Gian Paolo Ussia

Prof. Gian Paolo Ussia

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2012 in European Heart Journal
Verified
Journal Article
Open access
PDF file
GUGian Paolo Ussia
Gian Paolo Ussia
MBMarco Barbanti
Marco Barbanti
APAnna Sonia Petronio
Anna Sonia Petronio
GTGiuseppe Tarantini
Giuseppe Tarantini
FEFederica Ettori
Federica Ettori
OIon behalf of the CoreValve Italian Registry Investigators
on behalf of the CoreValve Italian Registry Investigators
The paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA). From the Italian CoreValve registry, 181 who underwent TAVI from June 2007 to August 2008 and eligible for 3-year follow-up were analysed. All outcomes were defined according to the Valve Academic Research Consortium. All-cause mortality at 1, 2, and 3 years was 23.6, 30.3, and 34.8%, respectively. Cardiovascular death at 1, 2, and 3 years was 11.2, 12.1, and 13.5%, respectively. The actuarial survival free from a composite of death, major stroke, myocardial infarction, and life-threatening bleeding was 69.6% at 1 year, 63.5% at 2 years, and 59.7% at 3 years. Patients with renal insufficiency had a higher mortality at 3-year follow-up (49.0 vs. 29.2%, P = 0.007); moreover, patients experiencing post-procedural major or life-threatening bleeding had a higher rate of mortality already seen at 30 days (21.6 vs. 2.8%; P < 0.001) and this result was sustained at 3-year follow-up (62.2 vs. 27.7%; P < 0.001). Mean pressure gradients decreased from 52.2 ± 18.1 mmHg (pre-TAVI) to 10.3 ± 3.1 mmHg (1-year post-TAVI) (P < 0.001); aortic valve area increased from 0.6 ± 0.2 cm2 (pre-TAVI) to 1.8 ± 0.4 cm2 (1-year post-TAVI); these results remained stable over the 3 years of follow-up. Paravalvular leak was observed in the majority of patients. There were no cases of progression to moderate or severe regurgitation. No cases of structural valve deterioration were observed. This multicentre study demonstrates that TAVI with the 18-Fr CoreValve ReValving System is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic stenosis up to 3-year follow-up. Non-cardiac causes accounted for the majority of deaths at follow-up.

1 December 2011 in The American Journal of Cardiology
Verified
Journal Article
Closed access
GUGian Paolo Ussia
Gian Paolo Ussia
MSMarilena Scarabelli
Marilena Scarabelli
MMMassimiliano Mulè
Massimiliano Mulè
MBMarco Barbanti
Marco Barbanti
KSKunal Sarkar
Kunal Sarkar
CTCorrado Tamburino
Corrado Tamburino

1 March 2011 in JACC
Verified
Journal Article
Closed access
GUGian Paolo Ussia
Gian Paolo Ussia
MBMarco Barbanti
Marco Barbanti
ARAngelo Ramondo
Angelo Ramondo
APAnna Sonia Petronio
Anna Sonia Petronio
FEFederica Ettori
Federica Ettori
CTCorrado Tamburino
Corrado Tamburino

1 August 2013 in International Journal of Cardiology
Verified
Journal Article
Closed access
GUGian Paolo Ussia
Gian Paolo Ussia
MBMarco Barbanti
Marco Barbanti
ACAntonio Colombo
Antonio Colombo
GTGiuseppe Tarantini
Giuseppe Tarantini
APAnna Sonia Petronio
Anna Sonia Petronio
CICoreValve Italian Registry Investigators
CoreValve Italian Registry Investigators

8 March 2022 in Life
Verified
Journal Article
Open access
PDF file
ANAnnunziata Nusca
Annunziata Nusca
MVMichele Mattia Viscusi
Michele Mattia Viscusi
FPFrancesco Piccirillo
Francesco Piccirillo
AFAurelio De Filippis
Aurelio De Filippis
Antonio NennaAntonio Nenna
Antonio Nenna
GUGian Paolo Ussia
Gian Paolo Ussia
Despite the dramatic improvements of revascularization therapies occurring in the past decades, a relevant percentage of patients treated with percutaneous coronary intervention (PCI) still develops stent failure due to neo-atherosclerosis (NA). This histopathological phenomenon following stent implantation represents the substrate for late in-stent restenosis (ISR) and late stent thrombosis (ST), with a significant impact on patient’s long-term clinical outcomes. This appears even more remarkable in the setting of drug-eluting stent implantation, where the substantial delay in vascular healing because of the released anti-proliferative agents might increase the occurrence of this complication. Since the underlying pathophysiological mechanisms of NA diverge from native atherosclerosis and early ISR, intra-coronary imaging techniques are crucial for its early detection, providing a proper in vivo assessment of both neo-intimal plaque composition and peri-strut structures. Furthermore, different strategies for NA prevention and treatment have been proposed, including tailored pharmacological therapies as well as specific invasive tools. Considering the increasing population undergoing PCI with drug-eluting stents (DES), this review aims to provide an updated overview of the most recent evidence regarding NA, discussing pathophysiology, contemporary intravascular imaging techniques, and well-established and experimental invasive and pharmacological treatment strategies.

13 May 2009 in European Heart Journal
Verified
Journal Article
Open access
PDF file
GUGian Paolo Ussia
Gian Paolo Ussia
MMMassimiliano Mulè
Massimiliano Mulè
MBMarco Barbanti
Marco Barbanti
Valeria CammalleriValeria Cammalleri
Valeria Cammalleri
MSMarilena Scarabelli
Marilena Scarabelli
CTCorrado Tamburino
Corrado Tamburino
To assess the NYHA class and the quality of life (QoL) scores after percutaneous aortic valve implantation (PAVI) with the 18-Fr CoreValve® prosthesis. From April 2007 until August 2008, 57 consecutive patients with aortic stenosis were evaluated for PAVI. Of these, 30 patients with successfully prosthesis implantation had more than 5-month follow-up. QoL assessment was realized with the SF-12v2® Health-Survey, a simple questionnaire designed for self-administration that provides easily interpretable scales for physical [physical component summary (PCS)] and mental [mental component summary (MCS)] health. The questionnaire was administered before and 5 months after PAVI. All 30 patients had a marked upgrading in haemodynamic and echocardiographic parameters (peak-to-peak gradient from 64 ± 23 to 2 ± 0.4; P < 0.001; aortic valve area index from 0.3 ± 0.1 to 0.9 ± 0.3; P < 0.001), with an improvement in New York Heart Association (NYHA) class at discharge and after 5 months. Mean pre-operative SF-12v2® scores showed a severe impairment of perceived quality of life compared with general Italian population >75 years, both for physical (PCS-baseline 28.5 vs. 37.9, P < 0.001) and mental scores (MCS-baseline 37.8 vs. 45.4, P < 0.001). After 5 months, a striking improvement in both scores (PCS 41.3–MCS 48.3; P < 0.001) was observed. Our preliminary results show a marked short-term improvement in functional status and physical and mental health in patients underwent PAVI.