Due to insufficient ventilation, public toilets present high risks for cross-infection. The study investigated 61 public toilets to identify the causes and locations of biological contaminated sources. Airborne and surface bacterial contamination, carbon dioxide concentration, and surface ammonia levels were measured. Both bacterial contamination and CO2 are higher in non-ventilated toilets compared to their ventilated counterparts. Bacteria colony forming units (CFUs) in a public toilet with poor ventilation can reach 5 times the number of CFUs outside of the toilet. This suggests that non-ventilated public toilets present a higher risk of cross-infection. Areas near all kinds of sanitary equipment (toilet bowls, squat toilets and urinals) were highly contaminated, indicating that enhanced cleaning regimes are necessary. Further, lidless trash bins present a higher risk as contaminated matter within the trash bins is not inhibited from being released into the environment. Ventilation and cleaning need to be improved to mitigate the risk of cross-infection in public toilets.
Due to insufficient ventilation, public toilets have become incubators for cross-infection during the pandemic. WHO has proposed an approach to improve indoor ventilation, including ventilation in isolated spaces like toilets, by applying the 10L/s/person criteria, and keeping fans running for effective ventilation. However, less air inflow in many public toilets causes the insufficient ventilation. We have ever found many colony forming units (CFUs) staying surrounding floor and junctures, and the inside of a lid-less trash can in the toilet. If the minimal exhaust air is not equal to inlet air, the bioaerosol will stay in the toilets. Therefore, the speed of air inflow is suggested to be somewhat higher and reach 0.5m/s or more to facilitate ventilation in public toilets and reduce the risk of cross-infection.
As climate change and urbanization intensify, heritage buildings are increasingly exposed to both environmental and anthropogenic stressors, making their preservation more complex and costly. This study presents an integrated approach that combines Computational Fluid Dynamics (CFD) simulations, Heritage Building Information Modeling (H-BIM), and microclimate monitoring, enhanced by statistical analysis, to assess deterioration risks in historic structures. By establishing optimized monitoring intervals and evaluating environmental variability, we assess the potential to reduce sensor density without compromising data fidelity. Real-time observations are paired with predictive modeling to identify vulnerable zones early on. Our findings indicate that data-driven preventive monitoring, supported by advanced simulations, offers a practical and scalable strategy for reducing long-term deterioration and enhancing conservation planning.