When approaching infected lead removal in cardiac device-related infective endocarditis (CDRIE), a surgical consideration for large (>20 mm) vegetations is recommended. We report our experience with the removal of large CDRIE vegetations using the AngioVac system, as an alternative to conventional surgery. We retrospectively reviewed all infected lead extractions performed with a prior debulking using the AngioVac system, between October 2016 and April 2022 at our institution. A total of 13 patients presented a mean of 2(1) infected leads after a mean of 5.7(5.7) years from implantation (seven implantable cardioverter-defibrillators, four cardiac resynchronization therapy-defibrillators, and two pacemakers). The AngioVac system was used as a venous–venous bypass in six cases (46.2%), venous–venous ECMO-like circuit (with an oxygenator) in five (38.5%), and venous–arterial ECMO-like circuit in two cases (15.4%). Successful (>70%) aspiration of the vegetations was achieved in 12 patients (92.3%) and an intraoperative complication (cardiac perforation) only occurred in 1 case (7.7%). Subsequent lead extraction was successful in all cases, either manually (38.5%) or using mechanical tools (61.5%). The AngioVac system is a promising effective and safe option for large vegetation debulking in CDRIE. Planning the extracorporeal circuit design may represent the optimal strategy to enhance the tolerability of the procedure and minimize adverse events.
We propose a patient-tailored strategy that considers the risk for postoperative right heart failure, utilizing the percutaneous ProtekDuo cannula (Livanova, London, UK) in an innovative way to perform cardiopulmonary bypass during LVAD implantation in ECMO patients. Our novel protocol is based on the early intra-operative use of the ProtekDuo cannula, adopting the distal lumen as the pulmonary vent and the proximal lumen as the venous inflow cannula during cardiopulmonary bypass. This configuration is rapidly switched to the standard fashion to provide planned postoperative temporary right ventricular support, in selected patients at high risk of right ventricular failure. From September 2020 to June 2022, six patients were supported with the ProtekDuo cannula during and after an intracorporeal LVAD implantation (five of which were minimally invasive): four HeartMate III (Abbott, U.S.A.) and two HVAD (Medtronic Inc, MN). In all cases, the ProtekDuo cannula was correctly positioned and removed without complications after a median period of 8 days. Non-fatal bleeding (bronchial hemorrhage) occurred in one patient (17%) during biventricular support. Thirty-day mortality was 0%. From this preliminary work, our novel strategy demonstrated to be a feasible solution for planned minimally invasive right ventricular support in ECMO patients scheduled for a durable LVAD implantation.
Background: When heart transplantation and myocardial recovery are unlikely, patients presenting with biventricular cardiogenic shock initially treated with extracorporeal membrane oxygenation (ECMO) may benefit from a mechanical support upgrade. In this scenario, a micro-invasive approach is proposed: the combination of the double-lumen ProtekDuo cannula (Livanova, London, UK) and the Impella 5.5 (Abiomed, Danvers, MA) trans-aortic pump that translates into a hybrid BiVAD. Methods: All consecutive ECMO patients presenting with biventricular cardiogenic shock and ineligibility to heart transplantation from August 2022 were prospectively enrolled. The clinical course, procedural details, and in-hospital events were collected via electronic medical records. Results: A total of three patients, who were temporarily not eligible for heart transplantation or durable LVAD due to severe acute pneumonia and right ventricular (RV) dysfunction, were implanted with a hybrid BiVAD. This strategy provided high-flow biventricular support while pulmonary function ameliorated. Moreover, by differentially sustaining the systemic and pulmonary circulation, it allowed for a more adequate reassessment of RV function. All the patients were considered eligible for isolated durable LVAD and underwent less invasive LVAD implantation paired with a planned postoperative RVAD. In all cases, RV function gradually recovered and the RVAD was successfully removed. Conclusions: The Hybrid BiVAD represents an up-to-date micro-invasive mechanical treatment of acute biventricular failure beyond ECMO. Its rationale relies on more physiological circulation across the lungs, the complete biventricular unloading, and the possibility of including an oxygenator in the circuit. Finally, the independent and differential control of pulmonary and systemic flows allows for more accurate RV function evaluation for isolated durable LVAD eligibility reassessment.