Background: Premature failures of wheelchairs in less-resourced environments (LREs) may be because of shortcomings in product regulation and quality standards. The standards published by the International Organization for Standardization (ISO) specify wheelchair tests for durability, safety and performance, but their applicability to products used in the rugged conditions of LREs is unclear. Because of this, wheelchair-related guidelines published by the World Health Organization recommended developing more rigorous durability tests for wheelchairs.Objectives: This study was performed to identify the additional tests needed for LREs.Methods: First, a literature review of the development of ISO test standards, wheelchair standards testing studies and wheelchair evaluations in LREs was performed. Second, expert advice from members of the Standards Working Group of the International Society of Wheelchair Professionals (ISWP) was compiled and reviewed.Results: A total of 35 articles were included in the literature review. Participation from LREs was not observed in the ISO standards development. As per wheelchair testing study evidence, wheelchair models delivered in LREs did not meet the minimum standards requirement. Multiple part failures and repairs were observed with reviewed field evaluation studies. ISWP experts noted that several testing factors responsible for premature failures with wheelchair parts are not included in the standards and accordingly provided advice for additional test development.Conclusion: The study findings indicate the need to develop a wide range of tests, with specific tests for measuring corrosion resistance of the entire wheelchair, rolling resistance of castors and rear wheels, and durability of whole wheelchair and castor assemblies.

18 October 2022 in JMIR Aging
Verified
Journal Article
Open access
ABAlyssa Boccardi
Alyssa Boccardi
FWFangzheng Wu
Fangzheng Wu
JPJonathan Pearlman
Jonathan Pearlman
AMAnand Mhatre
Anand Mhatre
Background: Wheelchair part failures have doubled over the past decade. Preventative wheelchair maintenance reduces wheelchair failures and prevents user consequences. We are developing a smartphone app called WheelTrak, which alerts users when maintenance is required, to encourage maintenance practices and compliance. Objective: This mixed methods study aimed to develop a wheelchair maintenance app using broad stakeholder advice and investigate older adults’ interaction experience with the app and their perceived barriers to and facilitators of maintenance. Methods: Interviews were conducted with stakeholders, including mobility device users, to generate needs statements and app specifications. The app was designed in 2 stages. Stage 1 involved the development of the app according to the specifications and evaluation of the app interface by lead users. Stage 2 included the revision of the app screens and manual functionality testing. Usability testing and semistructured interviews were conducted with older wheelchair and scooter users. The System Usability Scale was used to measure app usability. Results: Interviews with power and manual wheelchair users (37/57, 65%), wheelchair service providers (15/57, 26%), manufacturers (2/57, 4%), seating and mobility researchers (1/57, 2%), and insurance plan providers (2/57, 4%) informed the needs and specifications of the app technology. The 2-stage development process delivered a fully functional app that met the design specifications. In total, 12 older adults (mean age 74.2, SD 9.1 years; n=10, 83% women; and n=2, 17% men) participated in the usability testing study. Of the 12 participants, 9 (75%) agreed to use WheelTrak for preventative maintenance. WheelTrak scored an average System Usability Scale score of 60.25 (SD 16). Four overarching themes were identified: WheelTrak app improvements, barriers to maintenance, consequences related to mobility device failure, and smart technology use and acceptance. Older adults preferred the simplicity, readability, personalization, and availability of educational resources in the app. Barriers to maintenance pertained to health issues and lack of maintenance knowledge among older adults. Facilitators of maintenance included notification for maintenance, app connectivity with the service provider, reporting of device failure, and the presence of a caregiver for maintenance. Conclusions: This study highlighted age-friendly design improvements to the app, making it easy to be used and adopted by older wheelchair users. The WheelTrak app has close to average system usability. Additional usability testing will be conducted following app revision in the future.

19 August 2021 in Spinal Cord
Verified
Journal Article
Open access
PDF file
AMAnand Mhatre
Anand Mhatre
JPJon Pearlman
Jon Pearlman
MSMark Schmeler
Mark Schmeler
BKBenjamin Krider
Benjamin Krider
JFJohn Fried
John Fried
Study design: Secondary data analysis of wheelchair failures and service repair logs from a network of wheelchair suppliers. Objective: To determine the frequency of wheelchair caster failures and service repairs across wheelchair manufacturers and models and investigate the relationships between them. Setting: Wheelchair caster failures and service repairs occurred in the community. Methods: Reported caster failure types were classified based on the risk they pose for user injuries and wheelchair damage. Caster failures experienced by users of tilt-in-space and ultralightweight manual wheelchair models and Group 2, 3 and 4 power wheelchair models between January 2017 and October 2019 were analyzed using Chi-Square tests for independence. Correlational analysis of failures and service repairs was performed. Results: A total of 6470 failures and 151 service repairs reported across four manufacturers and five models were analyzed. Failure types were significantly associated with manufacturers and models, respectively. Users of tilt-in-space wheelchairs, who require greater seating support, experienced twice the proportion of high-risk caster failures than the ultralightweight manual wheelchair users. Similarly, Group 3 and 4 power wheelchair users, who have complex rehabilitation needs, experienced 15-36% more high-risk failures than Group 2 users. Service repairs negatively correlated with high-risk manual wheelchair caster failures. Conclusions: Wheelchair users who have greater seating and complex rehabilitation needs are at a higher risk for sustaining injuries and secondary health complications due to frequent caster failures. The study findings call for significant reforms in product quality and preventative maintenance practices that can reduce wheelchair failures and user consequences.

12 September 2022 in Disability and Rehabilitation: Assistive Technology
Verified
Journal Article
Closed access
JRJeffrey J. Ruffing
Jeffrey J. Ruffing
MSMark R. Schmeler
Mark R. Schmeler
RSRichard M. Schein
Richard M. Schein
AMAnand Mhatre
Anand Mhatre
It is documented that wheelchair failures occur frequently, repair times are lengthy, and users often experience adverse consequences. This study aims to gather evidence on efficiency of current wh...

2 November 2022 in Societies
Verified
Journal Article
Open access
PDF file
ABAlyssa Boccardi
Alyssa Boccardi
KSKimberly A. Szucs
Kimberly A. Szucs
IEIkenna Ebuenyi
Ikenna Ebuenyi
AMAnand Mhatre
Anand Mhatre
Makerspaces can engage people with disabilities in the design and development of assistive technology (AT) that can enhance their capabilities to perform new activities and function. However, the adoption of makerspaces in the environments and institutions serving people with disabilities remains challenging. The authors modeled a makerspace training program, an environmental intervention, based on the capability approach framework. This mixed methods study investigates the feasibility of an 8-week program to train adults (n = 5) with intellectual and developmental disabilities (IDD) and staff members (n = 5) at a community services center. Study outcomes were measured using knowledge tests, surveys, QUEST 2.0 and interviews. Results indicate a significant increase in staff’s knowledge (p = 0.035) and familiarity with program topics (p < 0.05). Participants with IDD were highly satisfied with the ease of use, weight and effectiveness of the AT devices they created. Five themes emerged from the thematic analysis of interviews: (1) inclusive environment, (2) freedom and improved Capability for building technology for self or client, (3) multidisciplinary collaboration, (4) interactive program elements, (5) makerspace challenges. Overall, the makerspace training program is a valuable program that empowers people with disabilities and ensures the realization of their right of autonomy to create their own AT.

10 January 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AMAnand Mhatre
Anand Mhatre
NRNorman Reese
Norman Reese
JPJon Pearlman
Jon Pearlman
Wheelchair castors fail frequently causing physical, social and economic consequences for wheelchair users. These failures occur in spite of established wheelchair test methods and regulations, suggesting that the existing tests may not be sufficient to screen poorly designed castors. An expert stakeholder group, convened by the International Society of Wheelchair Professionals (ISWP), noted castor failures as a high priority and recommended that a new castor testing system should be developed. In a previous study, the effect of shock exposure on castor durability was studied. The current paper extends the previous work and focuses on the development of a castor testing protocol based on shock, corrosion and abrasion exposure data collected in the community. The testing protocol was applied to 8 different castor models tested under four conditions: shock, corrosion + shock, abrasion + shock and abrasion + corrosion + shock. For each model, a total of n = 8 samples were evaluated across the four conditions. Results demonstrate that corrosion and abrasion reduced castor durability between 13% to 100% depending on the model. Importantly, the inclusion of corrosion and abrasion resulted in changes in the failure modes for 75% of the tested models and two-thirds of the altered failure modes are associated with increased risk of injury for wheelchair users. These results suggest that corrosion and abrasion present in the community reduce castor durability, thus supporting their inclusion in the castor testing protocol and potentially other wheelchair standards.