Belwin Edward Jeyaraj

Dr. Belwin Edward Jeyaraj

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in ISA Transactions
Verified
Journal Article
Closed access
BJBelwin Edward Jeyaraj
Belwin Edward Jeyaraj
Rajasekar NatarajanRajasekar Natarajan
Rajasekar Natarajan
KSK. Sathiyasekar
K. Sathiyasekar
NSN. Senthilnathan
N. Senthilnathan
RSR. Sarjila
R. Sarjila

1 June 2017 in Energy Procedia
Verified
Journal Article
Open access
WPW J Praiselin
W J Praiselin
BJBelwin Edward Jeyaraj
Belwin Edward Jeyaraj

16 August 2024 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
VGVarathan G.
Varathan G.
BJBelwin Edward Jeyaraj
Belwin Edward Jeyaraj

1 January 2016 in Procedia Computer Science
Verified
Journal Article
Open access
APAvagaddi Prasad
Avagaddi Prasad
BJBelwin Edward Jeyaraj
Belwin Edward Jeyaraj
Transmission systems (TS) plays a major role in electrical power systems. The interruption caused to the consumer because of TS faults is substantial. So TS needs a proper protection scheme to ensure continuous power supply to the consumers. This study proposes a novel scheme using wavelet technique for classification of faults in TS. In order to do so, the proposed scheme uses current measurements of just one side of the transmission line. Simulations are performed under different fault conditions using MATLAB. The stability of the proposed scheme under various cases is tested andreliable results have been obtained

1 March 2016
Verified
Conference Paper
Closed access
JSJ. Gowri Shankar
J. Gowri Shankar
BJBelwin Edward Jeyaraj
Belwin Edward Jeyaraj
This Paper presents a 15 level Asymmetrical Cascaded H bridge multilevel inverter Topology for Photovoltaic system. In this system Symmetrical and Asymmetrical Multilevel inverter (MLI) is utilized. In Symmetrical MLI, the DC source magnitude are equal ie., 50Vdc, 50Vdc & 50Vdc., where as in Asymmetrical MLI the DC source Magnitude are unequal and it is designed with binary form of voltage such as 50Vdc, 100Vdc & 200Vdc. Comparing both the MLI, Asymmetrical MLI generates a number of output voltage level with same number of Power semiconductor switches. The phase Disposition Pulse Width Modulation (PD-PWM) technique is used for controlling the Power semiconductor switches in MLI. The results are verified in both MATLAB and PROTEUS.

8 March 2018 in International Journal of Intelligent Systems and Applications
Verified
Journal Article
Closed access
PDF file
WPW. J. Praiselin
W. J. Praiselin
BJBelwin Edward Jeyaraj
Belwin Edward Jeyaraj