The surface plasmon resonance (SPR) sensor is an important tool widely used for studying binding kinetics between biomolecular species. The SPR approach offers unique advantages in light of its real-time and label-free sensing capabilities. Until now, nearly all established SPR instrumentation schemes are based on single- or several-channel configurations. With the emergence of drug screening and investigation of biomolecular interactions on a massive scale these days for finding more effective treatments of diseases, there is a growing demand for the development of high-throughput 2-D SPR sensor arrays based on imaging. The so-called SPR imaging (SPRi) approach has been explored intensively in recent years. This review aims to provide an up-to-date and concise summary of recent advances in SPRi. The specific focuses are on practical instrumentation designs and their respective biosensing applications in relation to molecular sensing, healthcare testing, and environmental screening.
The coronavirus disease 2019 (COVID-19) pandemic, caused by the new severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus, has posed a threat to public health worldwide. Also, influenza virus has caused a large number of deaths annually. Since co-infection of SARS-CoV-2 and influenza virus, which share similar symptoms, hampers current treatment efficiency, multiple simultaneous detection of these viruses is needed to provide the right treatment for patients. We developed a microfluidic disc-direct RT-qPCR (dirRT-qPCR) assay for rapid multiplex detection of SARS-CoV-2, influenza A and B viral infection in pharyngeal swab samples in an automated manner. Choices of the DNA polymerase, concentrations of dTPs and MgCl2 were characterized to optimize the assay. A detection limit of 2 × 101 copies per reaction was found in all three viral RNAs with as little as 2 μL of swab samples. The accuracy of our assay was evaluated with 2127 clinical swab samples of infection with these three viruses and healthy controls, and it possessed a consistency rate of 100, 99.54 and 99.25% in SARS-CoV-2, influenza A and B detection in comparison to standard RT-qPCR. The reported scheme of our assay is capable of screening other viral infections for up to 16 targets simultaneously. The whole diagnosis could be completed in 1.5 hours after simple sample loading by a non-technical expert. This constitutes an enabling strategy for large-scale point-of-care screening of multiple viral infections, which ultimately lead to a pathway for resolving the critical issue of early diagnosis for the prevention and control of viral outbreaks.
More than a decade after the outbreak of human coronaviruses (HCoVs) SARS in Guangdong province and Hong Kong SAR of China in 2002, there is still no reoccurrence, but the evolution and recombination of the coronaviruses in this region are still unknown. Therefore, surveillance on the prevalence and the virus variation of HCoVs circulation in this region is conducted. A total of 3298 nasopharyngeal swabs samples were collected from cross-border children ( 37.5 °C), from 2014 May to 2015 Dec. Viral nucleic acids were analyzed and sequenced to study the prevalence and genetic diversity of the four human coronaviruses. The statistical significance of the data was evaluated with Fisher chi-square test. 78 (2.37%; 95%CI 1.8-2.8%) out of 3298 nasopharyngeal swabs specimens were found to be positive for OC43 (36;1.09%), HKU1 (34; 1.03%), NL63 (6; 0.18%) and 229E (2;0.01%). None of SARS or MERS was detected. The HCoVs predominant circulating season was in transition of winter to spring, especially January and February and NL63 detected only in summer and fall. Complex population with an abundant genetic diversity of coronaviruses was circulating and they shared homology with the published strains (99-100%). Besides, phylogenetic evolutionary analysis indicated that OC43 coronaviruses were clustered into three clades (B,D,E), HKU1 clustered into two clades(A,B) and NL63 clustered into two clades(A,B). Moreover, several novel mutations including nucleotides substitution and the insertion of spike of the glycoprotein on the viral surface were discovered. The detection rate and epidemic trend of coronaviruses were stable and no obvious fluctuations were found. The detected coronaviruses shared a conserved gene sequences in S and RdRp. However, mutants of the epidemic strains were detected, suggesting continuous monitoring of the human coronaviruses is in need among cross-border children, who are more likely to get infected and transmit the viruses across the border easily, in addition to the general public.
As in all RNA viruses, influenza viruses change and mutate constantly because their RNA polymerase has no proofreading ability. This poses a serious threat to public health nowadays. In addition, traditional pathogen-based detection methods may not be able to report an infection from an unknown type or a subtype of virus if its nucleotide sequence is not known. Because of these factors, targeting host microRNA signatures may be an alternative to classify infections and distinguish types of pathogens as microRNAs are produced in humans shortly after infection. Although this approach is in its infant stage, there is an urgent need to develop a rapid reporter assay for microRNA for disease control and prevention. As a proof of concept, we report herein for the first time a non-PCR MARS (MicroRNA-RNase-SPR) assay to detect the microRNA miR-29a-3p from human subjects infected with influenza virus H1N1 by surface plasmon resonance (SPR). In our MARS assay, RNase H is employed to specifically hydrolyze the RNA probes immobilized on the gold surface where they hybridize with its cognate target cDNAs miR-29a-3p, where it was formed from reverse transcription with mature miR-29a-3p specific stem-looped primers. After the digestion of the RNA probe by RNase H, the intact cDNA was released from the RNA–DNA hybrid and bound to a new RNA probe for another enzymatic reaction cycle to amplify signals. With assay optimization, the detection limit of our MARS assay for miR-29a-3p was found to be 1 nM, and this new assay could be completed within 1 hour without thermal cycling. This non-PCR assay with high selectivity for mature microRNA provides a new platform for rapid disease diagnosis, quarantine and disease control.