Luis Hector Quintero Hernandez

Dr. Luis Hector Quintero Hernandez

University of Guadalajara, Guadalajara, Jalisco, Mexico
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2022 in Molecules
Verified
Journal Article
Open access
PDF file
Oscar Ignacio Cervantes ArreolaOscar Ignacio Cervantes Arreola
Oscar Ignacio Cervantes Arreola
ZLZaira López
Zaira López
NCNorberto Casillas
Norberto Casillas
Peter KnauthPeter Knauth
Peter Knauth
NCNayeli Checa
Nayeli Checa
Mario E. CanoMario E. Cano
Mario E. Cano
A ferrofluid with 1,2-Benzenediol-coated iron oxide nanoparticles was synthesized and physicochemically analyzed. This colloidal system was prepared following the typical co-precipitation method, and superparamagnetic nanoparticles of 13.5 nm average diameter, 34 emu/g of magnetic saturation, and 285 K of blocking temperature were obtained. Additionally, the zeta potential showed a suitable colloidal stability for cancer therapy assays and the magneto-calorimetric trails determined a high power absorption density. In addition, the oxidative capability of the ferrofluid was corroborated by performing the Fenton reaction with methylene blue (MB) dissolved in water, where the ferrofluid was suitable for producing reactive oxygen species (ROS), and surprisingly a strong degradation of MB was also observed when it was combined with H2O2. The intracellular ROS production was qualitatively corroborated using the HT-29 human cell line, by detecting the fluorescent rise induced in 2,7-dichlorofluorescein diacetate. In other experiments, cell metabolic activity was measured, and no toxicity was observed, even with concentrations of up to 4 mg/mL of magnetic nanoparticles (MNPs). When the cells were treated with magnetic hyperthermia, 80% of cells were dead at 43 °C using 3 mg/mL of MNPs and applying a magnetic field of 530 kHz with 20 kA/m amplitude.

1 August 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
EVErnesto Edgar Mazon Valadez
Ernesto Edgar Mazon Valadez
EVE. Villa-Martínez
E. Villa-Martínez
AHA. Hernández-Sámano
A. Hernández-Sámano
TFTeodoro CORDOVA - FRAGA
Teodoro CORDOVA - FRAGA
JIJosé de Jesús Ibarra-Sánchez
José de Jesús Ibarra-Sánchez
Mario E. CanoMario E. Cano
Mario E. Cano
A scanning system for specific absorption rate of ferrofluids with superparamagnetic nanoparticles is presented in this study. The system contains an induction heating device designed and built with a resonant inverter in order to generate magnetic field amplitudes up to 38 mT, over the frequency band 180-525 kHz. Its resonant circuit involves a variable capacitor with 1 nF of capacitance steps to easily select the desired frequency, reaching from 0.3 kHz/nF up to 5 kHz/nF of resolution. The device performance is characterized in order to compare with the theoretical predictions of frequency and amplitude, showing a good agreement with the resonant inverters theory. Additionally, the setup is tested using a synthetic iron oxide with 10 ± 1 nm diameter suspended in liquid glycerol, with concentrations at 1%. Meanwhile, the temperature rise is measured to determine the specific absorption rate and calculate the dissipated power density for each f. This device is a suitable alternative to studying ferrofluids and analyzes the dependence of the power absorption density with the magnetic field intensity and frequency.

20 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
DGDulce A. Guzmán-Rocha
Dulce A. Guzmán-Rocha
TFTeodoro CORDOVA - FRAGA
Teodoro CORDOVA - FRAGA
JBJosé J. Bernal-Alvarado
José J. Bernal-Alvarado
ZLZaira López
Zaira López
FCFrancisco A. Cholico
Francisco A. Cholico
Mario E. CanoMario E. Cano
Mario E. Cano
An exhaustive characterization of the physicochemical properties of gum arabic (GA)-coated Fe3O4 magnetic nanoparticles was conducted in this work. These nanoparticles were obtained via the in-situ coprecipitation method (a fast single-step method) in two GA:Fe ratios, 10:1 and 20:1, respectively. Several experimental techniques were applied in the characterization process, all of them described below. Using Transmission Electron Microcopy images, they were shown to have spherical-like morphology with 11 nm diameter. The Fourier Transform Infrared spectra confirmed the attachment of the GA on the surface of the magnetic nanoparticles (MNPs), providing good colloidal stability from pH 7 to 8. The thickness of the coatings (1.7 nm and 1.1 nm) was determined using thermogravimetric measurements. A high specific absorption rate and superparamagnetic properties were determined using alternant and static magnetic fields, respectively. The GA-coated MNPs were non-cytotoxic, according to tests on HT-29 human intestine cells. Additionally, HT-29 cells were exposed to magnetic fluid hyperthermia at 530 kHz, and the induction of cell death by the magnetic field, due to the heating of GA-coated MNP, was observed.

5 August 2022 in Coatings
Verified
Journal Article
Open access
PDF file
AGAna Gabriela González-Gutiérrez
Ana Gabriela González-Gutiérrez
NCNorberto Casillas
Norberto Casillas
ZLZaira López
Zaira López
OCOscar Cervantes
Oscar Cervantes
Peter KnauthPeter Knauth
Peter Knauth
Mario E. CanoMario E. Cano
Mario E. Cano
In this work, tetrahydroxyquinone (THQ) was used for the first time to coat iron oxide nanoparticles (IONPs) and to carry out in vitro experiments in magnetic hyperthermia. Synthesis by co-precipitation resulted in spherical IONPs with a core diameter of 13 ± 3 nm and covered by a 0.5 nm thick coat of THQ, which provided them with a reasonably good zeta potential of ζ = −28 ± 2 mV at pH = 7.3, and thus colloidal stability. The magnetic properties of the THQ-coated IONPs are promising: the low coercive field of Hc = 7 Oe, the high magnetic saturation of Ms = 70.5 emu/g and the low blocking temperature of Tb = 273 K indicate superparamagnetic characteristics at room temperature. Additionally, a high specific absorption rate SAR = 135 W/g (at 300 Oe and 530 kHz) was determined. Cell biological experiments using the human cell line HT-29 evidenced negligible cytotoxicity up to 2 mg/mL. Magnetic hyperthermia (MHT) assays demonstrated fast and reliable heating and reduced the metabolic activity of the cells to 42% upon reaching 42 °C within 15 min. The production of ROS by THQ-coated IONPs could not be detected, which may indicate a reduction in the undesired side effects caused by oxidative stress. Considering these good physicochemical and cell biological properties, this ferrofluid is a promising candidate for the initiation of in vivo experiments for cancer treatment by MHT in murine models.

5 May 2025 in Langmuir
Verified
Journal Article
Closed access
CRCarolina Livier Recio-Colmenares
Carolina Livier Recio-Colmenares
DODaniela Ortiz-Ríos
Daniela Ortiz-Ríos
FEFernando Espinola-Portilla
Fernando Espinola-Portilla
LHLuis Hector Quintero Hernandez
Luis Hector Quintero Hernandez
SGSergio Gómez-Salazar
Sergio Gómez-Salazar
María Guadalupe Pérez-GarcíaMaría Guadalupe Pérez-García
María Guadalupe Pérez-García

21 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
SRSaray Rosales
Saray Rosales
RHRodolfo Hernández-Gutíerrez
Rodolfo Hernández-Gutíerrez
AOAlma Oaxaca
Alma Oaxaca
ZLZaira López
Zaira López
NCNorberto Casillas
Norberto Casillas
Mario E. CanoMario E. Cano
Mario E. Cano
In this work, the cell line SW620-GFP has been used in a complete magnetic hyperthermia assay, from the preparation of the ferrofluid with folate-coated iron oxide nanoparticles to in vivo experiments. The physical and chemical characterization of the nanoparticles evidenced their superparamagnetic behaviour, an average diameter of 12 ± 4 nm, a 2 nm coat thickness, and a high-power loss density. The main innovation of the work is the exclusive capability of viable SW620-GFP cells to emit fluorescence, enabling fast analysis of both, cell viability in vitro with an epifluorescence microscope and tumour size and shape in vivo in a non-invasive manner using the iBox technology. Moreover, with this imaging technique, it was possible to demonstrate the successful tumour size reduction in mice applying magnetic hyperthermia three times a week over 3 weeks.