The article discusses the interaction of concrete structures with the soil, made on the basis of laboratory tests and numerical simulation. The objectives of the study were to obtain the strength characteristics at the contact of two different materials, to compare the obtained value of the strength reduction factor with the standard values, and also to determine the extent to which the interface must be taken into account when conducting numerical geotechnical calculations. The study was carried out using a direct shear test device, where the strength reduction factor was obtained, which characterizes the conditions of interaction between different materials at their contact. According to the results of numerical simulation, one can see how the consideration of the given characteristics of the material of the contact element affects the internal forces arising in the underground structure and its displacements. The test results showed that the particle diameter has a different effect on shear strength at the same level of normal stress. On the basis of the results obtained, conclusions were drawn on what needs to be paid more attention to when conducting laboratory tests, how strongly the consideration of contact elements with the correct set of properties affects the internal forces of the underground structure. Also, the remaining problems and factors not considered in this study determined the prospects for further research on the topic under consideration.
This research investigates the mechanical properties of soil-cement specimens ranging from ultrasmall to large values of shear strain at dynamic loading. The nonlinear behavior of soil cement exposed to dynamic loading in a wide range of changing shear strains was examined on the basis of two mechanical models. All soil-cement specimens were collected from under an existing building and modified with deep soil mixing (DSM.). Soil-cement samples were examined using low-amplitude oscillations in the resonant column and the dynamic triaxial compression method. Additionally, the stress–strain state for modified footings exposed to dynamic loading, and the approximation of soil stiffness and damping coefficient was analyzed. Dependencies on the basis of the resilient elastic models of Ramberg–Osgood and Hardin–Drnevich are proposed for application. Results reveal that the empirical graphs of the dependency soil stiffness–shear strain based on various methods exhibited the distinctive S-shape of decreased stiffness. The stiffness of the soil cement was reduced by 50% of the maximal value at shear strains of the 10−3 decimal order. The method presented in this study enables the drawing of stiffness change and damping–shear strain dependency where the range of shear strains changes from ultrasmall to large strains. The normalized modulus of shearing and the damping coefficient on shear strains for soil cement could be obtained under the proposed method. This method can be used for the preliminary calculations of structures on the footing modified by mathematical modelling or when field research data from site investigation are not available.
In process of designing foundations of circular form in plane, as well as bored piles of circular cross section, there is important to quantify the stress-strain state and the bearing capacity of the soils interacted with the foundations, as well as under the toe of piles. The article presents the formulation and solution of the problem of determining the initial critical load at the base of the circular foundation, which is also relevant for the design case of the soil under the toe of a circular bored pile. It is shown that the condition of limiting equilibrium arises both under the center of the loaded area and on the contour of the circular loading area, and primarily on the contour. A comparative estimate showed that the ratio of the initial critical load to the base soil of the circular foundation under the center of the site is 2 times greater than the corresponding load for the point at the edge of the site.
1 November 2019 in IOP Conference Series: Materials Science and Engineering
The article presents the formulation and analytical solution of the problem of determining the settlement and bearing capacity of an incompressible pile in a three-layer soil base, taking into account the elastic and elastic-visco-plastic properties of surrounding and underlying soils. It is shown that the force applied to the pile head is distributed and redistributed between the lateral surface of the shell of pile and its tip in time, and that the stress under the tip of the pile increases in time and may approach the critical load. Formulas for determining the settlement and bearing capacity of the pile in time are obtained depending on the physical and mechanical properties of the surrounding and underlying soils, the length and diameter of the pile by the analytical method.