Ileana Radulescu

Dr. Ileana Radulescu

Department of Life and Environmental Physics (DFVM), Horia Hulubei National Institute for Physics and Nuclear Engineering, 30 Reactorului Street, 077125 Magurele, Romania
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2021 in Measurement Science and Technology
Verified
Journal Article
Open access
ARAnnette Röttger
Annette Röttger
SRStefan Röttger
Stefan Röttger
Claudia GrossiClaudia Grossi
Claudia Grossi
AVArturo Vargas
Arturo Vargas
RCRoger Curcoll
Roger Curcoll
VMViacheslav Morosh
Viacheslav Morosh

1 January 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
IRIleana Radulescu
Ileana Radulescu
MCM.R. Calin
M.R. Calin
ALA. Luca
A. Luca
ARAnnette Röttger
Annette Röttger
CGC. Grossi
C. Grossi
MIMihail-Razvan IOAN
Mihail-Razvan IOAN

10 March 2022 in Advances in Geosciences
Verified
Journal Article
Open access
PDF file
SRStefan Röttger
Stefan Röttger
ARAnnette Röttger
Annette Röttger
Claudia GrossiClaudia Grossi
Claudia Grossi
AVArturo Vargas
Arturo Vargas
UKUte Karstens
Ute Karstens
IRIleana Radulescu
Ileana Radulescu
Radon (222Rn) gas is the largest source of public exposure to naturally occurring radioactivity and the identification of radon priority areas is required by the Council Directive 2013/59/Euratom. Radon is also used as a tracer to improve atmospheric transport models and to indirectly estimate greenhouse gas (GHG) fluxes using the Radon Tracer Method (RTM). This method is based on the correlation between atmospheric concentrations of radon and GHG, together with information on the radon flux data. For radiological data, all European countries have installed networks of automatic gamma dose rate monitoring stations and report the real-time information gathered to the European Radiological Data Exchange Platform (EURDEP). So far, atmospheric radon activity concentrations and radon fluxes are not yet reported in EURDEP, nor routinely measured within the European radiological networks although these observations could help to avoid false positives results. Due to above applications, there is a need of building a metrological chain to ensure high quality radon activity concentrations and radon flux measurements. Both climate and radiation protection research communities underline the need for improved traceability in low-level atmospheric radon measurements (Khanbabaee et al., 2021). The EMPIR project 19ENV01 traceRadon 1 is aimed towards providing the necessary measurement infrastructure and transfer standards to fulfil this need. Results of this project are particularly important for improving independent GHG emission estimates that support national reporting under the Paris Agreement on climate change and for the Council Directive 2013/59/Euratom, thus benefitting two large scientific communities. In this paper, early results, such as new activity standard developments and an overview of commercial and research radon monitors are presented and discussed. These results will feed into the traceRadon project with respect to radionuclide metrology in air and its potential for the improvement of the RTM.

1 July 2013 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
IRIleana Radulescu
Ileana Radulescu
ABA.M. Blebea-Apostu
A.M. Blebea-Apostu
RMR.M. Margineanu
R.M. Margineanu
NMN. Mocanu
N. Mocanu

Daniel RábagoDaniel Rábago
Daniel Rábago
LQLuis Santiago Quindos
Luis Santiago Quindos
AVArturo Vargas
Arturo Vargas
CSCarlos Sainz-Fernandez
Carlos Sainz-Fernandez
IRIleana Radulescu
Ileana Radulescu
Claudia GrossiClaudia Grossi
Claudia Grossi
Interlaboratory exercises are a good tool to compare the response of different systems to the same quantity and to identify possible inconsistencies between them. One of the main goals of the EMPIR 19ENV01 traceRadon project is to harmonize radon flux measurements based on different systems and methodologies. In the framework of the traceRadon Project, two radon flux intercomparison campaigns were carried out in October 2021 at high and at low radon source areas. Four institutions participated in the field intercomparison exercises with their own systems. Every system was based on a specific radon monitor (diffusion or pump mode) and an accumulation chamber (with manual or automatic opening). Radon fluxes were calculated by each participant using both exponential and linear fittings of the radon activity concentration measured over time within the accumulation chambers. The results of this study show mainly: (i) the exponential approach is not advisable due to the variability of the radon flux and the leakage of the systems during long-time measurements; (ii) the linear approach should be applied to minimize the measurement period in agreement with the time response and sensitivity of the monitors; (iii) radon flux measured at high radon source areas (radium content of about 800 Bq kg−1) risks being underestimated because of the influence of advective effects; (iv) radon flux measured at low radon source areas (radium content of about 30 Bq kg−1) may present large uncertainties if sensitive radon monitors with pump mode are not used.

15 February 2015 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
IRIleana Radulescu
Ileana Radulescu
MCMihaela Antonina Calin
Mihaela Antonina Calin