Jian Zhou

Jian Zhou


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2016 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
PDF file
JZJian Zhou
Jian Zhou
FYFan Yang
Fan Yang
GJGuanchao Jiang
Guanchao Jiang
JWJun Wang
Jun Wang
Near-infrared (NIR) fluorescence guided surgery is an emerging technique. This technique uses the combination of dyes and NIR imaging devices to expand the visible spectrum. Thus it can provide more anatomic and functional information, and may facilitate a more complete resection of cancer, or better protection of important normal structures. Recently, significant progress has been made in the field of NIR fluorescence guided thoracic surgery. This may lead to better prognosis and health-economic outcomes. In this article, the current studies of indocyanine green (ICG) based NIR fluorescence guided thoracic surgeries are reviewed. The applications are classified into four categories, which are applications based on blood supply, lymphatic drainage, the enhanced permeability and retention (EPR) effect, and the other mechanisms.

15 October 2022 in The Lancet Regional Health - Western Pacific
Verified
Journal Article
Open access
YLYun Li
Yun Li
RFRongrong Fan
Rongrong Fan
YLYunwei Lu
Yunwei Lu
HLHuayan Li
Huayan Li
XLXianping Liu
Xianping Liu
JWJun Wang
Jun Wang
With the outbreak of the coronavirus disease 2019 (COVID-19), nurses have won well-deserved recognition for their indispensable roles in providing humane and professional healthcare for patients. However, by the nature of their role working at the forefront of patient care, nurses are prone to experiencing mental health consequences. Therefore, we pay attention to measuring the magnitude of psychological symptoms and identifying associated factors among nurses in China. We launched a nationwide, cross-sectional survey of nurses who worked in secondary or tertiary hospitals and public or private hospitals from 30 provinces in China. The prevalence and severity of symptoms of burnout, depression, and anxiety were investigated, respectively. Multivariable logistic regression analyses were performed to identify factors associated with each psychological symptom. A total of 138 279 respondents who worked in 243 hospitals completed this survey. A substantial proportion of nurses reported symptoms of burnout (34%), depression (55·5%), and anxiety (41·8%). In line with the disproportionality of economic development, we noted that the middle or western region was an independent risk factor for depression and anxiety. Compared with those working in the secondary hospital, nurses who worked in tertiary hospitals were associated with a higher likelihood of burnout and depression. Nurses are experiencing emotional, physical, and mental exhaustion during the COVID-19 epidemic. Governments and health policymakers need to draw attention to reinforcing prevention and ameliorating countermeasures to safeguard nurses' health. The strategic consulting project of the Chinese Academy of Engineering [2021-32-5]. Advanced Institute of Infomation Technology, Peking University, Zhejiang Province [2020-Z-17]

1 January 2018 in Theranostics
Verified
Journal Article
Open access
PDF file
KHKunshan He
Kunshan He
JZJian Zhou
Jian Zhou
FYFan Yang
Fan Yang
CCChongwei Chi
Chongwei Chi
HLHao Li
Hao Li
JWJun Wang
Jun Wang
The sympathetic nervous system controls and regulates the activities of the heart and other organs. Sympathetic nervous system dysfunction leads to disease. Therefore, intraoperative real-time imaging of thoracic sympathetic nerves (ITSN) would be of great clinical significance for diagnosis and therapy. The aim of this experimental study was to evaluate the feasibility and validity of intraoperative ITSN using indocyanine green (ICG).

27 July 2017 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
YMYamin Mao
Yamin Mao
CCChongwei Chi
Chongwei Chi
FYFan Yang
Fan Yang
JZJian Zhou
Jian Zhou
KHKunshan He
Kunshan He
JTJie Tian
Jie Tian
Current surgical procedures lack high-sensitivity intraoperative imaging guidance, leading to undetected micro tumours. In vivo near-infrared (NIR) fluorescence imaging provides a powerful tool for identifying small nodules. The aim of this study was to examine our experience of using 2 different NIR devices in pulmonary resection surgery. From August 2015 to October 2016, 36 patients with lung nodules underwent NIR fluorescence imaging thoracoscopic surgery. Two NIR devices: a D-Light P system and a SUPEREYE system were used. Patients were administered an injection of indocyanine green (ICG) through the peripheral vein 24 h preoperatively. During surgery, traditional white-light thoracoscopic exploration was performed first, followed by ICG-fluorescent-guided exploration. All detected nodules were resected and examined by a pathologist. Of the 36 patients, 76 nodules were resected. ICG-fluorescent imaging identified 68 nodules during in vivo exploration. The mean signal-to-background ratio of lung nodules in NIR exploration was 3.29 ± 1.81. The application of NIR devices led to the detection of 9 additional nodules that were missed using traditional detection methods (1 mm computed tomography scan and white-light thoracoscopic exploration) in 7 patients (19.4%). Four of the 9 nodules were confirmed as malignant or atypical adenomatous hyperplasia (44.4%). The other 5 nodules were confirmed as false-positive nodules. The sensitivities and positive predictive values of the ICG-fluorescent imaging for lung tumours were 88.7% and 92.6%, respectively. This study demonstrated the feasibility and safety of using ICG-fluorescent imaging for multiple lung nodules identification in video-assisted thoracoscopic surgery pulmonary resection. NCT02611245.

25 September 2017 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
FYFeng Yang
Feng Yang
JZJian Zhou
Jian Zhou
HLHao Li
Hao Li
FYFan Yang
Fan Yang
RXRongxin Xiao
Rongxin Xiao
JWJun Wang
Jun Wang
Chylothorax is an infrequent but relatively serious complication after lung cancer surgery. Finding the leakage site and identifying the thoracic duct (TD) are the key points of surgical intervention for chylothorax. In this study, for the first time, we demonstrated near-infrared fluorescence imaging with indocyanine green (ICG) in video-assisted thoracoscopic surgery (VATS) intervention for chylothorax in humans. This study included 4 patients diagnosed with chylothorax after lung cancer surgery who underwent VATS intervention; 0.2 mg/kg of ICG was injected subcutaneously into the bilateral inguinal region approximately 30 min before surgery. The D-light P® near-infrared thoracoscope was used for intraoperative fluorescence imaging. All patients underwent VATS intervention on the right side. Chyle leakage points were detected at the point of dissection of the station of the 4R lymph node behind the azygos vein in 3 patients and at the adjacent point of prophylactic ligation of the TD in 1 patient. The fluorescent hotspot of ICG leakage was detected first. The signal-to-background ratio of the TD or chyle averaged 4.41 (range 2.31–6.72). The TD fluorescent signals lasted for at least 1 h. With the guidance of real-time fluorescence lymphography, the fistulas and the main trunk of the TD were identified and double ligated. Small branches of the TD were occasionally detected and ligated. Chylothorax was managed successfully by surgical interventions in all patients. Near-infrared fluorescence imaging with ICG provided highly sensitive and real-time imaging of the TD in VATS intervention for chylothorax in humans. NCT02611245.

1 February 2019 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
WBWhitney S. Brandt
Whitney S. Brandt
WYWanpu Yan
Wanpu Yan
JZJian Zhou
Jian Zhou
KTKay See Tan
Kay See Tan
JMJoseph Montecalvo
Joseph Montecalvo
DJDavid Jones
David Jones