Jingyan Xu

Dr. Jingyan Xu


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2009 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
JXJingyan Xu
Jingyan Xu
BTBenjamin M. W. Tsui
Benjamin M. W. Tsui
We consider electronic noise modeling in tomographic image reconstruction when the measured signal is the sum of a Gaussian distributed electronic noise component and another random variable whose log-likelihood function satisfies a certain linearity condition. Examples of such likelihood functions include the Poisson distribution and an exponential dispersion (ED) model that can approximate the signal statistics in integration mode X-ray detectors. We formulate the image reconstruction problem as a maximum-likelihood estimation problem. Using an expectation-maximization approach, we demonstrate that a reconstruction algorithm can be obtained following a simple substitution rule from the one previously derived without electronic noise considerations. To illustrate the applicability of the substitution rule, we present examples of a fully iterative reconstruction algorithm and a sinogram smoothing algorithm both in transmission CT reconstruction when the measured signal contains additive electronic noise. Our simulation studies show the potential usefulness of accurate electronic noise modeling in low-dose CT applications.

1 April 2009 in Journal of the American College of Radiology
Verified
Journal Article
Closed access
JXJingyan Xu
Jingyan Xu
MMMahadevappa Mahesh
Mahadevappa Mahesh
BTBenjamin M.W. Tsui
Benjamin M.W. Tsui

3 May 2010 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
JXJingyan Xu
Jingyan Xu
KTKatsuyuki Taguchi
Katsuyuki Taguchi
BTBenjamin M. W. Tsui
Benjamin M. W. Tsui
Projection data incompleteness arises in many situations relevant to X-ray computed tomography (CT) imaging. We propose a penalized maximum likelihood statistical sinogram restoration approach that incorporates the Helgason-Ludwig (HL) consistency conditions to accommodate projection data incompleteness. Image reconstruction is performed by the filtered-backprojection (FBP) in a second step. In our problem formulation, the objective function consists of the log-likelihood of the X-ray CT data and a penalty term; the HL condition poses a linear constraint on the restored sinogram and can be implemented efficiently via fast Fourier transform (FFT) and inverse FFT. We derive an iterative algorithm that increases the objective function monotonically. The proposed algorithm is applied to both computer simulated data and real patient data. We study different factors in the problem formulation that affect the properties of the final FBP reconstructed images, including the data truncation level, the amount of prior knowledge on the object support, as well as different approximations of the statistical distribution of the available projection data. We also compare its performance with an analytical truncation artifacts reduction method. The proposed method greatly improves both the accuracy and the precision of the reconstructed images within the scan field-of-view, and to a certain extent recovers the truncated peripheral region of the object. The proposed method may also be applied in areas such as limited angle tomography, metal artifacts reduction, and sparse sampling imaging.

23 March 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JXJingyan Xu
Jingyan Xu
FNFrédéric Noo
Frédéric Noo
The past decade has seen the rapid growth of model based image reconstruction (MBIR) algorithms, which are often applications or adaptations of convex optimization algorithms from the optimization community. We review some state-of-the-art algorithms that have enjoyed wide popularity in medical image reconstruction, emphasize known connections between different algorithms, and discuss practical issues such as computation and memory cost. More recently, deep learning (DL) has forayed into medical imaging, where the latest development tries to exploit the synergy between DL and MBIR to elevate the MBIR's performance. We present existing approaches and emerging trends in DL-enhanced MBIR methods, with particular attention to the underlying role of convexity and convex algorithms on network architecture. We also discuss how convexity can be employed to improve the generalizability and representation power of DL networks in general.

16 February 2011 in Medical Physics
Verified
Journal Article
Closed access
PDF file
KTKatsuyuki Taguchi
Katsuyuki Taguchi
JXJingyan Xu
Jingyan Xu
SSSomesh Srivastava
Somesh Srivastava
BTBenjamin M. W. Tsui
Benjamin M. W. Tsui
JCJochen Cammin
Jochen Cammin
QTQiulin Tang
Qiulin Tang

27 December 2023 in Pattern Recognition Letters
Verified
Journal Article
Closed access
JXJingyan Xu
Jingyan Xu