Hao Shen

Dr. Hao Shen

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
JWJiaxing Wang
Jiaxing Wang
JLJinhua Li
Jinhua Li
SQShi Qian
Shi Qian
GGGeyong Guo
Geyong Guo
QWQiaojie Wang
Qiaojie Wang
PCPaul Chu
Paul Chu

7 September 2016 in Scientific Reports
Verified
Journal Article
Open access
JWJiaxing Wang
Jiaxing Wang
JLJinhua Li
Jinhua Li
GGGeyong Guo
Geyong Guo
QWQiaojie Wang
Qiaojie Wang
JTJin Tang
Jin Tang
XZXianlong Zhang
Xianlong Zhang
Titanium implants are widely used clinically, but postoperative implant infection remains a potential severe complication. The purpose of this study was to investigate the antibacterial activity of nano-silver(Ag)-functionalized Ti surfaces against epidemic Staphylococcus from the perspective of the regulation of biofilm-related genes and based on a bacteria-cell co-culture study. To achieve this goal, two representative epidemic Staphylococcus strains, Staphylococcus epidermidis (S. epidermidis, RP62A) and Staphylococcus aureus (S. aureus, USA 300), were used, and it was found that an Ag-nanoparticle-modified Ti surface could regulate the expression levels of biofilm-related genes (icaA and icaR for S. epidermidis; fnbA and fnbB for S. aureus) to inhibit bacterial adhesion and biofilm formation. Moreover, a novel bacteria-fibroblast co-culture study revealed that the incorporation of Ag nanoparticles on such a surface can help mammalian cells to survive, adhere and spread more successfully than Staphylococcus. Therefore, the modified surface was demonstrated to possess a good anti-infective capability against both sessile bacteria and planktonic bacteria through synergy between the effects of Ag nanoparticles and ion release. This work provides new insight into the antimicrobial action and mechanism of Ag-nanoparticle-functionalized Ti surfaces with bacteria-killing and cell-assisting capabilities and paves the way towards better satisfying the clinical needs.

9 April 2022 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
HXHaixia Xu
Haixia Xu
FZFeiyang Zhang
Feiyang Zhang
MWMenglong Wang
Menglong Wang
HLHe Lv
He Lv
Deng-Guang YuDeng-Guang Yu
Deng-Guang Yu
HSHao Shen
Hao Shen

9 September 2021 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
QXQize Xuan
Qize Xuan
FJFeng Jiang
Feng Jiang
HDHao Dong
Hao Dong
WZWenxue Zhang
Wenxue Zhang
FZFeiyang Zhang
Feiyang Zhang
PWPing Wang
Ping Wang

1 April 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
CYChuang Yang
Chuang Yang
JLJinhua Li
Jinhua Li
CZChongzun Zhu
Chongzun Zhu
QZQixuan Zhang
Qixuan Zhang
JYJinlong Yu
Jinlong Yu
HSHao Shen
Hao Shen

1 March 2015 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
PDF file
HSHao Shen
Hao Shen
JTJin Tang
Jin Tang
QWQiaojie Wang
Qiaojie Wang
YJYao Jiang
Yao Jiang
XZXianlong Zhang
Xianlong Zhang
Prosthetic joint infection (PJI) is a rare but refractory complication of arthroplasty. Accurate identification of pathogens is a key step for successful treatment of PJI, which remains a challenge for clinicians and laboratory workers. We designed a combined culture method with sonication of implants and incubation in a BD Bactec system to improve the effectiveness of pathogen diagnosis in PJI. The aims of this study were to investigate the diagnostic accuracy of sonicate fluid cultures in the BD Bactec system and to compare the results with those of synovial fluid cultures in the BD Bactec system. The prosthetic components removed were sonicated in Ringer's solution, and then sonicate fluid was incubated in Bactec bottles for 5 days. Synovial fluid was incubated in Bactec bottles for 5 days as a control. Synovial fluid cultures with Bactec bottles and sonicate fluid cultures with Bactec bottles showed sensitivities of 64% and 88%, respectively ( P = 0.009), with specificities of 98% and 87% ( P = 0.032), respectively. Sonicate fluid cultures with Bactec bottles were more sensitive than synovial fluid cultures with Bactec bottles regardless of whether antimicrobial agents were used within 14 days before surgery (81% versus 52%; P = 0.031) or not (93% versus 72%; P = 0.031). Sonication of explanted prostheses followed by incubation of the resulting sonicate fluid in Bactec bottles detected many more pathogens than did synovial fluid cultures with Bactec bottles. This method is also effective in cases with antibiotic treatment before surgery.