized. Furthermore, a small-scale detector module with a crystal matrix and SiPM arrays is under development for future beam tests to study the performance for EM showers.

1 August 2023 in Journal of Instrumentation
Verified
Journal Article
Open access
BAB. Acar
B. Acar
GAG. Adamov
G. Adamov
CAC. Adloff
C. Adloff
SAS. Afanasiev
S. Afanasiev
NAN. Akchurin
N. Akchurin
XZX. Zhao
X. Zhao
As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures. The results on the electrical properties of the irradiated CE silicon sensors are presented.