Purpose Frontal sinus fractures are relatively common injuries presenting to trauma units. The optimal treatment of frontal sinus fractures remains controversial. Bicoronal approach is commonly used to obtain full exposure of both frontal bones and to repair any intracranial trauma; however, this approach requires long operative time and could lead to a long-lasting visible scar, alopecia, and paresthesias. In addition, patients have to stay in hospital for several days with this method. Endoscopic approach, less invasive than bicoronal method, has a steep learning curve. In this article, we suggest a simple reduction method in frontal sinus anterior wall fracture using the tapper instrument. Methods Between 2005 and 2011, a transcutaneous reduction of closed anterior table frontal sinus fracture using a tapper instrument was performed in 13 patients. This group consists of 10 men and 3 women, and the mean age was 27.5 years. Under general anesthesia, the point that the tapper would be placed is marked considering the fracture site shown on computed tomographic scan and the clinically depressed area. A 3-mm slit incision was made just above the marked point. After drilling through this incision, the tapper device was applied to the depressed bone segment. Simply pulling out the tapper, the depressed frontal sinus anterior wall segment was reduced. Results Contour deformities were restored completely in all patients without any recurrent displacement, and all patients were satisfied with the results. There were no complications such as infection and uncontrollable sinus bleeding, but pneumocephalus had occurred in 1 patient owing to the posterior table injury that happened during the tapper-applying procedure. We treated him with preventive antibiotics, and he completely recovered after 1 week. Conclusions This method has better aesthetic results, shorter operative time, and minimal hospital stay than other surgical approaches. Although it contains minimal risk of posterior wall injury, considering not only surgical results but also patients’ satisfaction, the authors suggest that this simple percutaneous reduction method using the tapper instrument would be the treatment of choice in the frontal sinus anterior wall fractures.
Corrective rhinoplasty for functional and aesthetic recovery relies much on the use of grafts. This may be effectively accomplished with alloplastic materials; however, certain circumstances mandate the use of autologous grafts. Septal and auricular cartilages are inadequate for dorsal augmentation of the Asian nose. Here, we present our experiences with the correction of nasal deformities using chondro-osseous rib grafts, aiming at anatomic and functional reconstruction of the nose dorsum, especially the keystone area. The deformity was the result of trauma in 16 patients, postrhinoplastic deformities in 7, and congenital deformities in 5 patients. All the patients underwent reconstructive rhinoplasty using the sixth or seventh rib complex graft. Overall, functional and aesthetic outcome was satisfactory in all patients. Rigid bony union, good nasal projection, and symmetry were obtained. Graft exposure, displacement, warping, and significant bone absorption were not observed. The seventh or sixth rib provided not only the greatest overall available length and thickness, but also less donor-site morbidity. In conclusion, using rib bone and cartilage combination graft as a single unit allowed more predictable and reliable reconstruction of the nose deformity than did the conventional dorsal grafts.
31 July 2009 in Journal of Plastic, Reconstructive & Aesthetic Surgery
The lateral arm flap is an alternative to the conventional radial forearm flap and has been widely used due to advancements in flap characteristics. Especially, the fasciocutaneous flap has been widely used in head and neck reconstruction due to its versatile characteristics and surgical feasibility. This flap has successfully undergone several useful modifications based on various anatomical studies. Here, the authors aimed to verify the versatility and reliability of free lateral arm flap reconstruction of numerous head and neck defects. Twelve patients (6 men and 6 women; mean age, 66 years) with various types of lateral arm flaps from May 2017 to April 2019 were included. The anatomical reconstruction area was widely distributed across the facial subunits, tongue and oral cavity, and hypopharynx, among others. The flap varied in size from 3 x 5 cm to 17 x 7 cm, and the average pedicle length was 5.58 cm. The versatility of the lateral arm flap enabled successful coverage of various defects in all cases. Among 12 patients, the donor site outcome was rated as excellent and good by 2 and 10 patients, respectively. Three patients complained of post-operative hypoesthesia, which was subsequently resolved. The lateral arm flap is a unique and extremely versatile soft tissue free flap. Its versatility facilitates continuous modification of the flap and its application in various areas in different forms with excellent contour outcomes. The authors successfully verified the evolving methods and advantages of lateral arm flaps in the treatment of various head and neck defects.