Ursula Reiter

Dr. Ursula Reiter


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in British Journal of Radiology
Verified
Journal Article
Open access
URUrsula Reiter
Ursula Reiter
GRGert Reiter
Gert Reiter
MFMichael Fuchsjäger
Michael Fuchsjäger
Pulmonary hypertension (PH) is a life-threatening, multifactorial pathophysiological haemodynamic condition, diagnosed when the mean pulmonary arterial pressure equals or exceeds 25 mmHg at rest du...

27 April 2016 in European Radiology
Verified
Journal Article
Open access
PDF file
URUrsula Reiter
Ursula Reiter
GRGert Reiter
Gert Reiter
GKGabor Kovacs
Gabor Kovacs
GAGabriel Adelsmayr
Gabriel Adelsmayr
AGAndreas Greiser
Andreas Greiser
MFMichael Fuchsjäger
Michael Fuchsjäger
Objectives To analyze alterations in left ventricular (LV) myocardial T1 times in patients with pulmonary hypertension (PH) and to investigate their associations with ventricular function, mass, geometry and hemodynamics. Methods Fifty-eight patients with suspected PH underwent right heart catheterization (RHC) and 3T cardiac magnetic resonance imaging. Ventricular function, geometry and mass were derived from cine real-time short-axis images. Myocardial T1 maps were acquired by a prototype modified Look-Locker inversion-recovery sequence in short-axis orientations. LV global, segmental and ventricular insertion point (VIP) T1 times were evaluated manually and corrected for blood T1. Results Septal, lateral, global and VIP T1 times were significantly higher in PH than in non-PH subjects (septal, 1249 ± 58 ms vs. 1186 ± 33 ms, p < 0.0001; lateral, 1190 ± 45 ms vs. 1150 ± 33 ms, p = 0.0003; global, 1220 ± 52 ms vs. 1171 ± 29 ms, p < 0.0001; VIP, 1298 ± 78 ms vs. 1193 ± 31 ms, p < 0.0001). In PH, LV eccentricity index was the strongest linear predictor of VIP T1 (r = 0.72). Septal, lateral and global T1 showed strong correlations with VIP T1 (r = 0.81, r = 0.59 and r = 0.75, respectively). Conclusions In patients with PH, T1 times in VIPs and in the entire LV myocardium are elevated. LV eccentricity strongly correlates with VIP T1 time, which in turn is strongly associated with T1 time changes in the entire LV myocardium. Key Points • Native T1 mapping detects left ventricular myocardial alterations in pulmonary hypertension • In pulmonary hypertension, native T1 times at ventricular insertion points are increased • These T1 times correlate strongly with left ventricular eccentricity • In pulmonary hypertension, global and segmental myocardial T1 times are increased • Global, segmental and ventricular insertion point T1 times are strongly correlated

24 September 2020 in European Radiology
Verified
Journal Article
Open access
PDF file
URUrsula Reiter
Ursula Reiter
GKGabor Kovacs
Gabor Kovacs
CRClemens Reiter
Clemens Reiter
CKCorina Kräuter
Corina Kräuter
VNVolha Nizhnikava
Volha Nizhnikava
GRGert Reiter
Gert Reiter
Objectives: Longitudinal hemodynamic follow-up is important in the management of pulmonary hypertension (PH). This study aimed to evaluate the potential of MR 4-dimensional (4D) flow imaging to predict changes in the mean pulmonary arterial pressure (mPAP) during serial investigations. Methods: Forty-four adult patients with PH or at risk of developing PH repeatedly underwent routine right heart catheterization (RHC) and near-term MR 4D flow imaging of the main pulmonary artery. The duration of vortical blood flow along the main pulmonary artery was evaluated from MR 4D velocity fields using prototype software and converted to an MR 4D flow imaging-based mPAP estimate (mPAPMR) by a previously established model. The relationship of differences between RHC-derived baseline and follow-up mPAP values (ΔmPAP) to corresponding differences in mPAPMR (ΔmPAPMR) was analyzed by means of regression and Bland-Altman analysis; the diagnostic performance of ΔmPAPMR in predicting mPAP increases or decreases was investigated by ROC analysis. Results: Areas under the curve for the prediction of mPAP increases and decreases were 0.92 and 0.93, respectively. With the natural cutoff ΔmPAPMR = 0 mmHg, mPAP increases (decreases) were predicted with an accuracy, sensitivity, and specificity of 91% (91%), 85% (89%), and 94% (92%), respectively. For patients in whom 4D flow allowed a point estimate of mPAP (mPAP > 16 mmHg), ΔmPAPMR correlated strongly with ΔmPAP (r = 0.91) and estimated ΔmPAP bias-free with a standard deviation of 5.1 mmHg. Conclusions: MR 4D flow imaging allows accurate non-invasive prediction and quantification of mPAP changes in adult patients with PH or at risk of developing PH. Trial registration: ClinicalTrials.gov identifier: NCT00575692 and NCT01725763 Key Points: • MR 4D flow imaging allows accurate non-invasive prediction of mean pulmonary arterial pressure increases and decreases in adult patients with or at risk of developing pulmonary hypertension. • In adult patients with mean pulmonary arterial pressure > 16 mmHg, MR 4D flow imaging allows estimation of longitudinal mean pulmonary arterial pressure changes without bias with a standard deviation of 5.1 mmHg.

1 December 2018 in European Journal of Radiology
Verified
Journal Article
Open access
URUrsula Reiter
Ursula Reiter
CRClemens Reiter
Clemens Reiter
CKCorina Kräuter
Corina Kräuter
MFMichael Fuchsjäger
Michael Fuchsjäger
GRGert Reiter
Gert Reiter
Non-invasive identification and differentiation of myocardial diseases represents the primary objectives of cardiac magnetic resonance (CMR) longitudinal relaxation time (T1) and extracellular volume (ECV) mapping. Given the fact that myocardial T1 and ECV values overlap throughout and within left ventricular phenotypes, a central issue to be addressed is whether and to what extent myocardial T1 and ECV mapping provides additional or superior diagnostic information to standard CMR imaging, and whether native T1 mapping could be employed as a non-contrast alternative to late gadolinium enhancement (LE) imaging. The present review aims to summarize physiological and pathophysiological alterations in native T1 and ECV values and summarized myocardial T1 and ECV alterations associated with cardiac diseases to support the translation of research findings into routine CMR imaging.

1 December 2018 in European Journal of Radiology
Verified
Journal Article
Open access
GRGert Reiter
Gert Reiter
CRClemens Reiter
Clemens Reiter
CKCorina Kräuter
Corina Kräuter
MFMichael Fuchsjäger
Michael Fuchsjäger
URUrsula Reiter
Ursula Reiter
While an enormous number of studies have documented pathological alterations of the myocardial native longitudinal relaxation time (T1) and the fraction of the extracellular myocardial volume (ECV), it has also become clear that continuously evolving T1 mapping sequence, acquisition and evaluation techniques have a substantial impact on quantitative results, making the translation of reported findings into routine clinical use particularly challenging. To provide a basis for the discussion of pathological myocardial T1 and ECV alterations, the present review aims to summarize the methodological aspects of myocardial T1 mapping along with technical and physiological factors influencing results and normal ranges of myocardial native T1 and ECV reported across studies.

1 January 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
URUrsula Reiter
Ursula Reiter
GRGert Reiter
Gert Reiter
MMMartin Manninger
Martin Manninger
GAGabriel Adelsmayr
Gabriel Adelsmayr
JSJulia Schipke
Julia Schipke
MFMichael Fuchsjäger
Michael Fuchsjäger
The hypertensive deoxy-corticosterone acetate (DOCA)-salt-treated pig (hereafter, DOCA pig) was recently introduced as large animal model for early-stage heart failure with preserved ejection fraction (HFpEF). The aim of the present study was to evaluate cardiovascular magnetic resonance (CMR) of DOCA pigs and weight-matched control pigs to characterize ventricular, atrial and myocardial structure and function of this phenotype model. Five anesthetized DOCA and seven control pigs underwent 3 T CMR at rest and during dobutamine stress. Left ventricular/atrial (LV/LA) function and myocardial mass (LVMM), strains and torsion were evaluated from (tagged) cine imaging. 4D phase-contrast measurements were used to assess blood flow and peak velocities, including transmitral early-diastolic (E) and myocardial tissue (E’) velocities and coronary sinus blood flow. Myocardial perfusion reserve was estimated from stress-to-rest time-averaged coronary sinus flow. Global native myocardial T1 times were derived from prototype modified Look-Locker inversion-recovery (MOLLI) short-axis T1 maps. After in-vivo measurements, transmural biopsies were collected for stereological evaluation including the volume fractions of interstitium (VV(int/LV)) and collagen (VV(coll/LV)). Rest, stress, and stress-to-rest differences of cardiac and myocardial parameters in DOCA and control animals were compared by t-test. In DOCA pigs LVMM (p < 0.001) and LV wall-thickness (end-systole/end-diastole, p = 0.003/p = 0.007) were elevated. During stress, increase of LV ejection-fraction and decrease of end-systolic volume accounted for normal contractility reserves in DOCA and control pigs. Rest-to-stress differences of cardiac index (p = 0.040) and end-diastolic volume (p = 0.042) were documented. Maximal (p = 0.042) and minimal (p = 0.012) LA volumes in DOCA pigs were elevated at rest; total LA ejection-fraction decreased during stress (p = 0.006). E’ was lower in DOCA pigs, corresponding to higher E/E’ at rest (p = 0.013) and stress (p = 0.026). Myocardial perfusion reserve was reduced in DOCA pigs (p = 0.031). T1-times and VV(int/LV) did not differ between groups, whereas VV(coll/LV) levels were higher in DOCA pigs (p = 0.044). LA enlargement, E’ and E/E’ were the markers that showed the most pronounced differences between DOCA and control pigs at rest. Inadequate increase of myocardial perfusion reserve during stress might represent a metrics for early-stage HFpEF. Myocardial T1 mapping could not detect elevated levels of myocardial collagen in this model. The study was approved by the local Bioethics Committee of Vienna, Austria (BMWF-66.010/0091-II/3b/2013).