Hidekazu Takahashi

Prof. Dr. Hidekazu Takahashi

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
SLSasipin Lauvahutanon
Sasipin Lauvahutanon
MSMaho Shiozawa
Maho Shiozawa
HTHidekazu Takahashi
Hidekazu Takahashi
NINaohiko Iwasaki
Naohiko Iwasaki
MOMeiko Oki
Meiko Oki
MAMansuang Arksornnukit
Mansuang Arksornnukit
Lauvahutanon S, et al. Restor Dent Endod. 2017 Feb;42(1):9-18. https://doi.org/10.5395/rde.2017.42.1.9

21 June 2014 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
MSMaho Shiozawa
Maho Shiozawa
HTHidekazu Takahashi
Hidekazu Takahashi
YAYuya Asakawa
Yuya Asakawa
NINaohiko Iwasaki
Naohiko Iwasaki

22 August 2013 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
MSMaho Shiozawa
Maho Shiozawa
HTHidekazu Takahashi
Hidekazu Takahashi
NINaohiko Iwasaki
Naohiko Iwasaki

1 January 2023 in Journal of Prosthodontic Research
Verified
Journal Article
Open access
PDF file
YTYumi Tsuchida
Yumi Tsuchida
MSMaho Shiozawa
Maho Shiozawa
KHKazuyuki Handa
Kazuyuki Handa
HTHidekazu Takahashi
Hidekazu Takahashi
HNHiroki Nikawa
Hiroki Nikawa
Purpose: Handheld-type scanners are widely used in clinical practice. This study examined the accuracy of handheld-type scanners using plaster statues to assess their performance in facial recognition.Methods: Twelve 4-mm zirconia balls as measuring points were attached to the facial portions of three types of plaster statue. Six digital facial images of each plaster statue were obtained using one of the following five handheld-type scanners: Artec Eva, Artec Spider, Bellus 3D FaceApp, SNAP, and Vectra H1. Four-millimeter spherical objects were manually placed at the measurement points on the scanned data generated using computer-aided design software and coordinate positions were measured using a contact-type high-resolution three-dimensional measurement device. Consequently, the discrepancy between the distance measured using the contact-type device and that measured using the handheld-type scanner was calculated. The scanning time, processing time, and deviation of the distance between the measuring points were analyzed using two-way analysis of variance and t-test with Bonferroni correction.Results: The scanning and processing times ranged from 15.2 to 42.2 s and 20.7 to 234.2 s, respectively. Overall, 97% of all measured distances by Spider were within ±1.00% deviation; 79%, Vectra; 73%, Eva; 70%, Bellus; and 42%, SNAP.Conclusions: The performance of handheld-type scanners using plaster statues varied among the different scanners. The scanning time of Eva and the processing time of Bellus were significantly shorter than those of other scanners. Furthermore, Spider exhibited the best accuracy, followed by Eva, Vectra, Bellus, and SNAP.

1 January 2014 in International Journal of Refrigeration
Verified
Journal Article
Open access
UOUlrik Lund Olsen
Ulrik Lund Olsen
CBC.R.H. Bahl
C.R.H. Bahl
KEKurt Engelbrecht
Kurt Engelbrecht
KNKaspar Nielsen
Kaspar Nielsen
YTY. Tasaki
Y. Tasaki
HTHidekazu Takahashi
Hidekazu Takahashi

1 July 2019 in Journal of Prosthodontic Research
Verified
Journal Article
Closed access
TYToshiki Yamazaki
Toshiki Yamazaki
NMNatsuko Murakami
Natsuko Murakami
SSShizuka Suzuki
Shizuka Suzuki
KHKazuyuki Handa
Kazuyuki Handa
MYMasaru Yatabe
Masaru Yatabe
NWNoriyuki Wakabayashi
Noriyuki Wakabayashi
The purpose of this study was to determine the effect of block-out preparation, used to eliminate the undercut area, on the retentive force and stress distribution of resin clasps. A total of 72 polyester and polyamide resin clasps were fabricated on a premolar abutment crown following six block-out preparations. A combination of two types of vertical block-outs and three types of horizontal block-outs (on the missing side) was used on the abutment tooth. Each clasp was subjected to an in vitro removal test using a universal testing machine. The retentive force and traces of the clasp on the abutment tooth were recorded and analyzed with one-way analysis of variance and post hoc comparisons (α=0.05). Non-linear finite element analysis was performed to assess the stress distributions of the resin clasps. Resin clasps with a vertical block-out of 0.75mm undercut showed significantly higher retentive force than those with the 0.5mm undercut. Resin clasps with horizontal block-out showed significantly lower retentive force than those without horizontal block-out. There was no significant difference between the two thermoplastic resins. The maximum first principal stress of the resin clasp was concentrated under the shoulder of the clasp and strongly influenced by the width of horizontal block-out in the finite element analysis. This in vitro experiment suggested that a horizontal block-out is necessary even for a 0.5-mm undercut. The design of the resin clasp should be considered from two aspects: retentive force and deformation risk.