Liao Jianwei

Mr. Liao Jianwei


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2022 in Electronics
Verified
Journal Article
Open access
PDF file
HYHaibo Yang
Haibo Yang
LJLiao Jianwei
Liao Jianwei
HWHulin Wang
Hulin Wang
CGChaosong Gao
Chaosong Gao
ZLzhang ling
zhang ling
Chengxin ZhaoChengxin Zhao
Chengxin Zhao
The External-target Experiment (CEE) at the Cooling Storage Ring of the Heavy-Ion Research Facility in Lanzhou (HIRFL-CSR) will be the first large-scale experiment in nuclear physics independently developed in China covering the GeV energy regime. The beam monitor located at the center front of the CEE accurately measures the position of the particles with a few tens of um accuracy in a non-interceptive way. This unique advantage significantly improves the accuracy of the particle track reconstructions. This beam monitor’s readout electronics consist of the Front-end module (FEM), Readout Control Module (RCM), and Clock Synchronization module (CSM). Twhe novel Topmetal series pixel sensors directly collect the ionized charge along the track of the ion beam while it passes through the gas in the beam monitor. Lab test proves that the readout electronics have an INL of less than 1%. In addition, the prototype beam monitor can measure the position of the 40Ar beam of 320 MeV/u with a resolution of ~6.9 μm. This paper will discuss the design, characterization, and test of the readout electronics.

9 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YSYingdong Song
Yingdong Song
HYHaibo Yang
Haibo Yang
YZYuezhao Zhang
Yuezhao Zhang
LJLiao Jianwei
Liao Jianwei
YJYanhao Jia
Yanhao Jia
Chengxin ZhaoChengxin Zhao
Chengxin Zhao
To monitor the position and profile of therapeutic carbon beams in real-time, in this paper, we proposed a system called HiBeam-T. The HiBeam-T is a time projection chamber (TPC) with forty Topmetal-II- CMOS pixel sensors as its readout. Each Topmetal-II- has 72 × 72 pixels with the size of 83 μm × 83 μm. The detector consists of the charge drift region and the charge collection area. The readout electronics comprise three Readout Control Modules and one Clock Synchronization Module. This Hibeam-T has a sensitive area of 20 × 20 cm and can acquire the center of the incident beams. The test with a continuous 80.55 MeV/u 12C6+ beam shows that the measurement resolution to the beam center could reach 6.45 μm for unsaturated beam projections.