Dariusz Sztafrowski

Prof. Dr. Dariusz Sztafrowski


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2023 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
RKRobert Kaznowski
Robert Kaznowski
DSDariusz Sztafrowski
Dariusz Sztafrowski
The paper presents issues related to the problems that need to be overcome in order to achieve the goal of achieving a high share of renewable energy from wind and solar energy in the country's power system. The basic problem is to ensure high flexibility of EPS in the situation of high variability of generation of EE from renewable sources. The authors highlighted new energy sources and systems ensuring the flexibility of EPS.

1 January 2018 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
DSDariusz Sztafrowski
Dariusz Sztafrowski
The article presents the results of the in vitro studies which were carried out to determine the effect of constant magnetic field (SMF - static magnetic field) and organic chemical called Busulfan on the level of apoptosis of human leukemia cells HL-60 in the study populations. The mortality increase of cells HL-60 in the case of a constant magnetic field and busulfan with respect to groups of cells treated with cytostatic only has been discovered. The use of a constant magnetic field as a supporting factor in therapy with selected cytostatic has been proposed.

1 February 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
DSDariusz Sztafrowski
Dariusz Sztafrowski
JJJ Jakubaszko
J Jakubaszko
The paper presents the influence of 50 Hz magnetic field on selected biochemical parameters of human blood. The analysis was carried out in test environment created in the department of Electrical Power Engineering at Wroclaw University of Science and Technology, using magnetic field of 50 Hz, with values and homogeneity equivalent to these of electrical power objects. The study was conducted in collaboration with the Wroclaw Medical University.

1 January 2018 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
DSDariusz Sztafrowski
Dariusz Sztafrowski
One of the phenomena accompanying the operation of high voltage power lines is the electric corona effect. Corona discharge is responsible among others for electrical losses, formation of ozone and the chemical compounds leading to accelerated corrosion of wires of the overhead power lines. On the basis of the analysis in the article indicated the possibility of limiting the occurrence of the corona effect what is beneficial to the durability of the phase wires, and reduction of losses in transmission of electrical power.

9 December 2022 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
JGJacek Gumiela
Jacek Gumiela
AKAndrzej Kocielski
Andrzej Kocielski
DSDariusz Sztafrowski
Dariusz Sztafrowski
Podczas projektowania przesyłowych linii elektroenergetycznych wykonuje się wiele szczegółowych analiz oddziaływania tych obiektów na środowisko. Do typowych zadań należy obliczeniowa identyfikacja rozkładu generowanego pola elektromagnetycznego w zakresie jego składowej elektrycznej oraz magnetycznej dla różnych warunków środowiskowych związanych z temperaturą powietrza oraz wpływem sadzi, która może wystąpić na przewodach linii elektroenergetycznej. Wraz ze wzrostem mocy obliczeniowej współczesnych komputerów ułatwione jest przeprowadzanie analiz dla wszelkich możliwych stanów pracy linii. W niniejszym artykule autorzy podjęli się oszacowania wpływu przemieszczeń przewodów linii wywołanych parciem wiatru na zmiany rozkładu generowanych pól elektromagnetycznych oraz określenie miejsc występowania lokalnych maksimów i minimów natężenia pola dla kilku wybranych konfiguracji przewodów..

12 January 2023 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
DSDariusz Sztafrowski
Dariusz Sztafrowski
ESEdyta Szczuka
Edyta Szczuka
Prezentowana praca jest kontynuacją wcześniej prowadzonych badań oceny wpływu PEM o częstotliwości 50Hz na organizm dokonywanych w oparciu o wyniki pomiaru aktywności elektrodermalnej (ang. electrodermal activity - EDA). W prowadzonych obecnie badaniach terenowych dokonano wstępnych pomiarów EDA w biologicznie aktywnych punktach zlokalizowanych na dłoniach i stopach, w warunkach narażenia na środowiskowy wpływ PEM.