Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD) or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices.
To evaluate the optical coherence tomography angiography (OCTA) parameters in patients with diabetic retinopathy following panretinal photocoagulation (PRP). Eleven eyes of 6 patients with very severe nonproliferative diabetic retinopathy (NPDR) or early proliferative diabetic retinopathy (PDR) were recruited in this prospective interventional pilot study. All patients underwent OCTA imaging at baseline, and choroidal flow, foveal avascular zone (FAZ), retinal thickness, and vascular density were measured at baseline. Three months after treatment, OCTA was repeated, and the alteration in variables was analyzed. The FAZ area remained unchanged following treatment, (P = 0.75). Retinal thickness increased along (P = 0.02) with an increase in vascular density in the superficial and deep foveal area and the macular temporal sector (P = 0.007, 0.03 and 0.049, respectively). Choroidal flow surface area was unchanged (P = 0.10). In this study, foveal vascular density increased and FAZ remained unchanged after PRP for diabetic retinopathy.
Purpose: To evaluate and compare three different techniques of inverted internal limiting membrane (ILM) flap in the treatment of large idiopathic full-thickness macular hole. Methods: In a comparative interventional case series, 72 eyes from 72 patients with large (> 400 μm) full-thickness macular hole were randomly enrolled into three different groups: group A – hemicircular ILM peel with temporally hinged inverted flap; group B – circular ILM peel with temporally hinged inverted flap; and group C – circular ILM peel with superior inverted flap. Best-corrected visual acuity (BCVA), anatomical closure rate, and ellipsoid zone (EZ) or external limiting membrane (ELM) defects were evaluated preoperatively, at week 1, and months 1, 3 and 6 after surgery. Results: There were 24 eyes in group A, 23 in group B, and 25 in group C. In all three groups, larger diameter macular hole was associated with worse preoperative visual acuity (r=0.625, P<0.001). Mean BCVA improved significantly in all three groups 6 months after surgery (0.91vs 0.55, p<0.001). 6 months after surgery, mean BCVA improved from 0.91 logMAR to 0.52±0.06 in group A, 0.90 to 0.53±0.06 in group B, and 0.91 to 0.55±0.11 in group C. In group A vs. B vs. C, improvement of BCVA was 0.380±0.04 vs. 0.383±0.04 vs. 0.368±0.11 logMAR, with no statistically significant difference between groups (P=0.660). The rate of successful hole closure was 87.5% vs. 91.3% vs. 100%. Although the closure rate was 100% in Group C (circular ILM peel with superiorly hinged inverted flap), this difference was not statistically significant (P=0.115). Conclusion: ILM peel with an inverted flap is a highly effective procedure for the treatment of large, full-thickness macular hole. Different flap techniques have comparable results, indicating that the technique can be chosen based on surgeon preference.