Manuel Siegl

Mr. Manuel Siegl

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MSManuel Siegl
Manuel Siegl
MKManuel Kämpf
Manuel Kämpf
DGDominik Geier
Dominik Geier
BABjörn Andreeßen
Björn Andreeßen
SMSebastian Max
Sebastian Max
TBThomas Matthias Becker
Thomas Matthias Becker
A soft sensor concept is typically developed and calibrated for individual bioprocesses in a time-consuming manual procedure. Following that, the prediction performance of these soft sensors degrades over time, due to changes in raw materials, biological variability, and modified process strategies. Through automatic adaptation and recalibration, adaptive soft sensor concepts have the potential to generalize soft sensor principles and make them applicable across bioprocesses. In this study, a new generalized adaptation algorithm for soft sensors is developed to provide phase-dependent recalibration of soft sensors based on multiway principal component analysis, a similarity analysis, and robust, generalist phase detection in multiphase bioprocesses. This generalist soft sensor concept was evaluated in two multiphase bioprocesses with various target values, media, and microorganisms. Consequently, the soft sensor concept was tested for biomass prediction in a Pichia pastoris process, and biomass and protein prediction in a Bacillus subtilis process, where the process characteristics (cultivation media and cultivation strategy) were varied. High prediction performance was demonstrated for P. pastoris processes (relative error = 6.9%) as well as B. subtilis processes in two different media during batch and fed-batch phases (relative errors in optimized high-performance medium: biomass prediction = 12.2%, protein prediction = 7.2%; relative errors in standard medium: biomass prediction = 12.8%, protein prediction = 8.8%).

24 June 2024 in Biotechnology and Bioprocess Engineering
Verified
Journal Article
Open access
PDF file
MSManuel Siegl
Manuel Siegl
DGDominik Geier
Dominik Geier
BABjörn Andreeßen
Björn Andreeßen
SMSebastian Max
Sebastian Max
EMEsther Mose
Esther Mose
TBThomas Becker
Thomas Becker
Innovative soft sensor concepts can recalibrate automatically when the prediction performance decreases due to variations in raw materials, biological variability, and changes in process strategies. For automatic recalibration, data sets are selected from a data pool based on distance-based similarity criteria and then used for calibration. Nevertheless, the most appropriate data sets often are not reliably selected due to variances in the location of landmarks and process length of the bioprocesses. This can be overcome by synchronization methods that align the historical data sets with the current process and increase the accuracy of automatic selection and recalibration. This study investigated two different synchronization methods (dynamic time warping and curve registration) as preprocessing for the automatic selection of data sets using a distance-based similarity criterion for soft sensor recalibration. The prediction performance of the two soft sensors without synchronization was compared to the variants with synchronization and evaluated by comparing the normalized root mean squared errors. Curve registration improved the prediction performance on average by 24% (Pichia pastoris) and 9% (Bacillus subtilis). Using dynamic time warping, no substantial improvement in prediction performance could be achieved. A major factor behind this was the loss of information due to singularities caused by the changing process characteristics. The evaluation was performed on two target variables of real bioprocesses: biomass concentration prediction in P. pastoris and product concentration prediction in B. subtilis.

1 September 2009
Verified
Conference Paper
Closed access
MSManuel Siegl
Manuel Siegl
HEH. D. R. Evans
H. D. R. Evans
EDE. J. Daly
E. J. Daly
GSGiovanni Santin
Giovanni Santin
PNP. Nieminen
P. Nieminen
PBP. Buhler
P. Buhler
The Standard Radiation Environment Monitor (SREM) is a particle detector developed for wide use on ESA spacecraft. It is flying on several ESA missions, most recently the Herschel and Planck space telescopes. Using data from the SREM unit on PROBA-1 in LEO, pitch angle anisotropies in the inner Van Allen belt are investigated. The sensitivity of the SREM to pitch angle induced flux anisotropies can be linked to the directional response function of the SREM, obtained using GRAS/Geant4 Monte-Carlo simulations. The directional response function is combined with an anisotropic version of the AP8 model (based on the Badhwar-Konradi anisotropy distribution) to yield improved count predictions. The importance of considering flux anisotropies is shown for both short-term data and long-term integrated counts. Significant improvements to the AP8 model can be realised.