Valerio Antonio Arcobelli

Dr. Valerio Antonio Arcobelli

DEI, University of Bologna, Bologna, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
AMAlberto Marfoglia
Alberto Marfoglia
FNFilippo Nardini
Filippo Nardini
VAValerio Antonio Arcobelli
Valerio Antonio Arcobelli
SMSerena Moscato
Serena Moscato
Sabato MelloneSabato Mellone
Sabato Mellone
Antonella CarbonaroAntonella Carbonaro
Antonella Carbonaro
Given the exponential increase in clinical data, which accounts for around 30% of global data volume, effective information management has become crucial to ensuring robust interoperability. This trend is further expedited by implementing consumer-oriented Internet of Things platforms, contributing to the growth of the $8.3 trillion healthcare industry. These advancements, combined with challenges such as heterogeneous data formats and a lack of incentives, necessitate the development of pragmatic infrastructures and tools that harness contemporary clinical standards like Fast Healthcare Interoperability Resources (FHIR). This study aims to present a modular conversion pipeline employing a templating strategy for translating clinical data into the FHIR model. Emphasis is placed on utilizing a standard mapping specification like FHIR Mapping Language. This ensures essential properties such as platform independence, portability, and code reusability. The pipeline was developed incrementally, dividing its core functionalities into five modules: Input, Refinement, Mapping, Validation, and Export. These were subsequently validated by converting a dataset from a prosthetic fitting and rehabilitation center to demonstrate the approach's validity in a real-world data context. A total of 1962 hospital stay records of 1006 unique patients were converted successfully to 15 distinct types of FHIR resources. The successful conversion states the pipeline's effectiveness, additionally showcasing its capabilities for enhancing semantic interoperability and facilitating the reuse of real-world data. Our approach emerges as a modular data conversion framework that addresses the limitations of existing solutions, making significant contributions to the creation of standardized, interoperable, and high-quality clinical datasets that serve as a foundation for further work.

12 November 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
MZMatteo Zauli
Matteo Zauli
LPLorenzo Mistral Peppi
Lorenzo Mistral Peppi
LBLuca Di Bonaventura
Luca Di Bonaventura
VAValerio Antonio Arcobelli
Valerio Antonio Arcobelli
ASAlberto Spadotto
Alberto Spadotto
LMLuca De Marchi
Luca De Marchi
The aim of this work is to present a preliminary study for the design of a digital auscultation system, i.e., a novel wearable device for patient chest auscultation and a digital stethoscope. The development and testing of the electronic stethoscope prototype is reported with an emphasis on the description and selection of sound transduction systems and analog electronic processing. The focus on various microphone technologies, such as micro-electro-mechanical systems (MEMSs), electret condensers, and piezoelectronic diaphragms, intends to emphasize the most suitable transducer for auscultation. In addition, we report on the design and development of a digital acquisition system for the human body for sound recording by using a modular device approach in order to fit the chosen analog and digital mics. Tests were performed on a designed phantom setup, and a qualitative comparison between the sounds recorded with the newly developed acquisition device and those recorded with two commercial digital stethoscopes is reported.

21 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
VAValerio Antonio Arcobelli
Valerio Antonio Arcobelli
MZMatteo Zauli
Matteo Zauli
GGGiulia Galteri
Giulia Galteri
LCLuca Cristofolini
Luca Cristofolini
Lorenzo ChiariLorenzo Chiari
Lorenzo Chiari
Sabato MelloneSabato Mellone
Sabato Mellone
This paper reports the architecture of a low-cost smart crutches system for mobile health applications. The prototype is based on a set of sensorized crutches connected to a custom Android application. Crutches were instrumented with a 6-axis inertial measurement unit, a uniaxial load cell, WiFi connectivity, and a microcontroller for data collection and processing. Crutch orientation and applied force were calibrated with a motion capture system and a force platform. Data are processed and visualized in real-time on the Android smartphone and are stored on the local memory for further offline analysis. The prototype’s architecture is reported along with the post-calibration accuracy for estimating crutch orientation (5° RMSE in dynamic conditions) and applied force (10 N RMSE). The system is a mobile-health platform enabling the design and development of real-time biofeedback applications and continuity of care scenarios, such as telemonitoring and telerehabilitation.

20 July 2024 in Scientific Data
Verified
Journal Article
Open access
PDF file
VAValerio Antonio Arcobelli
Valerio Antonio Arcobelli
SMSerena Moscato
Serena Moscato
PPPierpaolo Palumbo
Pierpaolo Palumbo
AMAlberto Marfoglia
Alberto Marfoglia
FNFilippo Nardini
Filippo Nardini
Sabato MelloneSabato Mellone
Sabato Mellone
Lower limb amputation is a medical intervention which causes motor disability and may compromise quality of life. Several factors determine patients’ health outcomes, including an appropriate prosthetic provision and an effective rehabilitation program, necessitating a thorough quantitative observation through different data sources. In this context, the role of interoperability becomes essential, facilitating the reuse of real-world data through the provision of structured and easily accessible databases. This study introduces a comprehensive 10-year dataset encompassing clinical features, mobility measurements, and prosthetic knees of 1006 trans-femoral amputees during 1962 hospital stays for rehabilitation. The dataset is made available in both comma-separated values (CSV) format and HL7 Fast Healthcare Interoperability Resources (FHIR)-based representation, ensuring broad utility and compatibility for researchers and healthcare practitioners. This initiative contributes to advancing community understanding of post-amputation rehabilitation and underscores the significance of interoperability in promoting seamless data sharing for meaningful insights into healthcare outcomes.

15 May 2026 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MVMaria Giovanna Verrengia
Maria Giovanna Verrengia
VAValerio Antonio Arcobelli
Valerio Antonio Arcobelli
GLGiada Lullini
Giada Lullini
SMSabato Mellone
Sabato Mellone
SMStefano Mazzoleni
Stefano Mazzoleni
SOSilvia Orlandi
Silvia Orlandi
Purpose: This umbrella review aimed to assess the effectiveness of lower extremity robotic devices in clinical settings by analyzing motor and non-motor rehabilitation outcomes across different neurological conditions, including stroke, spinal cord injury, multiple sclerosis, and Parkinson’s disease. Methods: A systematic search of literature published in English over the past twelve years was conducted using four major databases (PubMed, Scopus, Cochrane Library, and Web of Science). The search focused on reviews addressing the use of lower-limb robotic devices in patients with neurological diseases. Only reviews that followed standardized protocols and reported quantitative motor and/or non-motor rehabilitation outcomes were included. Extracted information included demographic characteristics, experimental procedures, and numerical outcomes related to motor and non-motor functions (e.g., walking test scores, clinical scale ratings). Results: A total of 33 reviews met the inclusion criteria. Stroke was the most frequently studied condition, whereas Parkinson’s disease and multiple sclerosis were rarely addressed. Findings related to stroke suggested that robotic rehabilitation may provide benefits over conventional therapy, with statistically significant improvements in some cases. In contrast, evidence for spinal cord injury, Parkinson’s disease, and multiple sclerosis was limited and inconsistent. Conclusions: Overall, lower-limb robotic devices show promise in neurorehabilitation, particularly for post-stroke recovery. However, further research is required to standardize intervention protocols, assess cost-effectiveness, and better understand patient and therapist experiences to support broader clinical adoption.

1 April 2026 in JMIR Rehabilitation and Assistive Technologies
Verified
Journal Article
Open access
MGMarica Giardini
Marica Giardini
Ilaria ArcolinIlaria Arcolin
Ilaria Arcolin
VAValerio Antonio Arcobelli
Valerio Antonio Arcobelli
MPMichela Picardi
Michela Picardi
Sabato MelloneSabato Mellone
Sabato Mellone
MGMarco Godi
Marco Godi
Background: The Timed Up and Go (TUG) test is widely used to assess mobility and fall risk in older adults and orthopedic patients. Its instrumented variant (iTUG), based on inertial measurement units, enables an objective quantification of motor performance and can even be implemented using smartphone technology. However, its broader clinical adoption remains limited by concerns about reliability, feasibility, and the interpretability of the extracted parameters. Objective: This study aimed to evaluate the test-retest reliability of variables derived from a single-sensor iTUG in orthopedic inpatients undergoing rehabilitation and to determine whether a subset of reliable sensor-based metrics can support a multidimensional assessment of functional mobility and discriminate among common orthopedic conditions. Methods: We recruited 104 inpatients at discharge from a rehabilitation ward after total hip arthroplasty, total knee arthroplasty, or femur fracture. Each participant performed the iTUG test on 2 consecutive days using a smartphone-based solution consisting of an inertial measurement unit placed on the lower back. From 100 extracted variables, those with excellent test-retest reliability (intraclass correlation coefficient ≥0.75) were retained. Exploratory factor analysis was used to identify underlying mobility domains, and linear discriminant analysis with 10-fold cross-validation tested their ability to classify diagnostic groups. Results: Out of 100 iTUG-derived variables, 36 demonstrated excellent test-retest reliability, and 25 were retained for multivariate analysis. Exploratory factor analysis identified 5 factors—walking ability, pace or rhythm, sit-to-walk smoothness, turning ability, and mediolateral angular stability—explaining 80.8% of the total variance. These factors showed good classification accuracy (68%) and achieved an area under the curve of 0.86 and an overall mean accuracy of 0.68 (SD 0.14) for distinguishing among total hip arthroplasty, total knee arthroplasty, and femur fracture. In contrast, total iTUG duration alone yielded an area under the curve of 0.62. All patients used walking aids, and gait variables were more reliable than jerk-based or coordination metrics. Conclusions: The single-sensor iTUG provides reliable and clinically informative metrics that go beyond traditional stopwatch timing, enabling a multidimensional view of functional mobility in orthopedic patients. The approach is feasible, interpretable, and compatible with real-world mobile health apps, supporting personalized rehabilitation monitoring and future integration into digital decision support systems.