Nguyen Nhat Tung

Dr. Nguyen Nhat Tung


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
QTQuoc-Tuan Tran
Quoc-Tuan Tran
NTNguyen Nhat Tung
Nguyen Nhat Tung
TTThien Phong Tran
Thien Phong Tran
MPMinh Cong Pham
Minh Cong Pham
MLMinh Tri Le
Minh Tri Le
The energy transition has introduced significant challenges to the resilience and reliability of existing power distribution networks, particularly in the face of high penetration of renewable energy resources (RESs), e.g., photovoltaic (PV) and wind systems. Unlike traditional power systems, RESs are intermittent and decentralized, leading to complexities in network restoration during outages. Developing advanced restoration methods is essential to ensure rapid recovery, maintain grid stability, and optimize the use of distributed energy resources (DERs). With that, this paper presents an optimization-based restoration strategy in a self-healing distribution network (SHDN) with high penetration of renewable energies. The proposed method employs the coordinated voltage control (CVC) technique to avoid voltage violations while maximizing power generation. The paper then illustrates the restoration strategy based on an islanded grid with robust black start capabilities and advanced control systems such as grid-forming inverters (GFI). GFIs can reduce optimization efforts, be applied to real-time restoration processes, and reduce uncertainty in restoration models. After that, several EMT simulations are conducted to evaluate the dynamic system restoration process for a resilient black start. Finally, the CVC strategy and restoration of an islanded grid are validated using a real medium-voltage (MV) grid.

25 August 2022 in Algorithms
Verified
Journal Article
Open access
PDF file
VNVan-Vinh Nguyen
Van-Vinh Nguyen
NTNguyen Nhat Tung
Nguyen Nhat Tung
QNQuang-Thuan Nguyen
Quang-Thuan Nguyen
Van-Hai BuiVan-Hai Bui
Van-Hai Bui
Wencong SuWencong Su
Wencong Su
The primary function of hybrid direct current circuit breakers (HCBs) is to quickly interrupt fault currents to protect high-voltage direct current (HVDC) systems. To enhance the reliability and stability of HVDC systems, optimal design of HCBs is required to minimize the peak fault current, interruption time, and recovery time. Therefore, this study develops a multi-objective genetic algorithm (MOGA)-based optimization model to identify the optimal parameters for HCBs. The MOGA model consists of three objective functions that provide trade-offs among reductions in the peak fault current, the interruption time, and the recovery time. The proposed algorithm is verified with a novel HCB topology using inverse current injection techniques. The performance of the HCB topology with the optimal parameters is validated in the MATLAB/Simulink environment. In addition, a comparison study between the optimal design of an HCB using the proposed algorithm and a typical HCB model is presented in this study to show the effectiveness of the proposed optimization method. Our simulation results show that the optimal parameter design of HCBs significantly reduces the magnitude of the peak fault current and operating time, thus maintaining the safe and stable operation of the entire system.

1 April 2025 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
TCTran Hung Cuong
Tran Hung Cuong
NTNguyen Nhat Tung
Nguyen Nhat Tung
AAAn Thi Hoai Thu Anh
An Thi Hoai Thu Anh
This paper will present a reactive power control method for medium voltage power grids based on the modular multilevel converter (MMC) structure. In particular, the MMC converter applies control algorithms to operate as a D-STATCOM device. A proportional–integral (PI) controller combined with an improved nearest level modulation (NLM) method performs the system control process. The purpose is to create sinusoidal voltage levels on the alternating current (AC) side to generate or absorb reactive power according to load requirements. This will ensure that the amount of reactive power for the load node is always within the allowable value and improve voltage quality, increasing the power factor for the load. Verifying and evaluating results are performed on MATLAB/Simulink software.

1 January 2026 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
NTNguyen Nhat Tung
Nguyen Nhat Tung
NCNguyen Cong Chinh
Nguyen Cong Chinh
TNThuan Thanh Nguyen
Thuan Thanh Nguyen
This study introduces an effective method for the optimal integration of distributed renewable energy sources, specifically wind turbine (WT) units and photovoltaic (PV) units, into distribution networks. The optimization objective is to simultaneously minimize energy import costs, system power losses, and voltage deviations, while satisfying operational constraints such as bus voltages, branch currents, penetration levels, and harmonic indices under conditions where the load demand and power output of the renewable sources vary seasonally. To objectively evaluate the suggested method, the performance of the coyote optimization algorithm (COA) is compared with three other robust metaheuristic methods, namely the energy valley optimizer (EVO), the artificial bee colony (ABC) algorithm, and the equilibrium optimizer (EO). The optimization process is implemented and evaluated in two distinct scenarios: The first considers a distribution network with only linear loads, while the second integrates both linear and nonlinear loads. The achieved results demonstrate that the COA outperforms the other optimization algorithms, yielding higher‐quality solutions.