Phillip Hsin Kuo

Prof. Dr. Phillip Hsin Kuo

1. Department of Medical Imaging, University of Arizona, Tucson, AZ 85724, USA
+2

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2013 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LCLiu Qi Chen
Liu Qi Chen
CHChristine M. Howison
Christine M. Howison
JJJustin J. Jeffery
Justin J. Jeffery
IRIan F. Robey
Ian F. Robey
Phillip Hsin KuoPhillip Hsin Kuo
Phillip Hsin Kuo
MPMark Pagel
Mark Pagel
Purpose: A practical, noninvasive method is needed to measure the extracellular pH (pHe) within in vivo tumors to longitudinally monitor tumor acidosis. We have optimized a biomedical imaging method, termed acidoCEST MRI, to provide noninvasive assessments of tumor pHe in preclinical models of mammary carcinoma.Methods: A CEST‐FISP MRI method was optimized to detect the chemical exchange saturation transfer (CEST) of two amide protons of a clinically approved CT contrast agent, iopromide. The ratio of the two CEST effects was used to measure pH. Routes of administration of iopromide were evaluated to ensure sufficient delivery of the agent to the tumor. The optimized acidoCEST MRI method was then used to evaluate the change in tumor pHe following alkalinizing bicarbonate treatment.Results: The acidoCEST MRI protocol measured pH between 6.2 and 7.2 pH units. Greater delivery of iopromide was shown to improve the precision of the measurement of tumor pHe, but the agent did not influence the tumor pHe. AcidoCEST MRI was used to longitudinally monitor the effect of bicarbonate treatment on the pHe of tumors and bladders.Conclusion: This study demonstrates that an optimized acidoCEST MRI method is a practical, noninvasive method for assessing changes in tumor acidosis. Magn Reson Med 72:1408–1417, 2014.

1 September 2018 in Tomography
Verified
Journal Article
Open access
Phillip Hsin KuoPhillip Hsin Kuo
Phillip Hsin Kuo
CSCarol Stuehm
Carol Stuehm
SSScott Squire
Scott Squire
KJKevin Johnson
Kevin Johnson
The recent report of the existence of meningeal lymphatic vessels (MLVs) in human and nonhuman primates used both histology and magnetic resonance imaging (MRI). Many questions about the physiology and function of these lymphatic vessels remain unanswered. Through the combination of appropriately positioned saturation bands and time-of-flight angiography sequences, MRI can resolve direction of flow within vessels without the use of exogenous contrast agent. Six healthy volunteers underwent high-resolution MRI of the MLVs running alongside the superior sagittal sinus to determine the direction of the lymphatic flow. In all subjects, the lymphatic flow was posterior to anterior, countercurrent to the direction of venous flow in the superior sagittal sinus and alongside the superior sagittal sinus. This flow strongly supports that a large proportion of the CNS lymphatic flow in humans is directed to the cribriform plate. The countercurrent direction of flow in the MLVs relative to venous flow in the superior sagittal sinus has implications for modeling flow of fluid and solutes across the various compartments of the CNS. A hypothetical compartmental model incorporating countercurrent flow is presented here.

27 January 2022 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
Phillip Hsin KuoPhillip Hsin Kuo
Phillip Hsin Kuo
TBTaylor Benson
Taylor Benson
RMRichard Messmann
Richard Messmann
MGMichael Groaning
Michael Groaning

25 May 2023 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
Phillip Hsin KuoPhillip Hsin Kuo
Phillip Hsin Kuo
DYDon C. Yoo
Don C. Yoo
RARyan Avery
Ryan Avery
MSMarc Seltzer
Marc Seltzer
JCJeremie Calais
Jeremie Calais
AKAyse T. Kendi
Ayse T. Kendi
[ 68Ga]Ga-PSMA-11 ( 68Ga-PSMA-11) is used to identify prostate-specific membrane antigen (PSMA)–positive tumors on PET scans. In the VISION study, 68Ga-PSMA-11 was used to determine the eligibility of patients with metastatic castration-resistant prostate cancer for treatment with [177Lu]Lu-PSMA-617 (177Lu-PSMA-617), based on predefined read criteria. This substudy aimed to investigate the interreader variability and intrareader reproducibility of visual assessments of 68Ga-PSMA-11 PET/CT scans using the VISION read criteria and evaluate the agreement between read results for this and the VISION study. Methods: In VISION, 68Ga-PSMA-11 PET/CT scans were centrally read as inclusion cases if they had at least 1 PSMA-positive lesion and no PSMA-negative lesions that fulfilled the exclusion criteria. In this substudy, 125 PET/CT scans (75 inclusion and 50 exclusion cases) were randomly selected from VISION and retrospectively assessed by 3 independent central readers. A random subset of 20 cases (12 inclusion and 8 exclusion cases) was recoded for assessment of intrareader reproducibility. Classification of cases as inclusion or exclusion cases was based on the VISION read criteria. Overall interreader variability was assessed by Fleiss κ-statistics, and pairwise variability and intrareader reproducibility were assessed by Cohen κ-statistics. Results: For interreader variability, the readers agreed on 77% of cases (overall average agreement rate, 0.85; Fleiss κ, 0.60 [95% CI, 0.50–0.70]). The pairwise agreement rate was 0.82, 0.88, and 0.84, and the corresponding Cohen κ was 0.54 (95% CI, 0.38–0.71), 0.67 (95% CI, 0.52–0.83), and 0.59 (95% CI, 0.43–0.75), respectively. For intrareader reproducibility, the agreement rate was 0.90, 0.90, and 0.95, and the corresponding Cohen κ was 0.78 (95% CI, 0.49–0.99), 0.76 (95% CI, 0.46–0.99), and 0.89 (95% CI, 0.67–0.99), respectively. The number of actual VISION inclusion cases out of the total number of cases scored as inclusion in this substudy was 71 of 93 (agreement rate, 0.76; 95% CI, 0.66–0.85) for reader 1, 70 of 88 (0.80; 0.70–0.87) for reader 2, and 73 of 96 (0.76; 0.66–0.84) for reader 3. All readers agreed on 66 of 75 VISION inclusion cases. Conclusion: Moderate-to-substantial interreader agreement and substantial-to-almost perfect intrareader reproducibility for 68Ga-PSMA-11 PET/CT scan assessment using the VISION read criteria were observed. The read rules applied in VISION can be readily learned and demonstrate good reproducibility. Visual Abstract

18 December 2021 in Tomography
Verified
Journal Article
Open access
PDF file
MNMatthew Neill
Matthew Neill
Julia FisherJulia Fisher
Julia Fisher
CBChristine Brand
Christine Brand
HLHong Lei
Hong Lei
SSScott J. Sherman
Scott J. Sherman
Phillip Hsin KuoPhillip Hsin Kuo
Phillip Hsin Kuo
Evaluation of Parkinsonian Syndromes (PS) with Ioflupane iodine-123 dopamine transporter single photon emission computed tomography (DaT-SPECT), in conjunction with history and clinical examination, aids in diagnosis. FDA-approved, semi-quantitative software, DaTQUANTTM (GE Healthcare, Chicago, IL, USA) is available to assist in interpretation. This study aims to evaluate the optimal variables and thresholds of DaTQUANT to yield the optimal diagnostic accuracy. It is a retrospective review with three different patient populations. DaT-SPECT images from all three study groups were evaluated using DaTQUANTTM software, and both single and multi-variable logistic regression were used to model PS status. The optimal models were chosen via accuracy, sensitivity, and specificity, then evaluated on the other study groups. Among single variable models, the posterior putamen yielded the highest accuracy (84% to 95%), while balancing sensitivity and specificity. Multi-variable models did not substantially improve the accuracy. When the optimal single variable models for each group were used to evaluate the remaining two groups, comparable results were achieved. In typical utilization of DaT-SPECT for differentiation between nigrostriatal degenerative disease (NSDD) and non-NSDD, the posterior putamen was the single variable that yielded the highest accuracy across three different patient populations. The posterior putamen’s recommended thresholds for DaTQUANT are SBR ≤ 1.0, z-score of ≤−1.8 and percent deviation ≤ −0.34.

11 February 2013 in Journal of Nuclear Medicine Technology
Verified
Journal Article
Open access
PDF file
Phillip Hsin KuoPhillip Hsin Kuo
Phillip Hsin Kuo
RARyan Avery
Ryan Avery
EKElizabeth Krupinski
Elizabeth Krupinski
HLHong Lei
Hong Lei
ABAdam Bauer
Adam Bauer
GZGeorge Zubal
George Zubal
A fully automated objective striatal analysis (OSA) program that quantitates dopamine transporter uptake in subjects with suspected Parkinson’s disease was applied to images from clinical 123I-ioflupane studies. The striatal binding ratios or alternatively the specific binding ratio (SBR) of the lowest putamen uptake was computed, and receiver-operating-characteristic (ROC) analysis was applied to 94 subjects to determine the best discriminator using this quantitative method. Methods: Ninety-four 123I-ioflupane SPECT scans were analyzed from patients referred to our clinical imaging department and were reconstructed using the manufacturer-supplied reconstruction and filtering parameters for the radiotracer. Three trained readers conducted independent visual interpretations and reported each case as either normal or showing dopaminergic deficit (abnormal). The same images were analyzed using the OSA software, which locates the striatal and occipital structures and places regions of interest on the caudate and putamen. Additionally, the OSA places a region of interest on the occipital region that is used to calculate the background-subtracted SBR. The lower SBR of the 2 putamen regions was taken as the quantitative report. The 33 normal (bilateral comma-shaped striata) and 61 abnormal (unilateral or bilateral dopaminergic deficit) studies were analyzed to generate ROC curves. Results: Twenty-nine of the scans were interpreted as normal and 59 as abnormal by all 3 readers. For 12 scans, the 3 readers did not unanimously agree in their interpretations (discordant). The ROC analysis, which used the visual-majority-consensus interpretation from the readers as the gold standard, yielded an area under the curve of 0.958 when using 1.08 as the threshold SBR for the lowest putamen. The sensitivity and specificity of the automated quantitative analysis were 95% and 89%, respectively. Conclusion: The OSA program delivers SBR quantitative values that have a high sensitivity and specificity, compared with visual interpretations by trained nuclear medicine readers. Such a program could be a helpful aid for readers not yet experienced with 123I-ioflupane SPECT images and if further adapted and validated may be useful to assess disease progression during pharmaceutical testing of therapies.