Nithyaprakash Rajavel

Dr. Nithyaprakash Rajavel

Kongu Engineering College, Erode, Tamil Nādu, India
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2020 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
Shankar SubramaniamShankar Subramaniam
Shankar Subramaniam
NRNithyaprakash Rajavel
Nithyaprakash Rajavel
BSB. R Santhosh
B. R Santhosh
Mohammad UddinMohammad Uddin
Mohammad Uddin
APAlokesh Pramanik
Alokesh Pramanik
Finite element (FE) simulation plays a major role in computing stress and predicting the failure of biomedical components. Normally in past, researchers focused on developing a global computational model from the scanned data of patients to analyze the stresses and deformations. To compute the wear of the hip prosthesis, mostly the global model (GM) is used to predict the expected life for million cycles using nodal updating technique which leads to high computational effort and time. The proposed work utilizes a submodeling finite element technique to analyze the contact pressure and wear of biomaterials for three different combinations in hip prosthesis including metal, ceramic and polycrystalline diamond materials. Initially the global model boundary and loading conditions are transferred to the submodel. The mesh is refined further using finer mesh and then the results are computed which consumes lesser time. The contact stress as well as the linear wear of biomaterials is found to be quite high for the local model (LM) when compared with the global model. However, no changes in volumetric wear of these biomaterials are observed when compared with previous experimental results. The computational time as well as accuracy in estimating the contact stress and the wear of bearings is improved effectively. Among local model with different element sizes, 0.75 mm element size of local model showed improved results in estimating the contact stress and linear wear of bearing.

2 November 2017 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
NRNithyaprakash Rajavel
Nithyaprakash Rajavel
Shankar SubramaniamShankar Subramaniam
Shankar Subramaniam
Mohammad UddinMohammad Uddin
Mohammad Uddin

19 March 2014 in Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
Verified
Journal Article
Closed access
Shankar SubramaniamShankar Subramaniam
Shankar Subramaniam
NRNithyaprakash Rajavel
Nithyaprakash Rajavel
Wear is one of the important tribological parameter that increases the revision rate of artificial hip implantation. Silicon nitride (Si3N4) is one of the promising ceramic materials with low wear rate and has been implanted in patients for the past 3 years. The objective of this paper is to analyse the effect of radial clearance over the contact pressure and wear of Si3N4 bearing couple, i.e. acetabulam cup and femoral head, using finite element concepts. The 3D force values for normal walking cycle of hip joint are used to predict the contact pressure and 3D rotation angles are used to calculate the sliding distance in determining the wear of bearing couple. The finite element results are validated initially with the previous experimental results. Then the analysis is extended to various radial clearance values. The increase in radial clearance values resulted in increase in linear wear but there is not much change in the volumetric wear.

28 April 2014 in Tribology Transactions
Verified
Journal Article
Closed access
Shankar SubramaniamShankar Subramaniam
Shankar Subramaniam
NRNithyaprakash Rajavel
Nithyaprakash Rajavel
Wear of the bearing surface increases the revision rate of artificial hip replacements and is influenced by the radial clearances between the acetabulum cup and the femoral head. The objective of this article is to determine the effect of various radial clearance values over the contact pressure and wear of the hard-on-hard—that is, polycrystalline diamond (PCD)—hip prostheses using finite element concepts for normal walking conditions. The wear of the hip bearing surface is determined by considering the contact pressures obtained from the hip gait instants of normal walking activity and sliding distance determined from the three-dimensional hip gait motions. The radial clearance value of 0.05 mm showed less volumetric wear rate when compared with other radial clearance values. Overall, it is recommended that the low radial clearance between the contacting pair is suitable for PCD-on-PCD hip prostheses.

1 November 2020 in Tribology International
Verified
Journal Article
Closed access
Shankar SubramaniamShankar Subramaniam
Shankar Subramaniam
NRNithyaprakash Rajavel
Nithyaprakash Rajavel
BSB.R. Santhosh
B.R. Santhosh
AGAli Kaya Gur
Ali Kaya Gur
APAlokesh Pramanik
Alokesh Pramanik

9 May 2016 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
PDF file
Shankar SubramaniamShankar Subramaniam
Shankar Subramaniam
NRNithyaprakash Rajavel
Nithyaprakash Rajavel