Chiung-Cheng  Chuang

Prof. Chiung-Cheng Chuang

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KLKuan-Ting Lee
Kuan-Ting Lee
MDMin-Jhen Dai
Min-Jhen Dai
CCChiung-Cheng Chuang
Chiung-Cheng Chuang
As implantable devices become more sophisticated and their extended functionalities impact their energy requirements, they not only rely on charging for the extra energy but also become ever more sensitive to battery deep discharge or overcharge. Accurate state-of-charge (SOC) estimation plays a fundamental role in ensuring the operation safety of implantable medical devices. Temperature variation can impact the battery model parameters and directly affect the accuracy of SOC estimation. This study investigates a temperature-compensated model for lithiumion polymer batteries that incorporates an extended Kalman filter method to estimate the state of the dynamic nonlinear system and its parameters, from 37 °C to 40 °C at intervals of 1 °C. Both simulation and experimental results indicate that the estimation error can be effectively limited to within ±3%. Through the accurate SOC estimation, the conventional constant current to constant voltage charging strategy is guided in order to reduce the charging time and increase the charging capacity.

10 July 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
Lun-De LiaoLun-De Liao
Lun-De Liao
YWYuhling Wang
Yuhling Wang
YTYung-Chung Tsao
Yung-Chung Tsao
IWI-JAN WANG
I-JAN WANG
JFJhang De Fu
Jhang De Fu
SCSheng-Fu Chen
Sheng-Fu Chen
We present a wearable device built on an Adafruit Circuit Playground Express (CPE) board and integrated with a photoplethysmographic (PPG) optical sensor for heart rate monitoring and multiple embedded sensors for medical applications—in particular, sleep physiological signal monitoring. Our device is portable and lightweight. Due to the microcontroller unit (MCU)-based architecture of the proposed device, it is scalable and flexible. Thus, with the addition of different plug-and-play sensors, it can be used in many applications in different fields. The innovation introduced in this study is that with additional sensors, we can determine whether there are intermediary variables that can be modified to improve our sleep monitoring algorithm. Additionally, although the proposed device has a relatively low cost, it achieves substantially improved performance compared to the commercially available Philips ActiWatch2 wearable device, which has been approved by the Food and Drug Administration (FDA). To assess the reliability of our device, we compared physiological sleep signals recorded simultaneously from volunteers using both our device and ActiWatch2. Motion and light detection data from our device were shown to be correlated to data simultaneously collected using the ActiWatch2, with correlation coefficients of 0.78 and 0.89, respectively. For 7 days of continuous data collection, there was only one instance of a false positive, in which our device detected a sleep interval, while the ActiWatch2 did not. The most important aspect of our research is the use of an open architecture. At the hardware level, general purpose input/output (GPIO), serial peripheral interface (SPI), integrated circuit (I2C), and universal asynchronous receiver-transmitter (UART) standards were used. At the software level, an object-oriented programming methodology was used to develop the system. Because the use of plug-and-play sensors is associated with the risk of adverse outcomes, such as system instability, this study heavily relied on object-oriented programming. Object-oriented programming improves system stability when hardware components are replaced or upgraded, allowing us to change the original system components at a low cost. Therefore, our device is easily scalable and has low commercialization costs. The proposed wearable device can facilitate the long-term tracking of physiological signals in sleep monitoring and related research. The open architecture of our device facilitates collaboration and allows other researchers to adapt our device for use in their own research, which is the main characteristic and contribution of this study.

7 June 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
YWYuhling Wang
Yuhling Wang
JFJhang De Fu
Jhang De Fu
CTChia-Hua Tsai
Chia-Hua Tsai
NCNai-Jung Chiang
Nai-Jung Chiang
CCChiung-Cheng Chuang
Chiung-Cheng Chuang
Lun-De LiaoLun-De Liao
Lun-De Liao
Noninvasive anatomical and functional imaging has become an essential tool to evaluate tissue oxygen saturation dynamics in preclinical or clinical studies of hypoxia. Our dual-wavelength technique for photoacoustic (PA) imaging based on the differential absorbance spectrum of oxyhemoglobin (oxy-Hb) and deoxyhemoglobin (deoxy-Hb) can quantify tissue oxygen saturation using the intrinsic contrast property. PA imaging of tissue oxygen saturation can be used to monitor tumor-related hypoxia, which is a particularly relevant functional parameter of the tumor microenvironment that has a strong influence on tumor aggressiveness. The simultaneous acquisition of anatomical and functional information using dual-modality ultrasound (US) and PA imaging technology enhances the preclinical applicability of the method. Here, the developed dual-modality US/PA system was used to measure relative tissue oxygenation using the dual-wavelength technique. Tissue oxygen saturation was quantified in a pancreatic tumor mouse model. The differences in tissue oxygenation were detected by comparing pancreatic samples from normal and tumor-bearing mice at various time points after implantation. The use of an in vivo pancreatic tumor model revealed changes in hypoxia at various stages of tumor growth. The US/PA imaging data positively correlated with the results of immunohistochemical staining for hypoxia. Thus, our dual-modality US/PA imaging system can be used to reliably assess and monitor hypoxia in pancreatic tumor mouse models. These findings enable the use of a combination of US and PA imaging to acquire anatomical and functional information on tumor growth and to evaluate treatment responses in longitudinal preclinical studies.

27 November 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
HLHe Leng
He Leng
YWYuhling Wang
Yuhling Wang
JFJhang De Fu
Jhang De Fu
TCTsung-Sheng Chu
Tsung-Sheng Chu
CTChia-Hui Tsao
Chia-Hui Tsao
Lun-De LiaoLun-De Liao
Lun-De Liao
Photoacoustic (PA) imaging is an attractive technology for imaging biological tissues because it can capture both functional and structural information with satisfactory spatial resolution. Current commercially available PA imaging systems are limited by their bulky size or inflexible user interface. We present a new handheld real-time ultrasound/photoacoustic imaging system (HARP) consisting of a detachable, high-numerical-aperture (NA) fiber bundle-based illumination system integrated with an array-based ultrasound (US) transducer and a data acquisition platform. In this system, different PA probes can be used for different imaging applications by switching the transducers and the corresponding jackets to combine the fiber pads and transducer into a single probe. The intuitive user interface is a completely programmable MATLAB-based platform. In vitro phantom experiments were conducted to test the imaging performance of the developed PA system. Furthermore, we demonstrated (1) in vivo brain vasculature imaging, (2) in vivo imaging of real-time stimulus-evoked cortical hemodynamic changes during forepaw electrical stimulation, and (3) in vivo imaging of real-time cerebral pharmacokinetics in rats using the developed PA system. The overall purpose of this design concept for a customizable US/PA imaging system is to help overcome the diverse challenges faced by medical researchers performing both preclinical and clinical PA studies.

1 February 2015 in Manual Therapy
Verified
Journal Article
Closed access
KLKuan-Ting Lee
Kuan-Ting Lee
CCChiung-Cheng Chuang
Chiung-Cheng Chuang
CLChien-Hung Lai
Chien-Hung Lai
JYJing-Jhao Ye
Jing-Jhao Ye
CWChien-Lung Wu
Chien-Lung Wu

1 March 2017 in Journal of Pain Research
Verified
Journal Article
Open access
PDF file
JYJing-Jhao Ye
Jing-Jhao Ye
KLKuan-Ting Lee
Kuan-Ting Lee
JLJing-Siang Lin
Jing-Siang Lin
CCChiung-Cheng Chuang
Chiung-Cheng Chuang
Continuously monitoring and efficiently managing pain has become an important issue. However, no study has investigated a change in physiological parameters during the process of pain production/relief. This study modeled the process of pain production/relief using ramped thermal stimulation (no pain: 37°C water, process of pain production: a heating rate of 1°C/min, and subject feels pain: water kept at the painful temperature for each subject, with each segment lasting 10 min). In this duration, the variation of the heat rate variability and photoplethysmography-derived parameters was observed. A total of 40 healthy individuals participated: 30 in the trial group (14 males and 16 females with a mean age of 22.5±1.9 years) and 10 in the control group (7 males and 3 females with a mean age of 22.5±1.3 years). The results showed that the numeric rating scale value was 5.03±1.99 when the subjects felt pain, with a temperature of 43.54±1.70°C. Heart rate, R-R interval, low frequency, high frequency, photoplethysmography amplitude, baseline, and autonomic nervous system state showed significant changes during the pain production process, but these changes differed during the period Segment D (painful temperature 10: min). In summary, the study observed that physiological parameters changed qualitatively during the process of pain production and relief and found that the high frequency, low frequency, and photoplethysmography parameters seemed to have different responses in four situations (no pain, pain production, pain experienced, and pain relief). The trends of these variations may be used as references in the clinical setting for continuously observing pain intensity.