Current investigations on space tethers include their application to space debris deorbiting, specifically on the set of manoeuvres performed by a chaser tug to change the orbital parameters of a target body. Targets can be cooperative spacecraft at the end of their life or uncontrolled objects such as defunct satellites without clearly available capturing interfaces. In this latter case, a link joining tug and target may be misaligned with the target body inertia axes, influencing the attitude of both bodies; in case of rigid links, torques transmitted during tugging operations may overcome the tug attitude control system. This issue is clearly less significant in case of non-rigid connections, such as tethers; furthermore, with such connections the chaser can remain at a safe distance from the target during the whole deorbiting operation. On the other side, the initial phase of tethered space debris removal manoeuvres can be influenced by transient events, such as sudden tether tension spikes, that may cause longitudinal and lateral oscillations and, in case of resonance with the target attitude dynamics, could represent a serious issue for tug safety. In this paper it is proposed to provide the tug with a tether deployer mechanism capable to perform reel-in and reel-out, smoothing loads transmission to the target and damping oscillations. This concept is validated through a representative test campaign performed with the SPAcecRraft Testbed for Autonomous proximity operatioNs experimentS (SPARTANS) on a low friction table. A prototype of the deployer is manufactured and the deployment and rewind of a thin aluminium tape tether is proven. Test results include the verification of the tether visco-elastic characteristics with the direct measurement of spikes and oscillations and the estimation of the proposed system damping capabilities.
A vision based instrument able to measure the position and orientation of a spacecraft is described and calibrated from a metrological point of view. The instrument comprises a simple camera which observes the external surface of the satellite provided with fiducial markers and a software procedure which employs a closed-form and direct solution of the Perspective from three Points problem. Several tests are performed to evaluate the calibration curves and the output uncertainty. The employed experimental set-up is able to impose known and precise linear and/or rotational movements to a satellite mock-up to highlight different operative conditions.
9 November 2011 in IEEE Transactions on Plasma Science
A two-stage mission to place a spacecraft (SC) below the Jovian radiation belts, using a spinning bare tether with plasma contactors at both ends to provide propulsion and power, is proposed. Capture by Lorentz drag on the tether, at the periapsis of a barely hyperbolic equatorial orbit, is followed by a sequence of orbits at near-constant periapsis, drag finally bringing the SC down to a circular orbit below the halo ring. Although increasing both tether heating and bowing, retrograde motion can substantially reduce accumulated dose as compared with prograde motion, at equal tether-to-SC mass ratio. In the second stage, the tether is cut to a segment one order of magnitude smaller, with a single plasma contactor, making the SC to slowly spiral inward over several months while generating large onboard power, which would allow multiple scientific applications, including in situ study of Jovian grains, auroral sounding of upper atmosphere, and space- and time-resolved observations of surface and subsurface.
To mitigate the growing problem of space debris, current international guidelines require spacecraft in Low Earth Orbit (LEO) to implement post-mission disposal strategies to be deorbited within 25 years from the end of their operative life. Electrodynamic tethers are an effective and promising option for deorbiting as they do not require fuel consumption. However, the success of this new technology also depends on the dynamic stability of thin tape-shaped tethers during both deployment and deorbiting phases. This is where precise measurement of damping characteristics of thin tape-shaped tethers comes in. This paper presents an innovative experimental setup and analysis methods for precisely measuring the damping ratio of a thin (thickness 50 microns) tape-shaped tether made of PEEK intended for use in electrodynamic tethers applications. To capture longitudinal oscillations during dynamic tests, we employed a laser vibrometer and explored four different methods of experimental data analysis, comparing and describing them in detail in the paper. We also conducted an uncertainty analysis in line with ISO GUM. The experimental results show good agreement among the four methods used to estimate the damping ratio with the most precise method involving nonlinear regression applied to all the experimental data. A Monte Carlo analysis was carried out considering the most significant sources of uncertainty. The smallest uncertainty interval is ±1% of the estimated damping ratio, with a 95% confidence level, using this method.