David A A Gabriel

Dr. David A A Gabriel

Brock University, St. Catharines, Ontario, Canada

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2006 in Sports Medicine
Verified
Journal Article
Closed access
PDF file
David A A GabrielDavid A A Gabriel
David A A Gabriel
GKGary Kamen
Gary Kamen
GFGail Frost
Gail Frost

1 November 2020 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Closed access
JIJ. Greig Inglis
J. Greig Inglis
David A A GabrielDavid A A Gabriel
David A A Gabriel
This study evaluated potential sex differences in motor unit (MU) behaviour at maximal and submaximal force outputs. Forty-eight participants, 24 females and 24 males, performed isometric dorsiflexion contractions at 20%, 40%, 60%, 80%, and 100% of a maximum voluntary contraction (MVC). Tibialis anterior electromyography was recorded both by surface and intramuscular electrodes. Compared with males, females had a greater MU discharge rate (MUDR) averaged across all submaximal intensities (Δ 0.45 pps, 2.56%). Males exhibited greater increases in MUDR above 40% MVC, surpassing females at 100% MVC (p’s < 0.01). Averaged across all force outputs, females had a greater incidence of doublet and rapid discharges and a greater percentage of MU trains with doublet and rapid (5–10 ms) discharges (Δ 75.55% and 61.48%, respectively; p’s < 0.01). A subset of males (n = 8) and females (n = 8), matched for maximum force output, revealed that females had even greater MUDR (Δ 1.38 pps, 7.47%) and percentage of MU trains with doublet and rapid discharges (Δ 51.62%, 56.68%, respectively; p’s < 0.01) compared with males at each force output, including 100% MVC. Analysis of the subset of strength-matched males and females suggest that sex differences in MU behaviour may be a result of females needing to generate greater neural drive to achieve fused tetanus. Novelty Females had higher MUDRs and greater percentage of MU trains with doublets across submaximal force outputs (20%–80% MVC). Differences were even greater for a strength matched subset. Differences in motor unit behaviour may arise from musculoskeletal differences, requiring greater neural drive in females.

30 June 2009 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
David A A GabrielDavid A A Gabriel
David A A Gabriel
GKGary Kamen
Gary Kamen

1 September 2021 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Closed access
JIJ. Greig Inglis
J. Greig Inglis
David A A GabrielDavid A A Gabriel
David A A Gabriel
The purpose of this study was to evaluate the relationship between the variability in the motor unit inter-pulse interval and force steadiness at submaximal and maximal force outputs between the sexes. Twenty-four male and 24 female participants were recruited to perform isometric dorsiflexion contractions at 20, 40, 60, 80, and 100% maximum voluntary contraction. Tibialis anterior myoelectric signal was recorded by an intramuscular electrode. Females had lower force steadiness (coefficient of variation of force (CoV-Force), 27.3%, p < 0.01) and a greater coefficient of variation of motor unit action potential inter-pulse interval (CoV-IPI), compared with males (9.6%, p < 0.01). There was no significant correlation between the normalized CoV-IPI and CoV-Force (r = 0.19, p > 0.01), but there was a significant repeated measures correlation between the raw scores for root-mean-square force error and the standard deviation of motor unit discharge rate (r = 0.65, p < 0.01). Females also had a greater incidence of doublet discharges on average across force levels (p < 0.01). The sex differences may result from motor unit behaviours (i.e., doublet and rapid discharges, synchronization, rate coding or recruitment), leading to lower force steadiness and greater CoV-IPI in females. Novelty: Sex differences in force steadiness may be due to neural strategies. Females have lower force steadiness compared with males. Greater incidence of doublet discharges in females may result in lesser force steadiness.

1 January 2007 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
David A A GabrielDavid A A Gabriel
David A A Gabriel
SLSteven M. Lester
Steven M. Lester
SLSean A. Lenhardt
Sean A. Lenhardt
ECEdward D.J. Cambridge
Edward D.J. Cambridge

10 December 2010 in Medical Engineering & Physics
Verified
Journal Article
Closed access
David A A GabrielDavid A A Gabriel
David A A Gabriel
ACAnita Christie
Anita Christie
JIJ. Greig Inglis
J. Greig Inglis
GKGary Kamen
Gary Kamen
A pattern classification method based on five measures extracted from the surface electromyographic (sEMG) signal is used to provide a unique characterization of the interference pattern for different motor unit behaviours. This study investigated the sensitivity of the five sEMG measures during the force gradation process. Tissue and electrode filtering effects were further evaluated using a sEMG model. Subjects (N=8) performed isometric elbow flexion contractions from 0 to 100% MVC. The sEMG signals from the biceps brachii were recorded simultaneously with force. The basic building block of the sEMG model was the detection of single fibre action potentials (SFAPs) through a homogeneous, equivalent isotropic, infinite volume conduction medium. The SFAPs were summed to generate single motor unit action potentials. The physiologic properties from a well-known muscle model and motor unit recruitment and firing rate schemes were combined to generate synthetic sEMG signals. The following pattern classification measures were calculated: mean spike amplitude, mean spike frequency, mean spike slope, mean spike duration, and the mean number of peaks per spike. Root-mean-square amplitude and mean power frequency were also calculated. Taken together, the experimental data and modelling analysis showed that below 50% MVC, the pattern classification measures were more sensitive to changes in force than traditional time and frequency measures. However, there are additional limitations associated with electrode distance from the source that must be explored further. Future experimental work should ensure that the inter-electrode distance is no greater than 1cm to mitigate the effects of tissue filtering.